Well Water Nerd

Well water in South Central Connecticut Planning Region, Connecticut

1in5

Testing strongly recommended

tested well samples in South Central Connecticut Planning Region exceeded the EPA limit for nitrate (10 mg/L), based on public data from USGS Water Quality Portal and Connecticut DPH and USGS arsenic and uranium survey.

1,189 test results across 13 contaminants from at least 141 wells, 1962 to 2017; chloride has the most at 416. Data refreshed September 3, 2026.

Compiled by Nick at Well Water Nerd from public records. How these pages are built

What individual samples found

Each row summarizes every public sample for that contaminant inside South Central Connecticut Planning Region. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.

ContaminantAbove limitSamplesDetectedMedianHighestLimit
Nitrate
1962 to 2017
21996%4.296610 mg/L
EPA limit
Arsenic
1971 to 2017
4838%02010 ug/L
EPA limit
Fluoride
1966 to 2017
6572%0.114 mg/L
EPA limit
Uranium
1988 to 2017
4159%0.591430 ug/L
EPA limit
Lead
1971 to 2017
1191%00.29115 ug/L
EPA limit
Chloride
1962 to 2017
no limit416100%548,300250 mg/L
nuisance level
Manganese
1962 to 2017
no limit15299%04,700300 ug/L
health guideline
Iron
1962 to 2017
no limit15198%64.94,300300 ug/L
nuisance level
Sodium
1966 to 2017
no limit66100%1413020 mg/L
health guideline

Sampled fewer than 10 times, too few to summarize: Radium (226 + 228) (9), Copper (6), E. coli (2), Radon (3).

Over time

Share of samples above the limit by period. A cell needs ten samples to show; a comparison needs twenty in each period. Later periods sample fewer wells, and often the ones already known to have a problem.

Contaminantbefore 20002000s2010s2020s
Arsenic7%15 samplesn/a3%32 samplesn/a

Closer than the county

See the sampled wells near your address

The same records, drawn around one point: which wells within a few miles were sampled and what they found, how deep the wells next to you were drilled, and any leaking tank or cleanup site within a mile.

Check my address

What this means

The contaminants most often above their limit here are nitrate (20% of 219 samples) and arsenic (4% of 48 samples). A well next door can differ sharply from yours because bedrock fractures, well depth and plumbing all matter, so these rates describe the area, not your tap.

Chloride, Manganese, and Iron are widespread in local groundwater. They are mainly a staining and taste problem, but high manganese also carries a health advisory for infants.

What to test for in South Central Connecticut Planning Region

  1. 1
    Nitrate
    20% of 219 local samples were above the limit.
  2. 2
    Arsenic
    4% of 48 local samples were above the limit.
  3. 3
    Coliform bacteria
    Recommended for every private well, every year.
  4. 4
    Radon
    Median local reading is 1,600 pCi/L.
  5. 5
    Copper
    Detected in 100% of local samples.
  6. 6
    Chloride
    Detected in 100% of local samples.
  7. 7
    Manganese
    Detected in 99% of local samples.
  8. 8
    Volatile organic compounds (VOCs)
    1,167 leaking underground storage tank sites on record locally.
  9. 9
    Metals panel
    18 hazardous waste sites on record locally.

Test your South Central Connecticut Planning Region well for nitrate, arsenic and coliform bacteria

Certified lab analysis of your own tap water, bottles and prepaid return shipping included. The Essential well panel covers arsenic, uranium, nitrate, lead, copper, manganese, iron, sodium and bacteria; radon and PFAS are add-ons.

Order the Tap Score well water test kit, from $209Already tested? Upload the report

Just want bacteria checked first? Tap Score coliform and E. coli test, $99. Coliform and E. coli are the tests every well needs every year.

Want a quick look before paying for a lab? Home well water test strips on Amazon check hardness, iron, pH and nitrate in minutes. They are a screen, not a result: arsenic, bacteria, uranium and PFAS need a certified lab.

Affiliate links: the merchant pays us a commission and the price is the same for you. It does not change what the data above says. As an Amazon Associate we earn from qualifying purchases.

Where to get a well tested in Connecticut: certified labs, state programs and prices.

Already have results back? Get your lab report read against the South Central Connecticut Planning Region numbers, $29. Every line explained, ranked by what matters, with the fix for each.

Wells in South Central Connecticut Planning Region

178 domestic wells in South Central Connecticut Planning Region are on record with the state since 2017. the typical well is 348 feet deep (one in ten goes past 622 feet).

In a typical South Central Connecticut Planning Region well, the median yield is 8 gallons per minute, 23% of wells yield under 3 gallons per minute and usually need a storage tank.

176
2020s

Find your own well's report

The state keeps the driller's report for most wells drilled since 1984. It tells you how deep your well is, where bedrock starts, and how much water it makes, which decides what treatment can work.

  1. Open Connecticut well completion reports and choose Water Well.
  2. The report lists depth, depth to rock, casing, static water level and yield.

Only reports filed online since January 2021 are here; older paper reports are held by the Department of Consumer Protection.

