Well Water Nerd

Well water in Concord, New Hampshire

In Concord, 46% of 391 private wells tested between 2006 and 2020 had arsenic above the New Hampshire guidance level (5 ug/L), according to NH DHHS.

391 private wells tested 2006 to 2020 in state summaries; 72 individual samples from 48 wells, 1966 to 2022. Data refreshed September 3, 2026.

Separately, a USGS and NHDES statistical model puts the chance that a bedrock well in Concord exceeds 5 ug/L of arsenic at 35% (as low as 9% in parts of town), based on geology rather than tests.

What homeowner tests found

NH DHHS WISDOM private well summaries: private wells tested and reported to the state, 2006 to 2020. Shares are against the level the state applies to each contaminant, named in the last column; several are stricter than EPA.

ContaminantWells testedAbove state levelMedian95th pctHighestState level
Radon18163%3,50045,00070,5462,000 pCi/L
Arsenic39146%3.61695985 ug/L
Sodium33538%16.41082,18620 mg/L
Iron33718%1001,40055,000300 ug/L
Lead
(stagnant)
31412%1.427.712615 ug/L
Copper
(stagnant)
3149%02.5101.3 mg/L
Manganese3406%04004,400300 ug/L
Uranium3366%136.511030 ug/L
Chloride3894%6.22083,300250 mg/L
Nitrate388<1%03.42110 mg/L
Fluoride384<1%0.62.64.94 mg/L
Nitrite3880%000.21 mg/L

What individual samples found

Each row summarizes every public sample for that contaminant inside Concord. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.

ContaminantSamplesDetectedAbove limitMedianHighestLimit
Arsenic
1986 to 2022
2759%30%1.730010 ug/L
EPA limit
Fluoride
1966 to 2018
5983%2%0.44.54 mg/L
EPA limit
Nitrate
1966 to 2018
7233%0%04.810 mg/L
EPA limit
Lead
1986 to 2022
2143%0%08.0415 ug/L
EPA limit
Copper
1988 to 2022
1889%0%0.0040.4161.3 mg/L
EPA limit
Uranium
2000 to 2022
1741%0%013.330 ug/L
EPA limit
Chloride
1966 to 2018
6574%no limit2.2435250 mg/L
nuisance level
Manganese
1966 to 2022
6475%no limit302,820300 ug/L
health guideline
Sodium
1966 to 2018
5296%no limit11.818420 mg/L
health guideline
Radon
1986 to 2000
20100%no limit24,050215,0002,000 pCi/L
health guideline

Sampled fewer than 10 times, too few to summarize: Radium (226 + 228) (4), E. coli (9), Iron (5).

Get the free Concord well report

One email with the numbers above, what they mean for a home in Concord, exactly which tests to order, and what treatment fits the local profile. No spam, unsubscribe in one click.

What this means

Among homeowners in Concord who sent a sample to the state lab, the health-based limits most often exceeded were arsenic (46% of 391 wells), lead (12% of 314 wells), and copper (9% of 314 wells). These are ordinary wells tested by their owners, so the shares are the best available picture of a typical well here, with one caveat: people test more often when they suspect a problem.

Radon was above the New Hampshire guidance level of 2,000 pCi/L in 63% of 181 wells. Radon in water matters because it moves into indoor air during showers and laundry.

Sodium and iron exceed the state's advisory level in a sizable share of wells; these are mostly a taste, staining or diet issue rather than a toxicity one.

What to test for in Concord

  • Volatile organic compounds (VOCs)69 leaking underground storage tank sites on record locally.
  • PFAS5 unlined landfills on record locally.
  • Metals panel32 hazardous waste sites on record locally.
  • Radon63% of 181 local wells tested were above the New Hampshire guidance level.
  • Sodium38% of 335 local wells tested were above the New Hampshire guidance level.
  • Iron18% of 337 local wells tested were above the New Hampshire guidance level.
  • Lead12% of 314 local wells tested were above the New Hampshire guidance level.
  • Copper9% of 314 local wells tested were above the New Hampshire guidance level.
  • Manganese6% of 340 local wells tested were above the New Hampshire guidance level.
  • Uranium6% of 336 local wells tested were above the New Hampshire guidance level.
  • Chloride4% of 389 local wells tested were above the New Hampshire guidance level.

Wells in Concord

870 domestic wells in Concord are on record with the state since 1984. 98% are drilled into bedrock, and the typical well is 365 feet deep (one in ten goes past 600 feet).

In a typical Concord well, bedrock starts about 53 feet down, the median yield is 7 gallons per minute, 17% of wells yield under 3 gallons per minute and usually need a storage tank.

