Well Water Nerd

Well water in Wascott, Wisconsin

In Wascott, none of 135 private wells tested between 1994 and 2025 had nitrate above the Wisconsin enforcement standard (10 mg/L), according to the UWSP Well Water Quality Viewer.

135 private wells tested 2018 to 2024 in state summaries; 18 individual samples from 15 wells, 1973 to 1986. Data refreshed September 9, 2026.

What homeowner tests found

Wisconsin Well Water Quality Viewer samples: private wells tested and reported to the state, 2018 to 2024. Shares are against the level the state applies to each contaminant, named in the last column; several are stricter than EPA.

ContaminantWells testedAbove state levelMedian95th pctHighestState level
Iron1010%11375375300 ug/L
Total coliform166%
Nitrate1350%01.44.9110 mg/L
Arsenic240%03.74.410 ug/L
Chloride160%0.81414250 mg/L
Copper130%0.0170.670.671.3 mg/L
Lead130%00015 ug/L
Manganese130%164444300 ug/L
Sodium90%1.873.013.0120 mg/L
E. coli10%

What individual samples found

Each row summarizes every public sample for that contaminant inside Wascott. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.

ContaminantSamplesDetectedAbove limitMedianHighestLimit
Copper
1982 to 1986
180%0%001.3 mg/L
EPA limit
Lead
1981 to 1986
147%0%0015 ug/L
EPA limit

Sampled fewer than 10 times, too few to summarize: Nitrate (5), Fluoride (4), Iron (9), Sodium (8), Chloride (7), Manganese (5).

Get the free Wascott well report

One email with the numbers above, what they mean for a home in Wascott, exactly which tests to order, and what treatment fits the local profile. No spam, unsubscribe in one click.

What this means

Among homeowners in Wascott who sent a sample to the state lab, the health-based limits most often exceeded were total coliform (6% of 16 wells). These are ordinary wells tested by their owners, so the shares are the best available picture of a typical well here, with one caveat: people test more often when they suspect a problem.

Iron exceeds the state's advisory level in a sizable share of wells; this is mostly a taste, staining or diet issue rather than a toxicity one.

What to test for in Wascott

  • Iron10% of 10 local wells tested were above the Wisconsin nuisance level.
  • Total coliform6% of 16 local wells tested were above the Wisconsin limit (any detection).
  • Coliform bacteriaRecommended for every private well, every year.
  • ChlorideDetected in 100% of local samples.
  • NitrateRecommended for every private well, especially near farms or septic systems.
  • ManganeseDetected in 60% of local samples.

Contamination sources on record in Wascott

Wisconsin DNR records 10 regulated sites in Wascott, among 10 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.

6
lined landfills and transfer facilities
4
other remediation projects

Treatment that fits the local profile

Total coliform
Inspect and repair the well cap and casing, then shock chlorinate and retest; UV disinfection whole-house; Chlorination system
Iron
Oxidizing filter whole-house; Water softener (low levels); Aeration plus filtration
Chloride
Point-of-use reverse osmosis; Distillation
Manganese
Oxidizing filter (greensand, birm) whole-house; Water softener (low levels); Point-of-use reverse osmosis

Get your Wascott water tested at home

A licensed local water treatment company tests your tap water in your home, walks you through the numbers, and quotes treatment only if something needs fixing. Free, about 30 minutes, no obligation. Tell us what you need and we match you with a company that serves Wascott.

What are you worried about?

The test is free and there is no obligation. Your details go only to the company named above, and we log the time and address of this request.

Common questions

How often should I test a private well in Wascott?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Sources

  • USGS Water Quality Portal: 70 samples in Wascott. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
  • Wisconsin Well Water Quality Viewer samples: summaries for 10 contaminants in Wascott, up to 135 wells each. Private well samples compiled by the UWSP Center for Watershed Science and Education from the DNR Groundwater Retrieval Network, DATCP surveys, the UWSP Water and Environmental Analysis Lab and county health programs, published in the Wisconsin Well Water Quality Viewer with Wisconsin DHS. Samples are located to the town, village or city they fall in; one result per well and parameter (the latest) so repeat samples do not double count; wells without a state well number are keyed by location. Shares are against Wisconsin NR 140 enforcement standards (arsenic 10 ug/L, nitrate 10 mg/L as N, manganese 300 ug/L, lead 15 ug/L, copper 1.3 mg/L) and the iron and chloride secondary levels. Many samples were submitted by homeowners with a reason to test, so shares can run above a random survey. Retrieved September 9, 2026.
  • Wisconsin DNR regulated sites: 10 regulated sites located in Wascott. Open and closed remediation activities (BRRTS, including leaking underground storage tanks and spills) and landfill and waste sites from the Wisconsin Department of Natural Resources. Retrieved September 9, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.