Well Water Nerd

Well water in Susquehanna County, Pennsylvania

1in3

Testing strongly recommended

private wells tested between 2008 and 2025 in Susquehanna County had total coliform above the EPA limit (0 MPN/100mL), according to the Penn State water testing lab.

351 private wells tested 2008 to 2025 in state summaries; 1,055 test results across 15 contaminants from at least 122 wells, 1930 to 2026; nitrate has the most at 164. Data refreshed September 16, 2026.

Compiled by Nick at Well Water Nerd from public records. How these pages are built

These are samples homeowners paid to send to the Penn State lab, often because of a suspected problem, so shares above the limit run higher than a random survey would find.

An estimated 31,518 people in Susquehanna County get their drinking water from a private well, per USGS 2015 county water use. That is about 76% of residents.

Separately, the USGS national arsenic model estimates that 3% of the 31,518 people on private wells in Susquehanna County draw water above 10 ug/L (the model's range is 2% to 4%), from geology and well depth rather than local tests.

What homeowner tests found

Penn State Agricultural Analytical Services Lab drinking water summaries: private wells tested and reported to the state, 2008 to 2025. Shares are against the level the state applies to each contaminant, named in the last column; several are stricter than EPA.

ContaminantAbove state levelWells testedMedian95th pctHighestState level
Total coliform3512010 MPN/100mL
Manganese128101,68050 ug/L
Iron13020017,700300 ug/L
E. coli3512010 MPN/100mL
Lead
(first draw)
939215 ug/L
Copper1160.011.961.3 mg/L
Arsenic1401510 ug/L
Chloride1363.3127250 mg/L
Nitrate
+ nitrite as N
1290.55.310 mg/L
Sodium517.73141

What individual samples found

Each row summarizes every public sample for that contaminant inside Susquehanna County. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.

ContaminantAbove limitSamplesDetectedMedianHighestLimit
Arsenic
1973 to 2026
5670%0.5352810 ug/L
EPA limit
Nitrate
1930 to 2026
16474%0.1152610 mg/L
EPA limit
Fluoride
1955 to 2026
11898%0.1052.94 mg/L
EPA limit
Lead
1982 to 2026
5971%00.915 ug/L
EPA limit
Copper
1973 to 2026
4457%0.0010.041.3 mg/L
EPA limit
Uranium
2014 to 2025
3792%0.823.5430 ug/L
EPA limit
Chloride
1930 to 2026
no limit146100%3324250 mg/L
nuisance level
Iron
1930 to 2026
no limit13991%94.647,500300 ug/L
nuisance level
Sodium
1930 to 2026
no limit137100%1322420 mg/L
health guideline
Manganese
1955 to 2026
no limit13292%504,600300 ug/L
health guideline

Sampled fewer than 10 times, too few to summarize: E. coli (7), PFOS (3), PFOA (3), Radium (226 + 228) (2), Radon (8).

Over time

Share of samples above the limit by period. A cell needs ten samples to show; a comparison needs twenty in each period. Later periods sample fewer wells, and often the ones already known to have a problem.

Contaminantbefore 20002000s2010s2020s
Nitrate2%95 samplesn/a0%42 samples0%25 samples
Fluoride0%75 samplesn/a0%23 samples0%19 samples
Lead0%16 samplesn/a0%24 samples0%19 samples
Arsenicn/an/a4%28 samples0%19 samples
Coppern/an/a0%24 samples0%19 samples
Uraniumn/an/a0%27 samples0%10 samples

Nitrate, fluoride have held within a few points between the two most recent periods with enough samples.

Closer than the county

See the sampled wells near your address

The same records, drawn around one point: which wells within a few miles were sampled and what they found, how deep the wells next to you were drilled, and any leaking tank or cleanup site within a mile.

Check my address

What this means

Among homeowners in Susquehanna County who sent a sample to the state lab, the health-based limits most often exceeded were total coliform (40% of 351 wells), E. coli (8% of 351 wells), and lead (2% of 93 wells). These are ordinary wells tested by their owners, so the shares are the best available picture of a typical well here, with one caveat: people test more often when they suspect a problem.

Manganese and iron exceed the state's advisory level in a sizable share of wells; these are mostly a taste, staining or diet issue rather than a toxicity one.

