In Dellona, 6% of 35 private wells tested between 2007 and 2025 had total coliform above the Wisconsin limit (any detection), according to the UWSP Well Water Quality Viewer.

187 private wells tested 2007 to 2022 in state summaries. Data refreshed September 9, 2026.

What homeowner tests found

Wisconsin Well Water Quality Viewer samples: private wells tested and reported to the state, 2007 to 2022. Shares are against the level the state applies to each contaminant, named in the last column; several are stricter than EPA.

ContaminantWells testedAbove state levelMedian95th pctHighestState level
Copper2623%0.1499.6515.91.3 mg/L
Sodium2317%2.727.474.320 mg/L
Total coliform356%
Nitrate1875%2.6910.12410 mg/L
Manganese264%0128540300 ug/L
Lead264%092815 ug/L
Chloride452%9.3138283250 mg/L
Arsenic500%000.06510 ug/L
Iron240%681131300 ug/L
E. coli20%

Get the free Dellona well report

One email with the numbers above, what they mean for a home in Dellona, exactly which tests to order, and what treatment fits the local profile. No spam, unsubscribe in one click.

What this means

Among homeowners in Dellona who sent a sample to the state lab, the health-based limits most often exceeded were copper (23% of 26 wells), total coliform (6% of 35 wells), and nitrate (5% of 187 wells). These are ordinary wells tested by their owners, so the shares are the best available picture of a typical well here, with one caveat: people test more often when they suspect a problem.

Sodium exceeds the state's advisory level in a sizable share of wells; this is mostly a taste, staining or diet issue rather than a toxicity one.

What to test for in Dellona

  • Copper23% of 26 local wells tested were above the Wisconsin enforcement standard.
  • Sodium17% of 23 local wells tested were above the EPA advisory level.
  • Total coliform6% of 35 local wells tested were above the Wisconsin limit (any detection).
  • Nitrate5% of 187 local wells tested were above the Wisconsin enforcement standard.
  • Manganese4% of 26 local wells tested were above the Wisconsin enforcement standard.
  • Lead4% of 26 local wells tested were above the Wisconsin enforcement standard.
  • Chloride2% of 45 local wells tested were above the Wisconsin nuisance level.
  • Coliform bacteriaRecommended for every private well, every year.

Treatment that fits the local profile

Copper
Neutralizing filter to raise pH; Point-of-use reverse osmosis
Total coliform
Inspect and repair the well cap and casing, then shock chlorinate and retest; UV disinfection whole-house; Chlorination system
Nitrate
Point-of-use reverse osmosis; Anion exchange; Distillation
Sodium
Point-of-use reverse osmosis; Distillation

Get your Dellona water tested at home

A licensed local water treatment company tests your tap water in your home, walks you through the numbers, and quotes treatment only if something needs fixing. Free, about 30 minutes, no obligation. Tell us what you need and we match you with a company that serves Dellona.

What are you worried about?

The test is free and there is no obligation. Your details go only to the company named above, and we log the time and address of this request.

Common questions

How often should I test a private well in Dellona?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Sources

  • Wisconsin Well Water Quality Viewer samples: summaries for 10 contaminants in Dellona, up to 187 wells each. Private well samples compiled by the UWSP Center for Watershed Science and Education from the DNR Groundwater Retrieval Network, DATCP surveys, the UWSP Water and Environmental Analysis Lab and county health programs, published in the Wisconsin Well Water Quality Viewer with Wisconsin DHS. Samples are located to the town, village or city they fall in; one result per well and parameter (the latest) so repeat samples do not double count; wells without a state well number are keyed by location. Shares are against Wisconsin NR 140 enforcement standards (arsenic 10 ug/L, nitrate 10 mg/L as N, manganese 300 ug/L, lead 15 ug/L, copper 1.3 mg/L) and the iron and chloride secondary levels. Many samples were submitted by homeowners with a reason to test, so shares can run above a random survey. Retrieved September 9, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.