Well Water Nerd

Well water in Sharon, Wisconsin

1in5

Testing strongly recommended

private wells tested between 1988 and 2025 in Sharon had nitrate above the Wisconsin enforcement standard (10 mg/L), according to the UWSP Well Water Quality Viewer.

269 private wells tested 1988 to 2025 in state summaries; 654 test results across 12 contaminants from at least 27 wells, 1953 to 2019; nitrate has the most at 155. Data refreshed September 9, 2026.

Compiled by Nick at Well Water Nerd from public records. How these pages are built

What homeowner tests found

Wisconsin Well Water Quality Viewer samples: private wells tested and reported to the state, 1988 to 2025. Shares are against the level the state applies to each contaminant, named in the last column; several are stricter than EPA.

ContaminantAbove state levelWells testedMedian95th pctHighestState level
Nitrate2693.7618.727.910 mg/L
Iron1509,9049,904300 ug/L
Total coliform91
Manganese170812812300 ug/L
Chloride10310.263.7167250 mg/L
Arsenic25067.210 ug/L
Copper170.0190.7450.7451.3 mg/L
Lead170111115 ug/L
Sodium1508.138.1320 mg/L
E. coli5

What individual samples found

Each row summarizes every public sample for that contaminant inside Sharon. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.

ContaminantAbove limitSamplesDetectedMedianHighestLimit
Nitrate
1953 to 2019
155100%5.4661.610 mg/L
EPA limit
Fluoride
1953 to 2019
7097%0.20.314 mg/L
EPA limit
Uranium
2014 to 2019
36100%2.268.1630 ug/L
EPA limit
Lead
2014 to 2019
3633%00.9815 ug/L
EPA limit
Arsenic
2014 to 2019
36100%0.3050.5110 ug/L
EPA limit
Copper
2014 to 2019
3563%0.0040.7551.3 mg/L
EPA limit
Manganese
1953 to 2019
no limit7037%083.9300 ug/L
health guideline
Iron
1953 to 2019
no limit7024%0143300 ug/L
nuisance level
Chloride
1953 to 2019
no limit70100%7.220.3250 mg/L
nuisance level
Sodium
1953 to 2019
no limit70100%2.696.8520 mg/L
health guideline

Sampled fewer than 10 times, too few to summarize: Radium (226 + 228) (4), Radon (2).

Over time

Share of samples above the limit by period. A cell needs ten samples to show; a comparison needs twenty in each period. Later periods sample fewer wells, and often the ones already known to have a problem.

Contaminantbefore 20002000s2010s2020s
Nitraten/a21%42 samples25%112 samplesn/a
Fluoriden/a0%17 samples0%52 samplesn/a

Nitrate has held within a few points between the two most recent periods with enough samples.

Closer than the town

See the sampled wells near your address

The same records, drawn around one point: which wells within a few miles were sampled and what they found, how deep the wells next to you were drilled, and any leaking tank or cleanup site within a mile.

Check my address

What this means

Among homeowners in Sharon who sent a sample to the state lab, the health-based limits most often exceeded were nitrate (19% of 269 wells) and total coliform (7% of 91 wells). These are ordinary wells tested by their owners, so the shares are the best available picture of a typical well here, with one caveat: people test more often when they suspect a problem.

Iron exceeds the state's advisory level in a sizable share of wells; this is mostly a taste, staining or diet issue rather than a toxicity one.

What to test for in Sharon

  1. 1
    Nitrate
    24% of 155 local samples were above the limit.
  2. 2
    Total coliform
    7% of 91 local wells tested were above the Wisconsin limit (any detection).
  3. 3
    Coliform bacteria
    Recommended for every private well, every year.
  4. 4
    Radon
    Median local reading is 458 pCi/L.
  5. 5
    Iron
    13% of 15 local wells tested were above the Wisconsin nuisance level.
  6. 6
    Manganese
    6% of 17 local wells tested were above the Wisconsin enforcement standard.
  7. 7
    Chloride
    Detected in 100% of local samples.
  8. 8
    Fluoride
    Detected in 97% of local samples.
  9. 9
    Volatile organic compounds (VOCs)
    4 leaking underground storage tank sites on record locally.

Test your Sharon well for nitrate, total coliform and coliform bacteria

Certified lab analysis of your own tap water, bottles and prepaid return shipping included. The Essential well panel covers arsenic, uranium, nitrate, lead, copper, manganese, iron, sodium and bacteria; radon and PFAS are add-ons.

Order the Tap Score well water test kit, from $209Already tested? Upload the report

Just want bacteria checked first? Tap Score coliform and E. coli test, $99. Coliform and E. coli are the tests every well needs every year.

Want a quick look before paying for a lab? Home well water test strips on Amazon check hardness, iron, pH and nitrate in minutes. They are a screen, not a result: arsenic, bacteria, uranium and PFAS need a certified lab.