What to test for in Susquehanna County

  1. 1
    Total coliform
    40% of 351 local wells tested were above the EPA limit.
  2. 2
    E. coli
    8% of 351 local wells tested were above the EPA limit.
  3. 3
    Arsenic
    7% of 56 local samples were above the limit.
  4. 4
    Lead
    2% of 93 local wells tested were above the EPA limit.
  5. 5
    Copper
    2% of 116 local wells tested were above the EPA limit.
  6. 6
    Nitrate
    1% of 164 local samples were above the limit.
  7. 7
    Radon
    Median local reading is 1,675 pCi/L.
  8. 8
    Manganese
    25% of 128 local wells tested were above the EPA secondary standard.

Test your Susquehanna County well for total coliform, E. coli and arsenic

Certified lab analysis of your own tap water, bottles and prepaid return shipping included. The Essential well panel covers arsenic, uranium, nitrate, lead, copper, manganese, iron, sodium and bacteria; radon and PFAS are add-ons.

Order the Tap Score well water test kit, from $209Already tested? Upload the report

Just want bacteria checked first? Tap Score coliform and E. coli test, $99. Coliform and E. coli are the tests every well needs every year.

Want a quick look before paying for a lab? Home well water test strips on Amazon check hardness, iron, pH and nitrate in minutes. They are a screen, not a result: arsenic, bacteria, uranium and PFAS need a certified lab.

Affiliate links: the merchant pays us a commission and the price is the same for you. It does not change what the data above says. As an Amazon Associate we earn from qualifying purchases.

Where to get a well tested in Pennsylvania: certified labs, state programs and prices.

Already have results back? Get your lab report read against the Susquehanna County numbers, $29. Every line explained, ranked by what matters, with the fix for each.

Wells in Susquehanna County

2,866 domestic wells in Susquehanna County are on record with the state. 99% are drilled into bedrock, and the typical well is 255 feet deep (one in ten goes past 480 feet).

In a typical Susquehanna County well, bedrock starts about 45 feet down, the median yield is 12 gallons per minute, 6% of wells yield under 3 gallons per minute and usually need a storage tank.

Bedrock wells are where arsenic, uranium and radon come from: the water sits in fractures in granite and metamorphic rock and picks up whatever the rock carries. That is why testing for those three matters more here than in a dug or gravel well.

Find your own well's report

The state keeps the driller's report for most wells drilled since 1984. It tells you how deep your well is, where bedrock starts, and how much water it makes, which decides what treatment can work.

  1. Open PaGWIS (Pennsylvania Geological Survey) and choose Water Well.
  2. The record lists depth, depth to bedrock, yield and use; drillers have reported new wells to the state since 1966.

Pennsylvania has no private well construction standard and does not require testing, so many older wells have no record at all.

The rock under Susquehanna County

Not a principal aquifer

The USGS map places this area outside any principal aquifer, which usually means wells here draw from fractured bedrock or thin local deposits rather than a large regional aquifer. Bedrock wells of that kind are where arsenic, radon and uranium turn up, and yields vary from well to well.

Classification from the USGS Principal Aquifers of the United States (national map, 2003 edition, GIS release 2015), read at the county centroid. A single well can sit in a different unit, especially near a boundary.

Official help in Pennsylvania

Two places to start that are not selling anything: the state program that answers private well questions, and its list of labs certified to run drinking water tests. A certified lab is the difference between a result you can act on and a number.

Treatment that fits the local profile

Total coliform

Inspect and repair the well cap and casing, then shock chlorinate and retest; UV disinfection whole-house; Chlorination system

E. coli

Shock chlorination and fix the well cap or casing; UV disinfection whole-house; Chlorination system

Manganese

Oxidizing filter (greensand, birm) whole-house; Water softener (low levels); Point-of-use reverse osmosis

Iron

Oxidizing filter whole-house; Water softener (low levels); Aeration plus filtration

Arsenic

Point-of-use reverse osmosis; Adsorptive media (iron-based) whole-house; Anion exchange

Nitrate

Point-of-use reverse osmosis; Anion exchange; Distillation

Systems we would look at first

Some links below are affiliate links. If you buy through one, the merchant pays us a commission at no extra cost to you. It does not change which products we list or what the data says.

For total coliform

Aquasana Rhino Well Water with UV

whole-house, at the point of entry, about $2,871

Whole-house system built for wells: sediment pre-filter, KDF and carbon, and a UV lamp rated to kill 99.99% of bacteria and viruses. It does not remove arsenic, nitrate, uranium or radon.

