Well Water Nerd

Well water in Western Connecticut Planning Region, Connecticut

1in10

Testing recommended

tested well samples in Western Connecticut Planning Region exceeded the EPA limit for nitrate (10 mg/L), based on public data from USGS Water Quality Portal and Connecticut DPH and USGS arsenic and uranium survey.

1,534 test results across 11 contaminants from at least 182 wells, 1960 to 2015; chloride has the most at 253. Data refreshed September 3, 2026.

Compiled by Nick at Well Water Nerd from public records. How these pages are built

What individual samples found

Each row summarizes every public sample for that contaminant inside Western Connecticut Planning Region. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.

ContaminantAbove limitSamplesDetectedMedianHighestLimit
Nitrate
1960 to 1993
21999%0.834610 mg/L
EPA limit
Uranium
1988 to 2015
9659%1.576630 ug/L
EPA limit
Arsenic
1977 to 2015
13530%011510 ug/L
EPA limit
Lead
1976 to 1985
4873%060015 ug/L
EPA limit
Fluoride
1962 to 1993
12454%0.10.54 mg/L
EPA limit
Copper
1968 to 1985
3364%00.61.3 mg/L
EPA limit
Radium (226 + 228)
1988
100%005 pCi/L
EPA limit
Chloride
1960 to 2007
no limit253100%131,700250 mg/L
nuisance level
Iron
1960 to 1993
no limit22296%9565,000300 ug/L
nuisance level
Manganese
1960 to 1993
no limit21994%3029,000300 ug/L
health guideline
Sodium
1960 to 1993
no limit175100%8.784820 mg/L
health guideline

Over time

Share of samples above the limit by period. A cell needs ten samples to show; a comparison needs twenty in each period. Later periods sample fewer wells, and often the ones already known to have a problem.

Contaminantbefore 20002000s2010s2020s
Arsenic0%37 samplesn/a8%98 samplesn/a
Uranium6%16 samplesn/a8%80 samplesn/a

Arsenic above the limit in Western Connecticut Planning Region rose from 0% of 37 samples before 2000 to 8% of 98 in the 2010s.

Closer than the county

See the sampled wells near your address

The same records, drawn around one point: which wells within a few miles were sampled and what they found, how deep the wells next to you were drilled, and any leaking tank or cleanup site within a mile.

Check my address

What this means

The contaminants most often above their limit here are nitrate (10% of 219 samples), uranium (7% of 96 samples), and arsenic (6% of 135 samples). A well next door can differ sharply from yours because bedrock fractures, well depth and plumbing all matter, so these rates describe the area, not your tap.

Chloride, Iron, and Manganese are widespread in local groundwater. They are mainly a staining and taste problem, but high manganese also carries a health advisory for infants.

What to test for in Western Connecticut Planning Region

  1. 1
    Nitrate
    10% of 219 local samples were above the limit.
  2. 2
    Uranium
    7% of 96 local samples were above the limit.
  3. 3
    Arsenic
    6% of 135 local samples were above the limit.
  4. 4
    Lead
    4% of 48 local samples were above the limit.
  5. 5
    Coliform bacteria
    Recommended for every private well, every year.
  6. 6
    Chloride
    Detected in 100% of local samples.
  7. 7
    Iron
    Detected in 96% of local samples.
  8. 8
    Volatile organic compounds (VOCs)
    3,598 leaking underground storage tank sites on record locally.
  9. 9
    Metals panel
    10 hazardous waste sites on record locally.

Test your Western Connecticut Planning Region well for nitrate, uranium and arsenic

Certified lab analysis of your own tap water, bottles and prepaid return shipping included. The Essential well panel covers arsenic, uranium, nitrate, lead, copper, manganese, iron, sodium and bacteria; radon and PFAS are add-ons.

Order the Tap Score well water test kit, from $209Already tested? Upload the report

Just want bacteria checked first? Tap Score coliform and E. coli test, $99. Coliform and E. coli are the tests every well needs every year.

Want a quick look before paying for a lab? Home well water test strips on Amazon check hardness, iron, pH and nitrate in minutes. They are a screen, not a result: arsenic, bacteria, uranium and PFAS need a certified lab.

Affiliate links: the merchant pays us a commission and the price is the same for you. It does not change what the data above says. As an Amazon Associate we earn from qualifying purchases.

Where to get a well tested in Connecticut: certified labs, state programs and prices.

Already have results back? Get your lab report read against the Western Connecticut Planning Region numbers, $29. Every line explained, ranked by what matters, with the fix for each.

Wells in Western Connecticut Planning Region

388 domestic wells in Western Connecticut Planning Region are on record with the state since 2001. the typical well is 400 feet deep (one in ten goes past 710 feet).

In a typical Western Connecticut Planning Region well, the median yield is 10 gallons per minute, 15% of wells yield under 3 gallons per minute and usually need a storage tank.

5
2000s
7
2010s
376
2020s

Find your own well's report

The state keeps the driller's report for most wells drilled since 1984. It tells you how deep your well is, where bedrock starts, and how much water it makes, which decides what treatment can work.

  1. Open Connecticut well completion reports and choose Water Well.
  2. The report lists depth, depth to rock, casing, static water level and yield.

Only reports filed online since January 2021 are here; older paper reports are held by the Department of Consumer Protection.

The rock under Western Connecticut Planning Region

Not a principal aquifer

The USGS map places this area outside any principal aquifer, which usually means wells here draw from fractured bedrock or thin local deposits rather than a large regional aquifer. Bedrock wells of that kind are where arsenic, radon and uranium turn up, and yields vary from well to well.

