In Armstrong County, 3% of 32 tested well samples exceeded the EPA limit for radium (226 + 228) (5 pCi/L), based on public data from Texas Water Development Board Groundwater Database and USGS Water Quality Portal.

157 individual samples from 30 wells, 1981 to 2024. Data refreshed September 9, 2026.

TWDB samples an ambient monitoring network of wells on a rotation, so these describe aquifers, not a survey of homeowners' tests.

What individual samples found

Each row summarizes every public sample for that contaminant inside Armstrong County. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.

ContaminantSamplesDetectedAbove limitMedianHighestLimit
Gross alpha
1990 to 2024
2186%10%5.0617.415 pCi/L
EPA limit
Radium (226 + 228)
1990 to 2016
3222%3%065 pCi/L
EPA limit
Fluoride
1981 to 2024
15799%1%1.8164 mg/L
EPA limit
Arsenic
1990 to 2024
3884%0%3.968.210 ug/L
EPA limit
Nitrate
1990 to 2024
38100%0%1.665.4210 mg/L
EPA limit
Copper
1990 to 2024
3658%0%0.0010.0321.3 mg/L
EPA limit
Lead
1990 to 2024
363%0%01.615 ug/L
EPA limit
Uranium
1999 to 2024
17100%0%7.1812.730 ug/L
EPA limit
Chloride
1981 to 2024
157100%no limit19109250 mg/L
nuisance level
Sodium
1981 to 2024
48100%no limit30.199.920 mg/L
health guideline
Manganese
1990 to 2024
3837%no limit013.5300 ug/L
health guideline
Iron
1990 to 2024
3829%no limit0846300 ug/L
nuisance level

Sampled fewer than 10 times, too few to summarize: Radon (1).

Get the free Armstrong County well report

One email with the numbers above, what they mean for a home in Armstrong County, exactly which tests to order, and what treatment fits the local profile. No spam, unsubscribe in one click.

What this means

The contaminants most often above their limit here are gross alpha (10% of 21 samples), radium (226 + 228) (3% of 32 samples), and fluoride (1% of 157 samples). A well next door can differ sharply from yours because bedrock fractures, well depth and plumbing all matter, so these rates describe the area, not your tap.

Chloride is widespread in local groundwater. It is mainly a staining and taste problem, but high manganese also carries a health advisory for infants.

What to test for in Armstrong County

  • Volatile organic compounds (VOCs)2 leaking underground storage tank sites on record locally.
  • Gross alpha10% of 21 local samples were above the limit.
  • Radium (226 + 228)3% of 32 local samples were above the limit.
  • Fluoride1% of 157 local samples were above the limit.
  • Coliform bacteriaRecommended for every private well, every year.
  • RadonMedian local reading is 220 pCi/L.
  • ChlorideDetected in 100% of local samples.
  • NitrateRecommended for every private well, especially near farms or septic systems.

Contamination sources on record in Armstrong County

TCEQ records 2 leaking underground storage tank sites in Armstrong County, among 4 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.

2
leaking underground storage tank sitesGasoline and heating oil that leaked from tanks move through groundwater as benzene, MTBE and other volatile organic compounds.
2
lined landfills and transfer facilities

Treatment that fits the local profile

Gross alpha
Point-of-use reverse osmosis; Water softener (cation exchange) for radium; Anion exchange for uranium
Radium (226 + 228)
Water softener (cation exchange); Point-of-use reverse osmosis
Fluoride
Point-of-use reverse osmosis; Activated alumina; Distillation
Copper
Neutralizing filter to raise pH; Point-of-use reverse osmosis
Chloride
Point-of-use reverse osmosis; Distillation

Get your Armstrong County water tested at home

A licensed local water treatment company tests your tap water in your home, walks you through the numbers, and quotes treatment only if something needs fixing. Free, about 30 minutes, no obligation. Tell us what you need and we match you with a company that serves Armstrong County.

What are you worried about?

The test is free and there is no obligation. Your details go only to the company named above, and we log the time and address of this request.

Common questions

Is there arsenic in well water in Armstrong County?

Arsenic was detected in 84% of 38 public well samples in Armstrong County, and 0% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.

How high is radon in well water in Armstrong County?

The median radon level across 1 public samples in Armstrong County was 220 pCi/L, with a high of 220 pCi/L. New Hampshire recommends treatment above 2,000 pCi/L.

How often should I test a private well in Armstrong County?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Sources

  • Texas Water Development Board Groundwater Database: 655 samples in Armstrong County. Water quality samples from the Texas Water Development Board Groundwater Database, collected by TWDB, groundwater conservation districts and cooperators. Retrieved September 9, 2026.
  • USGS Water Quality Portal: 2 samples in Armstrong County. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
  • TCEQ regulated sites: 4 regulated sites located in Armstrong County. Leaking petroleum storage tank sites, state Superfund sites and municipal solid waste landfills from the Texas Commission on Environmental Quality. Retrieved September 9, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.