Well Water Nerd

Well water in Pecos County, Texas

1in12

Testing recommended

tested well samples in Pecos County exceeded the EPA limit for nitrate (10 mg/L), based on public data from Texas Water Development Board Groundwater Database and USGS Water Quality Portal.

The strongest signal is gross alpha: 13% of 15 local samples were above the limit, too few samples to carry the headline but first on the test list below.

1,023 test results across 14 contaminants from at least 127 wells, 1946 to 2026; nitrate has the most at 175. Data refreshed September 15, 2026.

Compiled by Nick at Well Water Nerd from public records. How these pages are built

TWDB samples an ambient monitoring network of wells on a rotation, so these describe aquifers, not a survey of homeowners' tests.

An estimated 3,820 people in Pecos County get their drinking water from a private well, per USGS 2015 county water use. That is about 24% of residents.

Separately, the USGS national arsenic model estimates that 4% of the 3,820 people on private wells in Pecos County draw water above 10 ug/L (the model's range is 3% to 5%), from geology and well depth rather than local tests.

What individual samples found

Each row summarizes every public sample for that contaminant inside Pecos County. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.

ContaminantAbove limitSamplesDetectedMedianHighestLimit
Gross alpha
1993 to 2023
1580%654.915 pCi/L
EPA limit
Nitrate
1987 to 2026
17579%1.55310 mg/L
EPA limit
Uranium
2010 to 2026
5198%3.539.830 ug/L
EPA limit
Arsenic
1993 to 2026
7551%0.0570.310 ug/L
EPA limit
Fluoride
1956 to 2026
156100%1.454.14 mg/L
EPA limit
Copper
1993 to 2026
4457%0.0010.0291.3 mg/L
EPA limit
Lead
1993 to 2026
447%07.1415 ug/L
EPA limit
Radium (226 + 228)
2010 to 2023
2673%0.65545 pCi/L
EPA limit
Chloride
1946 to 2026
no limit17499%22853,600250 mg/L
nuisance level
Sodium
1946 to 2026
no limit98100%1921,10020 mg/L
health guideline
Iron
1972 to 2026
no limit8259%10.723,600300 ug/L
nuisance level
Manganese
1993 to 2026
no limit7769%1.62,660300 ug/L
health guideline

Sampled fewer than 10 times, too few to summarize: E. coli (3), Radon (3).

Over time

Share of samples above the limit by period. A cell needs ten samples to show; a comparison needs twenty in each period. Later periods sample fewer wells, and often the ones already known to have a problem.

Contaminantbefore 20002000s2010s2020s
Nitrate9%70 samples0%18 samples9%81 samplesn/a
Fluoride1%87 samples0%16 samples0%47 samplesn/a
Arsenic0%10 samples0%14 samples2%45 samplesn/a
Copper0%10 samples0%14 samples0%14 samplesn/a
Lead0%10 samples0%14 samples0%14 samplesn/a

Nitrate, fluoride have held within a few points between the two most recent periods with enough samples.

Closer than the county

See the sampled wells near your address

The same records, drawn around one point: which wells within a few miles were sampled and what they found, how deep the wells next to you were drilled, and any leaking tank or cleanup site within a mile.

Check my address

What this means

The contaminants most often above their limit here are gross alpha (13% of 15 samples), nitrate (9% of 175 samples), and uranium (2% of 51 samples). A well next door can differ sharply from yours because bedrock fractures, well depth and plumbing all matter, so these rates describe the area, not your tap.

Chloride, Iron, and Manganese are widespread in local groundwater. They are mainly a staining and taste problem, but high manganese also carries a health advisory for infants.

What to test for in Pecos County

  1. 1
    Gross alpha
    13% of 15 local samples were above the limit.
  2. 2
    Nitrate
    9% of 175 local samples were above the limit.
  3. 3
    Uranium
    2% of 51 local samples were above the limit.
  4. 4
    Arsenic
    1% of 75 local samples were above the limit.
  5. 5
    Fluoride
    <1% of 156 local samples were above the limit.
  6. 6
    Coliform bacteria
    Recommended for every private well, every year.
  7. 7
    Radon
    Median local reading is 400 pCi/L.
  8. 8
    Volatile organic compounds (VOCs)
    42 leaking underground storage tank sites on record locally.

Test your Pecos County well for gross alpha, nitrate and uranium

Certified lab analysis of your own tap water, bottles and prepaid return shipping included. The Essential well panel covers arsenic, uranium, nitrate, lead, copper, manganese, iron, sodium and bacteria; radon and PFAS are add-ons.

Order the Tap Score well water test kit, from $209Already tested? Upload the report

Just want bacteria checked first? Tap Score coliform and E. coli test, $99. Coliform and E. coli are the tests every well needs every year.

