Well Water Nerd

Well water in Erie County, Pennsylvania

1in4

Testing strongly recommended

tested well samples in Erie County exceeded the EPA limit for arsenic (10 ug/L), based on public data from USGS Water Quality Portal.

The strongest signal is total coliform: 52% of 146 local wells tested were above the EPA limit, too few samples to carry the headline but first on the test list below.

146 private wells tested 2008 to 2025 in state summaries; 1,626 test results across 14 contaminants from at least 366 wells, 1927 to 2024; chloride has the most at 443. Data refreshed September 16, 2026.

Compiled by Nick at Well Water Nerd from public records. How these pages are built

These are samples homeowners paid to send to the Penn State lab, often because of a suspected problem, so shares above the limit run higher than a random survey would find.

An estimated 84,384 people in Erie County get their drinking water from a private well, per USGS 2015 county water use. That is about 30% of residents.

Separately, the USGS national arsenic model estimates that 7% of the 84,384 people on private wells in Erie County draw water above 10 ug/L (the model's range is 5% to 10%), from geology and well depth rather than local tests.

What homeowner tests found

Penn State Agricultural Analytical Services Lab drinking water summaries: private wells tested and reported to the state, 2008 to 2025. Shares are against the level the state applies to each contaminant, named in the last column; several are stricter than EPA.

ContaminantAbove state levelWells testedMedian95th pctHighestState level
Total coliform14612010 MPN/100mL
Manganese602055050 ug/L
Iron611005,100300 ug/L
Arsenic782710 ug/L
Chloride1225.2430250 mg/L
E. coli1461650 MPN/100mL
Lead
(first draw)
904615 ug/L
Copper1090.011.531.3 mg/L
Nitrate
+ nitrite as N
790.27.310 mg/L
Sodium725.5138

What individual samples found

Each row summarizes every public sample for that contaminant inside Erie County. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.

ContaminantAbove limitSamplesDetectedMedianHighestLimit
Arsenic
1987 to 2024
8737%050510 ug/L
EPA limit
Lead
1964 to 2024
9538%060015 ug/L
EPA limit
E. coli
1998 to 2024
2814%060 MPN/100mL
EPA limit
Nitrate
1927 to 2024
20659%0.136.910 mg/L
EPA limit
Fluoride
1951 to 2024
12767%0.11.24 mg/L
EPA limit
Copper
1964 to 2024
3647%00.961.3 mg/L
EPA limit
Chloride
1927 to 2024
no limit443100%159,500250 mg/L
nuisance level
Iron
1927 to 2024
no limit32492%1751,170,000300 ug/L
nuisance level
Sodium
1928 to 2024
no limit133100%132,90020 mg/L
health guideline
Manganese
1964 to 2024
no limit12558%5020,600300 ug/L
health guideline
Radon
1996 to 2024
no limit10100%2256502,000 pCi/L
health guideline

Sampled fewer than 10 times, too few to summarize: Uranium (6), PFOS (3), PFOA (3).

Over time

Share of samples above the limit by period. A cell needs ten samples to show; a comparison needs twenty in each period. Later periods sample fewer wells, and often the ones already known to have a problem.

Contaminantbefore 20002000s2010s2020s
Nitrate4%154 samples8%40 samplesn/a0%12 samples

Nitrate has held within a few points between the two most recent periods with enough samples.

Closer than the county

See the sampled wells near your address

The same records, drawn around one point: which wells within a few miles were sampled and what they found, how deep the wells next to you were drilled, and any leaking tank or cleanup site within a mile.

Check my address

What this means

Among homeowners in Erie County who sent a sample to the state lab, the health-based limits most often exceeded were total coliform (52% of 146 wells), arsenic (13% of 78 wells), and E. coli (7% of 146 wells). These are ordinary wells tested by their owners, so the shares are the best available picture of a typical well here, with one caveat: people test more often when they suspect a problem.

Manganese and iron exceed the state's advisory level in a sizable share of wells; these are mostly a taste, staining or diet issue rather than a toxicity one.

