Well Water Nerd

Well water in Wiota, Wisconsin

In Wiota, 10% of 82 private wells tested between 1991 and 2025 had nitrate above the Wisconsin enforcement standard (10 mg/L), according to the UWSP Well Water Quality Viewer.

82 private wells tested 2007 to 2017 in state summaries; 1 individual samples from 1 wells, 1970. Data refreshed September 9, 2026.

What homeowner tests found

Wisconsin Well Water Quality Viewer samples: private wells tested and reported to the state, 2007 to 2017. Shares are against the level the state applies to each contaminant, named in the last column; several are stricter than EPA.

ContaminantWells testedAbove state levelMedian95th pctHighestState level
Total coliform450%
Nitrate8210%1.011416.610 mg/L
Arsenic100%07710 ug/L
Chloride40%6.917.917.9250 mg/L
Iron30%11168168300 ug/L
Sodium30%5.612.312.320 mg/L
Manganese30%055300 ug/L
Lead30%11115 ug/L
Copper30%0.1380.1950.1951.3 mg/L
E. coli20%

Get the free Wiota well report

One email with the numbers above, what they mean for a home in Wiota, exactly which tests to order, and what treatment fits the local profile. No spam, unsubscribe in one click.

What this means

Among homeowners in Wiota who sent a sample to the state lab, the health-based limits most often exceeded were nitrate (10% of 82 wells). These are ordinary wells tested by their owners, so the shares are the best available picture of a typical well here, with one caveat: people test more often when they suspect a problem.

What to test for in Wiota

  • Volatile organic compounds (VOCs)1 leaking underground storage tank site on record locally.
  • Nitrate10% of 82 local wells tested were above the Wisconsin enforcement standard.
  • Coliform bacteriaRecommended for every private well, every year.
  • ChlorideDetected in 100% of local samples.

Contamination sources on record in Wiota

Wisconsin DNR records 1 leaking underground storage tank site in Wiota, among 5 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.

1
leaking underground storage tank siteGasoline and heating oil that leaked from tanks move through groundwater as benzene, MTBE and other volatile organic compounds.
2
lined landfills and transfer facilities
2
other remediation projects

Treatment that fits the local profile

Nitrate
Point-of-use reverse osmosis; Anion exchange; Distillation
Chloride
Point-of-use reverse osmosis; Distillation

Get your Wiota water tested at home

A licensed local water treatment company tests your tap water in your home, walks you through the numbers, and quotes treatment only if something needs fixing. Free, about 30 minutes, no obligation. Tell us what you need and we match you with a company that serves Wiota.

What are you worried about?

The test is free and there is no obligation. Your details go only to the company named above, and we log the time and address of this request.

Common questions

How often should I test a private well in Wiota?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Sources

  • USGS Water Quality Portal: 1 samples in Wiota. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
  • Wisconsin Well Water Quality Viewer samples: summaries for 10 contaminants in Wiota, up to 82 wells each. Private well samples compiled by the UWSP Center for Watershed Science and Education from the DNR Groundwater Retrieval Network, DATCP surveys, the UWSP Water and Environmental Analysis Lab and county health programs, published in the Wisconsin Well Water Quality Viewer with Wisconsin DHS. Samples are located to the town, village or city they fall in; one result per well and parameter (the latest) so repeat samples do not double count; wells without a state well number are keyed by location. Shares are against Wisconsin NR 140 enforcement standards (arsenic 10 ug/L, nitrate 10 mg/L as N, manganese 300 ug/L, lead 15 ug/L, copper 1.3 mg/L) and the iron and chloride secondary levels. Many samples were submitted by homeowners with a reason to test, so shares can run above a random survey. Retrieved September 9, 2026.
  • Wisconsin DNR regulated sites: 5 regulated sites located in Wiota. Open and closed remediation activities (BRRTS, including leaking underground storage tanks and spills) and landfill and waste sites from the Wisconsin Department of Natural Resources. Retrieved September 9, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.