Classification from the USGS Principal Aquifers of the United States (national map, 2003 edition, GIS release 2015), read at the planning region centroid. A single well can sit in a different unit, especially near a boundary.

Official help in Connecticut

Two places to start that are not selling anything: the state program that answers private well questions, and its list of labs certified to run drinking water tests. A certified lab is the difference between a result you can act on and a number.

Contamination sources on record in Western Connecticut Planning Region

CT DEEP contaminated sites and landfills records 3,598 leaking underground storage tank sites, 10 hazardous waste sites, and 74 reported spills and releases in Western Connecticut Planning Region, among 5,085 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.

3,598
leaking underground storage tank sitesGasoline and heating oil that leaked from tanks move through groundwater as benzene, MTBE and other volatile organic compounds.
10
hazardous waste sitesSolvents, degreasers and metals from industrial sites can travel far in fractured bedrock.
74
reported spills and releasesMost spills are fuel; a few are solvents or chemicals that reach the water table.
35
lined landfills and transfer facilities
1,368
other remediation projects

Treatment that fits the local profile

Nitrate

Point-of-use reverse osmosis; Anion exchange; Distillation

Uranium

Point-of-use reverse osmosis; Anion exchange; Whole-house anion exchange

Arsenic

Point-of-use reverse osmosis; Adsorptive media (iron-based) whole-house; Anion exchange

Lead

Point-of-use reverse osmosis; Certified lead-removal carbon filter; Neutralizing filter to raise pH and stop leaching

Iron

Oxidizing filter whole-house; Water softener (low levels); Aeration plus filtration

Systems we would look at first

Some links below are affiliate links. If you buy through one, the merchant pays us a commission at no extra cost to you. It does not change which products we list or what the data says.

For nitrate

Under-sink reverse osmosis system

under-sink or countertop, about $300

Look for NSF/ANSI 58 certification listing the contaminant you need removed.

For nitrate

Aquasana SmartFlow reverse osmosis

under-sink or countertop, about $225

Certified to NSF/ANSI 58 and 53 to reduce arsenic (96%, pentavalent), fluoride (90%), lead (99%), nitrate, nitrite and PFOA/PFOS at the kitchen tap, with a remineralizer.

For uranium

Whole-house arsenic and uranium filter

whole-house, at the point of entry, about $2,500

Adsorptive iron-based media; sized to your well yield.

For lead

Aquasana Claryum 3-Stage under-sink filter

under-sink or countertop, about $175

Certified to NSF/ANSI 53 to reduce 99% of lead and 99.7% of PFOA and PFOS at the tap. Not a fix for arsenic, nitrate or bacteria.

For lead

Acid neutralizing filter

whole-house, at the point of entry, about $1,200

Raises pH so plumbing stops leaching lead and copper.

For iron

Iron and manganese oxidizing filter

whole-house, at the point of entry, about $1,800

Air-injection or greensand media; fixes staining at the source.

Free, no obligation

Get on the list for a free in-home water test in Western Connecticut Planning Region

No water treatment company serves Western Connecticut Planning Region through Well Water Nerd yet. We are signing licensed companies on county by county: they test at your tap for free, walk you through the numbers, and quote treatment only if something needs fixing. Leave your details and you are first in line. Nothing is shared until a company joins for Western Connecticut Planning Region, and you get an email naming it first.

What are you worried about?

The test is free and there is no obligation. No company is named yet; your details stay with us until one joins for your area, and we log the time and address of this request.

Common questions

How deep are wells in Western Connecticut Planning Region?

The typical domestic well in Western Connecticut Planning Region is 400 feet deep, based on 388 wells reported to the state since 2001. One in ten is deeper than 710 feet.

Is there arsenic in well water in Western Connecticut Planning Region?

Arsenic was detected in 30% of 135 public well samples in Western Connecticut Planning Region, and 6% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.

How often should I test a private well in Western Connecticut Planning Region?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Towns in Western Connecticut Planning Region

16 towns have fewer than 30 public samples and are included in the Western Connecticut Planning Region totals above rather than shown separately: Bethel, Bridgewater, Brookfield, Danbury, Darien, Greenwich, New Canaan, New Fairfield, New Milford, Norwalk, Redding, Ridgefield, Sherman, Stamford, Weston, Westport.

Planning regions near Western Connecticut Planning Region

Closest first. Groundwater does not stop at a line on a map, so the next planning region over is a fair second opinion.

Want the numbers themselves? Download the Connecticut dataset as CSV, every county and town, with the sources named.

Sources

  • USGS Water Quality Portal: 1,356 samples in Western Connecticut Planning Region. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
  • Connecticut DPH and USGS arsenic and uranium survey: 178 samples in Western Connecticut Planning Region. Arsenic and uranium in 674 private bedrock wells sampled by the Connecticut Department of Public Health with the U.S. Geological Survey, 2013 to 2015. Retrieved .
  • Connecticut well completion reports: 1,611 well records in Western Connecticut Planning Region, 388 domestic. Well completion reports filed online with the Connecticut Department of Consumer Protection since January 2021. Only aggregates are shown; owner names and addresses are never stored. Retrieved September 16, 2026.
  • CT DEEP contaminated sites and landfills: 5,085 regulated sites located in Western Connecticut Planning Region. Contaminated or potentially contaminated sites and solid waste landfills from the Connecticut Department of Energy and Environmental Protection. Retrieved September 16, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.