Well Water Nerd

Well water in Reagan County, Texas

In Reagan County, 13% of 32 tested well samples exceeded the EPA limit for radium (226 + 228) (5 pCi/L), based on public data from Texas Water Development Board Groundwater Database and USGS Water Quality Portal.

124 individual samples from 81 wells, 1960 to 2023. Data refreshed September 9, 2026.

TWDB samples an ambient monitoring network of wells on a rotation, so these describe aquifers, not a survey of homeowners' tests.

What individual samples found

Each row summarizes every public sample for that contaminant inside Reagan County. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.

ContaminantSamplesDetectedAbove limitMedianHighestLimit
Gross alpha
1993 to 2023
2450%33%2.464715 pCi/L
EPA limit
Uranium
2007 to 2023
2488%29%16.610330 ug/L
EPA limit
Radium (226 + 228)
2010 to 2023
3278%13%1.1522.45 pCi/L
EPA limit
Nitrate
1993 to 2023
5890%10%3.7563.810 mg/L
EPA limit
Arsenic
1987 to 2023
5949%8%021.310 ug/L
EPA limit
Fluoride
1960 to 2023
124100%<1%2.44.954 mg/L
EPA limit
Lead
1993 to 2023
583%0%01.915 ug/L
EPA limit
Copper
1993 to 2023
5890%0%0.0030.0281.3 mg/L
EPA limit
Chloride
1960 to 2023
124100%no limit1191,890250 mg/L
nuisance level
Sodium
1960 to 2023
124100%no limit2001,13020 mg/L
health guideline
Manganese
1966 to 2023
6067%no limit3.95169300 ug/L
health guideline
Iron
1987 to 2023
5932%no limit02,780300 ug/L
nuisance level

Sampled fewer than 10 times, too few to summarize: E. coli (1), Radon (1).

Get the free Reagan County well report

One email with the numbers above, what they mean for a home in Reagan County, exactly which tests to order, and what treatment fits the local profile. No spam, unsubscribe in one click.

What this means

The contaminants most often above their limit here are gross alpha (33% of 24 samples), uranium (29% of 24 samples), and radium (226 + 228) (13% of 32 samples). A well next door can differ sharply from yours because bedrock fractures, well depth and plumbing all matter, so these rates describe the area, not your tap.

Chloride and Manganese are widespread in local groundwater. They are mainly a staining and taste problem, but high manganese also carries a health advisory for infants.

What to test for in Reagan County

  • Volatile organic compounds (VOCs)20 leaking underground storage tank sites on record locally.
  • Gross alpha33% of 24 local samples were above the limit.
  • Uranium29% of 24 local samples were above the limit.
  • Radium (226 + 228)13% of 32 local samples were above the limit.
  • Nitrate10% of 58 local samples were above the limit.
  • Arsenic8% of 59 local samples were above the limit.
  • Fluoride<1% of 124 local samples were above the limit.
  • Coliform bacteriaRecommended for every private well, every year.

Contamination sources on record in Reagan County

TCEQ records 20 leaking underground storage tank sites in Reagan County, among 21 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.

20
leaking underground storage tank sitesGasoline and heating oil that leaked from tanks move through groundwater as benzene, MTBE and other volatile organic compounds.
1
lined landfill or transfer facility

Treatment that fits the local profile

Gross alpha
Point-of-use reverse osmosis; Water softener (cation exchange) for radium; Anion exchange for uranium
Uranium
Point-of-use reverse osmosis; Anion exchange; Whole-house anion exchange
Radium (226 + 228)
Water softener (cation exchange); Point-of-use reverse osmosis
Nitrate
Point-of-use reverse osmosis; Anion exchange; Distillation
Arsenic
Point-of-use reverse osmosis; Adsorptive media (iron-based) whole-house; Anion exchange

Get your Reagan County water tested at home

A licensed local water treatment company tests your tap water in your home, walks you through the numbers, and quotes treatment only if something needs fixing. Free, about 30 minutes, no obligation. Tell us what you need and we match you with a company that serves Reagan County.

What are you worried about?

The test is free and there is no obligation. Your details go only to the company named above, and we log the time and address of this request.

Common questions

Is there arsenic in well water in Reagan County?

Arsenic was detected in 49% of 59 public well samples in Reagan County, and 8% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.

How high is radon in well water in Reagan County?

The median radon level across 1 public samples in Reagan County was 310 pCi/L, with a high of 310 pCi/L. New Hampshire recommends treatment above 2,000 pCi/L.

How often should I test a private well in Reagan County?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Sources

  • Texas Water Development Board Groundwater Database: 801 samples in Reagan County. Water quality samples from the Texas Water Development Board Groundwater Database, collected by TWDB, groundwater conservation districts and cooperators. Retrieved September 9, 2026.
  • USGS Water Quality Portal: 5 samples in Reagan County. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
  • TCEQ regulated sites: 21 regulated sites located in Reagan County. Leaking petroleum storage tank sites, state Superfund sites and municipal solid waste landfills from the Texas Commission on Environmental Quality. Retrieved September 9, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.