Bedrock wells are where arsenic, uranium and radon come from: the water sits in fractures in granite and metamorphic rock and picks up whatever the rock carries. That is why testing for those three matters more here than in a dug or gravel well.

185
1980s
125
1990s
291
2000s
173
2010s
94
2020s

Find your own well's report

The state keeps the driller's report for most wells drilled since 1984. It tells you how deep your well is, where bedrock starts, and how much water it makes, which decides what treatment can work.

  1. Open NHDES OneStop and choose Water Well.
  2. Enter your town and one word of your street name. Leave out the house number and the Road or Street part; a short search matches more.
  3. In the results, click Show for your address to see the report: total depth, depth to bedrock, casing, yield in gallons per minute, static water level, and the driller.
  4. Save Results exports the whole list to a spreadsheet.

Reports exist only for wells drilled since January 1984, when reporting became mandatory, and street names are as they were when the well was drilled.

Contamination sources on record in Concord

NHDES records 69 leaking underground storage tank sites, 5 unlined landfills, 32 hazardous waste sites, and 31 reported spills and releases in Concord, among 489 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.

69
leaking underground storage tank sitesGasoline and heating oil that leaked from tanks move through groundwater as benzene, MTBE and other volatile organic compounds.
5
unlined landfillsOlder unlined landfills are a leading source of PFAS, VOCs and metals in nearby wells.
32
hazardous waste sitesSolvents, degreasers and metals from industrial sites can travel far in fractured bedrock.
31
reported spills and releasesMost spills are fuel; a few are solvents or chemicals that reach the water table.
153
registered underground storage tank sitesRegistered tanks are regulated and inspected; they matter most when they are old or near a shallow well.
18
locally identified potential contamination sourcesTowns inventory these (vehicle repair, labs, salt piles, farms) when they draw wellhead protection maps.
174
other remediation projects
7
other solid waste facilities

Treatment that fits the local profile

Arsenic
Point-of-use reverse osmosis; Adsorptive media (iron-based) whole-house; Anion exchange
Lead
Point-of-use reverse osmosis; Certified lead-removal carbon filter; Neutralizing filter to raise pH and stop leaching
Copper
Neutralizing filter to raise pH; Point-of-use reverse osmosis
Uranium
Point-of-use reverse osmosis; Anion exchange; Whole-house anion exchange
Radon
Aeration (bubble-up or diffused) whole-house; Granular activated carbon whole-house (lower levels only)
Fluoride
Point-of-use reverse osmosis; Activated alumina; Distillation

Book a free water test in Concord

A licensed local water treatment company tests your tap water in your home, walks you through the numbers, and quotes treatment only if something needs fixing. Free, about 30 minutes, no obligation.

What are you worried about?

The test is free and there is no obligation. Your details go only to the company named above, and we log the time and address of this request.

Common questions

How deep are wells in Concord?

The typical domestic well in Concord is 365 feet deep, based on 870 wells reported to the state since 1984. One in ten is deeper than 600 feet. 98% are drilled into bedrock.

Is there arsenic in well water in Concord?

Arsenic was detected in 59% of 27 public well samples in Concord, and 30% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.

How high is radon in well water in Concord?

The median radon level across 20 public samples in Concord was 24,050 pCi/L, with a high of 215,000 pCi/L. New Hampshire recommends treatment above 2,000 pCi/L.

How often should I test a private well in Concord?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Sources

  • USGS Water Quality Portal: 433 samples in Concord. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
  • NH DHHS WISDOM private well summaries: summaries for 12 contaminants in Concord, up to 391 wells each. Town summaries of private well tests run by the New Hampshire Public Health Laboratories, published by NH DHHS through the WISDOM environmental public health tracking portal. Exceedance shares use New Hampshire guidance levels, which are stricter than EPA for arsenic (5 ug/L), manganese (0.3 mg/L), radon (2,000 pCi/L) and sodium (20 mg/L). Statistics for small counts are suppressed (*). Retrieved September 3, 2026.
  • NHDES Water Well Inventory: 1,062 well records in Concord, 870 domestic. Well construction records reported to the New Hampshire Department of Environmental Services Water Well Board. Only aggregates are shown; owner names and addresses are never stored. Retrieved September 3, 2026.
  • NHDES OneStop regulated sites: 489 regulated sites located in Concord. Remediation sites, underground storage tanks, solid waste facilities and potential contamination sources from the New Hampshire Department of Environmental Services OneStop database. Retrieved September 3, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.