Affiliate links: the merchant pays us a commission and the price is the same for you. It does not change what the data above says. As an Amazon Associate we earn from qualifying purchases.

Where to get a well tested in Wisconsin: certified labs, state programs and prices.

Already have results back? Get your lab report read against the Sharon numbers, $29. Every line explained, ranked by what matters, with the fix for each.

The rock under Sharon

Cambrian-Ordovician aquifer system

Sandstone. Sandstone wells draw from pore space in the rock and tend to be dependable. Iron, manganese and hardness are common, and some sandstones carry arsenic or radium, so a first test should include both.

Classification from the USGS Principal Aquifers of the United States (national map, 2003 edition, GIS release 2015), read at the town centroid. A single well can sit in a different unit, especially near a boundary.

Official help in Wisconsin

Two places to start that are not selling anything: the state program that answers private well questions, and its list of labs certified to run drinking water tests. A certified lab is the difference between a result you can act on and a number.

Contamination sources on record in Sharon

Wisconsin DNR records 4 leaking underground storage tank sites in Sharon, among 18 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.

4
leaking underground storage tank sitesGasoline and heating oil that leaked from tanks move through groundwater as benzene, MTBE and other volatile organic compounds.
3
lined landfills and transfer facilities
11
other remediation projects

Treatment that fits the local profile

Nitrate

Point-of-use reverse osmosis; Anion exchange; Distillation

Total coliform

Inspect and repair the well cap and casing, then shock chlorinate and retest; UV disinfection whole-house; Chlorination system

Iron

Oxidizing filter whole-house; Water softener (low levels); Aeration plus filtration

Manganese

Oxidizing filter (greensand, birm) whole-house; Water softener (low levels); Point-of-use reverse osmosis

Systems we would look at first

Some links below are affiliate links. If you buy through one, the merchant pays us a commission at no extra cost to you. It does not change which products we list or what the data says.

For nitrate

Under-sink reverse osmosis system

under-sink or countertop, about $300

Look for NSF/ANSI 58 certification listing the contaminant you need removed.

For nitrate

Aquasana SmartFlow reverse osmosis

under-sink or countertop, about $225

Certified to NSF/ANSI 58 and 53 to reduce arsenic (96%, pentavalent), fluoride (90%), lead (99%), nitrate, nitrite and PFOA/PFOS at the kitchen tap, with a remineralizer.

For total coliform

Aquasana Rhino Well Water with UV

whole-house, at the point of entry, about $2,871

Whole-house system built for wells: sediment pre-filter, KDF and carbon, and a UV lamp rated to kill 99.99% of bacteria and viruses. It does not remove arsenic, nitrate, uranium or radon.

For iron

Iron and manganese oxidizing filter

whole-house, at the point of entry, about $1,800

Air-injection or greensand media; fixes staining at the source.

Free, no obligation

Get on the list for a free in-home water test in Sharon

No water treatment company serves Sharon through Well Water Nerd yet. We are signing licensed companies on county by county: they test at your tap for free, walk you through the numbers, and quote treatment only if something needs fixing. Leave your details and you are first in line. Nothing is shared until a company joins for Sharon, and you get an email naming it first.

What are you worried about?

The test is free and there is no obligation. No company is named yet; your details stay with us until one joins for your area, and we log the time and address of this request.

Common questions

Is there arsenic in well water in Sharon?

Arsenic was detected in 100% of 36 public well samples in Sharon, and 0% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.

How often should I test a private well in Sharon?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Towns near Sharon

Closest first. Groundwater does not stop at a line on a map, so the next town over is a fair second opinion.

Want the numbers themselves? Download the Wisconsin dataset as CSV, every county and town, with the sources named.

Sources

  • USGS Water Quality Portal: 654 samples in Sharon. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
  • Wisconsin Well Water Quality Viewer samples: summaries for 10 contaminants in Sharon, up to 269 wells each. Private well samples compiled by the UWSP Center for Watershed Science and Education from the DNR Groundwater Retrieval Network, DATCP surveys, the UWSP Water and Environmental Analysis Lab and county health programs, published in the Wisconsin Well Water Quality Viewer with Wisconsin DHS. Samples are located to the town, village or city they fall in; one result per well and parameter (the latest) so repeat samples do not double count; wells without a state well number are keyed by location. Shares are against Wisconsin NR 140 enforcement standards (arsenic 10 ug/L, nitrate 10 mg/L as N, manganese 300 ug/L, lead 15 ug/L, copper 1.3 mg/L) and the iron and chloride secondary levels. Many samples were submitted by homeowners with a reason to test, so shares can run above a random survey. Retrieved September 9, 2026.
  • Wisconsin DNR regulated sites: 18 regulated sites located in Sharon. Open and closed remediation activities (BRRTS, including leaking underground storage tanks and spills) and landfill and waste sites from the Wisconsin Department of Natural Resources. Retrieved September 9, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.