Want a quick look before paying for a lab? Home well water test strips on Amazon check hardness, iron, pH and nitrate in minutes. They are a screen, not a result: arsenic, bacteria, uranium and PFAS need a certified lab.

Affiliate links: the merchant pays us a commission and the price is the same for you. It does not change what the data above says. As an Amazon Associate we earn from qualifying purchases.

Where to get a well tested in Texas: certified labs, state programs and prices.

Already have results back? Get your lab report read against the Pecos County numbers, $29. Every line explained, ranked by what matters, with the fix for each.

The rock under Pecos County

Pecos River Basin alluvial aquifer

Unconsolidated sand and gravel. Wells in sand and gravel are usually shallow and productive, and they recharge quickly from the surface. That makes them the most exposed to nitrate, bacteria and anything spilled nearby, and the least likely to carry arsenic or radon from the rock.

Classification from the USGS Principal Aquifers of the United States (national map, 2003 edition, GIS release 2015), read at the county centroid. A single well can sit in a different unit, especially near a boundary.

Official help in Texas

Two places to start that are not selling anything: the state program that answers private well questions, and its list of labs certified to run drinking water tests. A certified lab is the difference between a result you can act on and a number.

Contamination sources on record in Pecos County

TCEQ records 42 leaking underground storage tank sites in Pecos County, among 48 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.

42
leaking underground storage tank sitesGasoline and heating oil that leaked from tanks move through groundwater as benzene, MTBE and other volatile organic compounds.
6
lined landfills and transfer facilities

Treatment that fits the local profile

Gross alpha

Point-of-use reverse osmosis; Water softener (cation exchange) for radium; Anion exchange for uranium

Nitrate

Point-of-use reverse osmosis; Anion exchange; Distillation

Uranium

Point-of-use reverse osmosis; Anion exchange; Whole-house anion exchange

Arsenic

Point-of-use reverse osmosis; Adsorptive media (iron-based) whole-house; Anion exchange

Fluoride

Point-of-use reverse osmosis; Activated alumina; Distillation

Systems we would look at first

Some links below are affiliate links. If you buy through one, the merchant pays us a commission at no extra cost to you. It does not change which products we list or what the data says.

For gross alpha

Under-sink reverse osmosis system

under-sink or countertop, about $300

Look for NSF/ANSI 58 certification listing the contaminant you need removed.

For nitrate

Aquasana SmartFlow reverse osmosis

under-sink or countertop, about $225

Certified to NSF/ANSI 58 and 53 to reduce arsenic (96%, pentavalent), fluoride (90%), lead (99%), nitrate, nitrite and PFOA/PFOS at the kitchen tap, with a remineralizer.

For uranium

Whole-house arsenic and uranium filter

whole-house, at the point of entry, about $2,500

Adsorptive iron-based media; sized to your well yield.

Free, no obligation

Get on the list for a free in-home water test in Pecos County

No water treatment company serves Pecos County through Well Water Nerd yet. We are signing licensed companies on county by county: they test at your tap for free, walk you through the numbers, and quote treatment only if something needs fixing. Leave your details and you are first in line. Nothing is shared until a company joins for Pecos County, and you get an email naming it first.

What are you worried about?

The test is free and there is no obligation. No company is named yet; your details stay with us until one joins for your area, and we log the time and address of this request.

Common questions

Is there arsenic in well water in Pecos County?

Arsenic was detected in 51% of 75 public well samples in Pecos County, and 1% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.

How often should I test a private well in Pecos County?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Counties near Pecos County

Closest first. Groundwater does not stop at a line on a map, so the next county over is a fair second opinion.

Want the numbers themselves? Download the Texas dataset as CSV, every county and town, with the sources named.

Sources

  • Texas Water Development Board Groundwater Database: 604 samples in Pecos County. Water quality samples from the Texas Water Development Board Groundwater Database, collected by TWDB, groundwater conservation districts and cooperators. Retrieved September 9, 2026.
  • USGS Water Quality Portal: 419 samples in Pecos County. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
  • USGS national arsenic model (Ayotte 2017): estimated share of 3,820 people on private wells in Pecos County above 10 ug/L of arsenic, from geology, well depth and land use. County estimates of domestic well users with arsenic above 10 ug/L from the USGS national logistic regression model (Ayotte, Medalie and Qi, 2017), with private well population from the USGS 2015 county water-use compilation (Dieter and others, 2018). Retrieved September 15, 2026.
  • TCEQ regulated sites: 48 regulated sites located in Pecos County. Leaking petroleum storage tank sites, state Superfund sites and municipal solid waste landfills from the Texas Commission on Environmental Quality. Retrieved September 9, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.