What to test for in Erie County

  1. 1
    Total coliform
    52% of 146 local wells tested were above the EPA limit.
  2. 2
    Arsenic
    25% of 87 local samples were above the limit.
  3. 3
    Lead
    13% of 95 local samples were above the limit.
  4. 4
    E. coli
    11% of 28 local samples were above the limit.
  5. 5
    Nitrate
    4% of 206 local samples were above the limit.
  6. 6
    Copper
    <1% of 109 local wells tested were above the EPA limit.
  7. 7
    Radon
    Median local reading is 225 pCi/L.
  8. 8
    Manganese
    33% of 60 local wells tested were above the EPA secondary standard.

Test your Erie County well for total coliform, arsenic and lead

Certified lab analysis of your own tap water, bottles and prepaid return shipping included. The Essential well panel covers arsenic, uranium, nitrate, lead, copper, manganese, iron, sodium and bacteria; radon and PFAS are add-ons.

Order the Tap Score well water test kit, from $209Already tested? Upload the report

Just want bacteria checked first? Tap Score coliform and E. coli test, $99. Coliform and E. coli are the tests every well needs every year.

Want a quick look before paying for a lab? Home well water test strips on Amazon check hardness, iron, pH and nitrate in minutes. They are a screen, not a result: arsenic, bacteria, uranium and PFAS need a certified lab.

Affiliate links: the merchant pays us a commission and the price is the same for you. It does not change what the data above says. As an Amazon Associate we earn from qualifying purchases.

Where to get a well tested in Pennsylvania: certified labs, state programs and prices.

Already have results back? Get your lab report read against the Erie County numbers, $29. Every line explained, ranked by what matters, with the fix for each.

Wells in Erie County

6,212 domestic wells in Erie County are on record with the state. 89% are drilled into bedrock, and the typical well is 60 feet deep (one in ten goes past 100 feet).

In a typical Erie County well, bedrock starts about 23 feet down, the median yield is 7 gallons per minute, 19% of wells yield under 3 gallons per minute and usually need a storage tank.

Bedrock wells are where arsenic, uranium and radon come from: the water sits in fractures in granite and metamorphic rock and picks up whatever the rock carries. That is why testing for those three matters more here than in a dug or gravel well.

Find your own well's report

The state keeps the driller's report for most wells drilled since 1984. It tells you how deep your well is, where bedrock starts, and how much water it makes, which decides what treatment can work.

  1. Open PaGWIS (Pennsylvania Geological Survey) and choose Water Well.
  2. The record lists depth, depth to bedrock, yield and use; drillers have reported new wells to the state since 1966.

Pennsylvania has no private well construction standard and does not require testing, so many older wells have no record at all.

The rock under Erie County

Not a principal aquifer

The USGS map places this area outside any principal aquifer, which usually means wells here draw from fractured bedrock or thin local deposits rather than a large regional aquifer. Bedrock wells of that kind are where arsenic, radon and uranium turn up, and yields vary from well to well.

Classification from the USGS Principal Aquifers of the United States (national map, 2003 edition, GIS release 2015), read at the county centroid. A single well can sit in a different unit, especially near a boundary.

Official help in Pennsylvania

Two places to start that are not selling anything: the state program that answers private well questions, and its list of labs certified to run drinking water tests. A certified lab is the difference between a result you can act on and a number.

Treatment that fits the local profile

Total coliform

Inspect and repair the well cap and casing, then shock chlorinate and retest; UV disinfection whole-house; Chlorination system

Arsenic

Point-of-use reverse osmosis; Adsorptive media (iron-based) whole-house; Anion exchange

E. coli

Shock chlorination and fix the well cap or casing; UV disinfection whole-house; Chlorination system

Lead

Point-of-use reverse osmosis; Certified lead-removal carbon filter; Neutralizing filter to raise pH and stop leaching

Manganese

Oxidizing filter (greensand, birm) whole-house; Water softener (low levels); Point-of-use reverse osmosis

Nitrate

Point-of-use reverse osmosis; Anion exchange; Distillation

Systems we would look at first

Some links below are affiliate links. If you buy through one, the merchant pays us a commission at no extra cost to you. It does not change which products we list or what the data says.

For total coliform

Aquasana Rhino Well Water with UV

whole-house, at the point of entry, about $2,871

Whole-house system built for wells: sediment pre-filter, KDF and carbon, and a UV lamp rated to kill 99.99% of bacteria and viruses. It does not remove arsenic, nitrate, uranium or radon.

