Well Water Nerd

Well water in Hampton Falls, New Hampshire

In Hampton Falls, 83% of 36 private wells tested between 2006 and 2020 had arsenic above the New Hampshire guidance level (5 ug/L), according to NH DHHS.

46 private wells tested 2006 to 2020 in state summaries; 5 individual samples from 2 wells, 1986 to 2023. Data refreshed September 3, 2026.

NHDES samples private wells near known or suspected PFAS sources (industrial sites, airports, landfills, fire training areas), and wells with a detection are resampled over time. PFAS shares describe wells that were tested for a reason, not every well in the area.

Separately, a USGS and NHDES statistical model puts the chance that a bedrock well in Hampton Falls exceeds 5 ug/L of arsenic at 67% (as low as 35% in parts of town), based on geology rather than tests.

What homeowner tests found

NH DHHS WISDOM private well summaries: private wells tested and reported to the state, 2006 to 2020. Shares are against the level the state applies to each contaminant, named in the last column; several are stricter than EPA.

ContaminantWells testedAbove state levelMedian95th pctHighestState level
Arsenic3683%12.540.446.65 ug/L
Sodium3376%3219325620 mg/L
Iron3321%1002,3005,700300 ug/L
Chloride4516%33280540250 mg/L
Lead
(stagnant)
3013%0.944.149815 ug/L
Copper
(stagnant)
3010%02.42.81.3 mg/L
Manganese339%0300600300 ug/L
Fluoride460%0.10.40.54 mg/L
Nitrate450%01.77.510 mg/L
Nitrite450%000.21 mg/L
Uranium340%0.72.3530 ug/L

Get the free Hampton Falls well report

One email with the numbers above, what they mean for a home in Hampton Falls, exactly which tests to order, and what treatment fits the local profile. No spam, unsubscribe in one click.

What this means

Among homeowners in Hampton Falls who sent a sample to the state lab, the health-based limits most often exceeded were arsenic (83% of 36 wells), lead (13% of 30 wells), and copper (10% of 30 wells). These are ordinary wells tested by their owners, so the shares are the best available picture of a typical well here, with one caveat: people test more often when they suspect a problem.

Sodium, iron, and chloride exceed the state's advisory level in a sizable share of wells; these are mostly a taste, staining or diet issue rather than a toxicity one.

What to test for in Hampton Falls

  • Volatile organic compounds (VOCs)2 leaking underground storage tank sites on record locally.
  • PFAS2 unlined landfills on record locally.
  • Arsenic83% of 36 local wells tested were above the New Hampshire guidance level.
  • Sodium76% of 33 local wells tested were above the New Hampshire guidance level.
  • Iron21% of 33 local wells tested were above the New Hampshire guidance level.
  • Chloride16% of 45 local wells tested were above the New Hampshire guidance level.
  • Lead13% of 30 local wells tested were above the New Hampshire guidance level.
  • Copper10% of 30 local wells tested were above the New Hampshire guidance level.
  • Manganese9% of 33 local wells tested were above the New Hampshire guidance level.
  • Coliform bacteriaRecommended for every private well, every year.

Wells in Hampton Falls

337 domestic wells in Hampton Falls are on record with the state since 1984. 100% are drilled into bedrock, and the typical well is 245 feet deep (one in ten goes past 500 feet).

In a typical Hampton Falls well, bedrock starts about 31 feet down, the median yield is 15 gallons per minute, 8% of wells yield under 3 gallons per minute and usually need a storage tank.

Bedrock wells are where arsenic, uranium and radon come from: the water sits in fractures in granite and metamorphic rock and picks up whatever the rock carries. That is why testing for those three matters more here than in a dug or gravel well.

92
1980s
98
1990s
86
2000s
42
2010s
18
2020s

Find your own well's report

The state keeps the driller's report for most wells drilled since 1984. It tells you how deep your well is, where bedrock starts, and how much water it makes, which decides what treatment can work.