The rock under South Central Connecticut Planning Region

Early Mesozoic basin aquifers

Sandstone. Sandstone wells draw from pore space in the rock and tend to be dependable. Iron, manganese and hardness are common, and some sandstones carry arsenic or radium, so a first test should include both.

Classification from the USGS Principal Aquifers of the United States (national map, 2003 edition, GIS release 2015), read at the planning region centroid. A single well can sit in a different unit, especially near a boundary.

Official help in Connecticut

Two places to start that are not selling anything: the state program that answers private well questions, and its list of labs certified to run drinking water tests. A certified lab is the difference between a result you can act on and a number.

Contamination sources on record in South Central Connecticut Planning Region

CT DEEP contaminated sites and landfills records 1,167 leaking underground storage tank sites, 18 hazardous waste sites, and 62 reported spills and releases in South Central Connecticut Planning Region, among 2,675 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.

1,167
leaking underground storage tank sitesGasoline and heating oil that leaked from tanks move through groundwater as benzene, MTBE and other volatile organic compounds.
18
hazardous waste sitesSolvents, degreasers and metals from industrial sites can travel far in fractured bedrock.
62
reported spills and releasesMost spills are fuel; a few are solvents or chemicals that reach the water table.
29
lined landfills and transfer facilities
1,399
other remediation projects

Treatment that fits the local profile

Nitrate

Point-of-use reverse osmosis; Anion exchange; Distillation

Arsenic

Point-of-use reverse osmosis; Adsorptive media (iron-based) whole-house; Anion exchange

Manganese

Oxidizing filter (greensand, birm) whole-house; Water softener (low levels); Point-of-use reverse osmosis

Iron

Oxidizing filter whole-house; Water softener (low levels); Aeration plus filtration

Systems we would look at first

Some links below are affiliate links. If you buy through one, the merchant pays us a commission at no extra cost to you. It does not change which products we list or what the data says.

For nitrate

Under-sink reverse osmosis system

under-sink or countertop, about $300

Look for NSF/ANSI 58 certification listing the contaminant you need removed.

For nitrate

Aquasana SmartFlow reverse osmosis

under-sink or countertop, about $225

Certified to NSF/ANSI 58 and 53 to reduce arsenic (96%, pentavalent), fluoride (90%), lead (99%), nitrate, nitrite and PFOA/PFOS at the kitchen tap, with a remineralizer.

For arsenic

Whole-house arsenic and uranium filter

whole-house, at the point of entry, about $2,500

Adsorptive iron-based media; sized to your well yield.

For manganese

Iron and manganese oxidizing filter

whole-house, at the point of entry, about $1,800

Air-injection or greensand media; fixes staining at the source.

Free, no obligation

Get on the list for a free in-home water test in South Central Connecticut Planning Region

No water treatment company serves South Central Connecticut Planning Region through Well Water Nerd yet. We are signing licensed companies on county by county: they test at your tap for free, walk you through the numbers, and quote treatment only if something needs fixing. Leave your details and you are first in line. Nothing is shared until a company joins for South Central Connecticut Planning Region, and you get an email naming it first.

What are you worried about?

The test is free and there is no obligation. No company is named yet; your details stay with us until one joins for your area, and we log the time and address of this request.

Common questions

How deep are wells in South Central Connecticut Planning Region?

The typical domestic well in South Central Connecticut Planning Region is 348 feet deep, based on 178 wells reported to the state since 2017. One in ten is deeper than 622 feet.

Is there arsenic in well water in South Central Connecticut Planning Region?

Arsenic was detected in 38% of 48 public well samples in South Central Connecticut Planning Region, and 4% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.

How often should I test a private well in South Central Connecticut Planning Region?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Towns in South Central Connecticut Planning Region

13 towns have fewer than 30 public samples and are included in the South Central Connecticut Planning Region totals above rather than shown separately: Bethany, Branford, East Haven, Guilford, Madison, Meriden, Milford, North Branford, North Haven, Orange, Wallingford, West Haven, Woodbridge.

Planning regions near South Central Connecticut Planning Region

Closest first. Groundwater does not stop at a line on a map, so the next planning region over is a fair second opinion.

Want the numbers themselves? Download the Connecticut dataset as CSV, every county and town, with the sources named.

Sources

  • USGS Water Quality Portal: 1,131 samples in South Central Connecticut Planning Region. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
  • Connecticut DPH and USGS arsenic and uranium survey: 58 samples in South Central Connecticut Planning Region. Arsenic and uranium in 674 private bedrock wells sampled by the Connecticut Department of Public Health with the U.S. Geological Survey, 2013 to 2015. Retrieved .
  • Connecticut well completion reports: 719 well records in South Central Connecticut Planning Region, 178 domestic. Well completion reports filed online with the Connecticut Department of Consumer Protection since January 2021. Only aggregates are shown; owner names and addresses are never stored. Retrieved September 16, 2026.
  • CT DEEP contaminated sites and landfills: 2,675 regulated sites located in South Central Connecticut Planning Region. Contaminated or potentially contaminated sites and solid waste landfills from the Connecticut Department of Energy and Environmental Protection. Retrieved September 16, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.