For E. coli

UV disinfection system

whole-house, at the point of entry, about $900

Fix the well cap and casing first; UV keeps bacteria from returning.

For manganese

Iron and manganese oxidizing filter

whole-house, at the point of entry, about $1,800

Air-injection or greensand media; fixes staining at the source.

For arsenic

Under-sink reverse osmosis system

under-sink or countertop, about $300

Look for NSF/ANSI 58 certification listing the contaminant you need removed.

For arsenic

Whole-house arsenic and uranium filter

whole-house, at the point of entry, about $2,500

Adsorptive iron-based media; sized to your well yield.

For arsenic

Aquasana SmartFlow reverse osmosis

under-sink or countertop, about $225

Certified to NSF/ANSI 58 and 53 to reduce arsenic (96%, pentavalent), fluoride (90%), lead (99%), nitrate, nitrite and PFOA/PFOS at the kitchen tap, with a remineralizer.

Free, no obligation

Get on the list for a free in-home water test in Susquehanna County

No water treatment company serves Susquehanna County through Well Water Nerd yet. We are signing licensed companies on county by county: they test at your tap for free, walk you through the numbers, and quote treatment only if something needs fixing. Leave your details and you are first in line. Nothing is shared until a company joins for Susquehanna County, and you get an email naming it first.

What are you worried about?

The test is free and there is no obligation. No company is named yet; your details stay with us until one joins for your area, and we log the time and address of this request.

Common questions

How deep are wells in Susquehanna County?

The typical domestic well in Susquehanna County is 255 feet deep, based on 2,866 wells reported to the state. One in ten is deeper than 480 feet. 99% are drilled into bedrock.

Is there arsenic in well water in Susquehanna County?

Arsenic was detected in 70% of 56 public well samples in Susquehanna County, and 7% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.

How often should I test a private well in Susquehanna County?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Towns in Susquehanna County

39 towns have fewer than 30 public samples and are included in the Susquehanna County totals above rather than shown separately: Apolacon township, Ararat township, Auburn township, Bridgewater township, Brooklyn township, Choconut township, Clifford township, Dimock township, Forest City borough, Forest Lake township, Franklin township, Friendsville borough, Gibson township, Great Bend borough, Great Bend township, Hallstead borough, Harford township, Harmony township, Herrick township, Hop Bottom borough, Jackson township, Jessup township, Lanesboro borough, Lathrop township, Lenox township, Liberty township, Little Meadows borough, Middletown township, Montrose borough, New Milford borough, Oakland borough, Oakland township, Rush township, Silver Lake township, Springville township, Susquehanna Depot borough, Thompson borough, Thompson township, Union Dale borough.

Counties near Susquehanna County

Closest first. Groundwater does not stop at a line on a map, so the next county over is a fair second opinion.

Want the numbers themselves? Download the Pennsylvania dataset as CSV, every county and town, with the sources named.

Sources

  • USGS Water Quality Portal: 1,055 samples in Susquehanna County. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
  • Penn State Agricultural Analytical Services Lab drinking water summaries: summaries for 10 contaminants in Susquehanna County, up to 351 wells each. County summaries of private water samples tested by the Penn State Agricultural Analytical Services Laboratory since 2007, published by the College of Agricultural Sciences. Counts are samples, not distinct wells. Shares are against the standard the lab prints: the EPA maximum contaminant level, or the secondary standard for iron, manganese and chloride. Lead is the first-draw result. Medians printed as 0.00 are stored as null because the lab rounds to two decimals. Retrieved September 16, 2026.
  • USGS national arsenic model (Ayotte 2017): estimated share of 31,518 people on private wells in Susquehanna County above 10 ug/L of arsenic, from geology, well depth and land use. County estimates of domestic well users with arsenic above 10 ug/L from the USGS national logistic regression model (Ayotte, Medalie and Qi, 2017), with private well population from the USGS 2015 county water-use compilation (Dieter and others, 2018). Retrieved September 15, 2026.
  • Pennsylvania Groundwater Information System (PaGWIS) wells: 3,862 well records in Susquehanna County, 2,866 domestic. Water well records from the Pennsylvania Groundwater Information System, Pennsylvania Geological Survey (DCNR). Only aggregates are shown; owner names and addresses are never stored. Retrieved September 16, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.