  1. Open NHDES OneStop and choose Water Well.
  2. Enter your town and one word of your street name. Leave out the house number and the Road or Street part; a short search matches more.
  3. In the results, click Show for your address to see the report: total depth, depth to bedrock, casing, yield in gallons per minute, static water level, and the driller.
  4. Save Results exports the whole list to a spreadsheet.

Reports exist only for wells drilled since January 1984, when reporting became mandatory, and street names are as they were when the well was drilled.

Contamination sources on record in Hampton Falls

NHDES records 2 leaking underground storage tank sites, 2 unlined landfills, and 6 reported spills and releases in Hampton Falls, among 67 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.

2
leaking underground storage tank sitesGasoline and heating oil that leaked from tanks move through groundwater as benzene, MTBE and other volatile organic compounds.
2
unlined landfillsOlder unlined landfills are a leading source of PFAS, VOCs and metals in nearby wells.
6
reported spills and releasesMost spills are fuel; a few are solvents or chemicals that reach the water table.
6
registered underground storage tank sitesRegistered tanks are regulated and inspected; they matter most when they are old or near a shallow well.
23
locally identified potential contamination sourcesTowns inventory these (vehicle repair, labs, salt piles, farms) when they draw wellhead protection maps.
27
other remediation projects
1
other solid waste facility

Treatment that fits the local profile

Arsenic
Point-of-use reverse osmosis; Adsorptive media (iron-based) whole-house; Anion exchange
Lead
Point-of-use reverse osmosis; Certified lead-removal carbon filter; Neutralizing filter to raise pH and stop leaching
Copper
Neutralizing filter to raise pH; Point-of-use reverse osmosis
Sodium
Point-of-use reverse osmosis; Distillation
Iron
Oxidizing filter whole-house; Water softener (low levels); Aeration plus filtration
Fluoride
Point-of-use reverse osmosis; Activated alumina; Distillation

Book a free water test in Hampton Falls

A licensed local water treatment company tests your tap water in your home, walks you through the numbers, and quotes treatment only if something needs fixing. Free, about 30 minutes, no obligation.

What are you worried about?

The test is free and there is no obligation. Your details go only to the company named above, and we log the time and address of this request.

Common questions

How deep are wells in Hampton Falls?

The typical domestic well in Hampton Falls is 245 feet deep, based on 337 wells reported to the state since 1984. One in ten is deeper than 500 feet. 100% are drilled into bedrock.

Is there arsenic in well water in Hampton Falls?

Arsenic was detected in 100% of 4 public well samples in Hampton Falls, and 100% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.

How high is radon in well water in Hampton Falls?

The median radon level across 1 public samples in Hampton Falls was 2,600 pCi/L, with a high of 2,600 pCi/L. New Hampshire recommends treatment above 2,000 pCi/L.

How often should I test a private well in Hampton Falls?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Sources

  • USGS Water Quality Portal: 32 samples in Hampton Falls. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
  • NHDES PFAS sampling: 4 samples in Hampton Falls. PFAS results for private wells from the New Hampshire Department of Environmental Services Environmental Monitoring Database. Retrieved September 3, 2026.
  • NH DHHS WISDOM private well summaries: summaries for 11 contaminants in Hampton Falls, up to 46 wells each. Town summaries of private well tests run by the New Hampshire Public Health Laboratories, published by NH DHHS through the WISDOM environmental public health tracking portal. Exceedance shares use New Hampshire guidance levels, which are stricter than EPA for arsenic (5 ug/L), manganese (0.3 mg/L), radon (2,000 pCi/L) and sodium (20 mg/L). Statistics for small counts are suppressed (*). Retrieved September 3, 2026.
  • NHDES Water Well Inventory: 362 well records in Hampton Falls, 337 domestic. Well construction records reported to the New Hampshire Department of Environmental Services Water Well Board. Only aggregates are shown; owner names and addresses are never stored. Retrieved September 3, 2026.
  • NHDES OneStop regulated sites: 67 regulated sites located in Hampton Falls. Remediation sites, underground storage tanks, solid waste facilities and potential contamination sources from the New Hampshire Department of Environmental Services OneStop database. Retrieved September 3, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.