For arsenic

Under-sink reverse osmosis system

under-sink or countertop, about $300

Look for NSF/ANSI 58 certification listing the contaminant you need removed.

For arsenic

Whole-house arsenic and uranium filter

whole-house, at the point of entry, about $2,500

Adsorptive iron-based media; sized to your well yield.

For arsenic

Aquasana SmartFlow reverse osmosis

under-sink or countertop, about $225

Certified to NSF/ANSI 58 and 53 to reduce arsenic (96%, pentavalent), fluoride (90%), lead (99%), nitrate, nitrite and PFOA/PFOS at the kitchen tap, with a remineralizer.

For E. coli

UV disinfection system

whole-house, at the point of entry, about $900

Fix the well cap and casing first; UV keeps bacteria from returning.

For lead

Aquasana Claryum 3-Stage under-sink filter

under-sink or countertop, about $175

Certified to NSF/ANSI 53 to reduce 99% of lead and 99.7% of PFOA and PFOS at the tap. Not a fix for arsenic, nitrate or bacteria.

For lead

Acid neutralizing filter

whole-house, at the point of entry, about $1,200

Raises pH so plumbing stops leaching lead and copper.

Free, no obligation

Get on the list for a free in-home water test in Erie County

No water treatment company serves Erie County through Well Water Nerd yet. We are signing licensed companies on county by county: they test at your tap for free, walk you through the numbers, and quote treatment only if something needs fixing. Leave your details and you are first in line. Nothing is shared until a company joins for Erie County, and you get an email naming it first.

What are you worried about?

The test is free and there is no obligation. No company is named yet; your details stay with us until one joins for your area, and we log the time and address of this request.

Common questions

How deep are wells in Erie County?

The typical domestic well in Erie County is 60 feet deep, based on 6,212 wells reported to the state. One in ten is deeper than 100 feet. 89% are drilled into bedrock.

Is there arsenic in well water in Erie County?

Arsenic was detected in 37% of 87 public well samples in Erie County, and 25% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.

How high is radon in well water in Erie County?

The median radon level across 10 public samples in Erie County was 225 pCi/L, with a high of 650 pCi/L. New Hampshire recommends treatment above 2,000 pCi/L.

How often should I test a private well in Erie County?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Towns in Erie County

35 towns have fewer than 30 public samples and are included in the Erie County totals above rather than shown separately: Albion borough, Amity township, Concord township, Conneaut township, Corry, Cranesville borough, Edinboro borough, Elgin borough, Elk Creek township, Erie, Fairview township, Franklin township, Girard borough, Girard township, Greene township, Greenfield township, Lake City borough, Lawrence Park township, LeBoeuf township, McKean borough, McKean township, Mill Village borough, North East borough, Platea borough, Springfield township, Summit township, Union City borough, Union township, Venango township, Washington township, Waterford borough, Waterford township, Wattsburg borough, Wayne township, Wesleyville borough.

Counties near Erie County

Closest first. Groundwater does not stop at a line on a map, so the next county over is a fair second opinion.

Want the numbers themselves? Download the Pennsylvania dataset as CSV, every county and town, with the sources named.

Sources

  • USGS Water Quality Portal: 1,626 samples in Erie County. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
  • Penn State Agricultural Analytical Services Lab drinking water summaries: summaries for 10 contaminants in Erie County, up to 146 wells each. County summaries of private water samples tested by the Penn State Agricultural Analytical Services Laboratory since 2007, published by the College of Agricultural Sciences. Counts are samples, not distinct wells. Shares are against the standard the lab prints: the EPA maximum contaminant level, or the secondary standard for iron, manganese and chloride. Lead is the first-draw result. Medians printed as 0.00 are stored as null because the lab rounds to two decimals. Retrieved September 16, 2026.
  • USGS national arsenic model (Ayotte 2017): estimated share of 84,384 people on private wells in Erie County above 10 ug/L of arsenic, from geology, well depth and land use. County estimates of domestic well users with arsenic above 10 ug/L from the USGS national logistic regression model (Ayotte, Medalie and Qi, 2017), with private well population from the USGS 2015 county water-use compilation (Dieter and others, 2018). Retrieved September 15, 2026.
  • Pennsylvania Groundwater Information System (PaGWIS) wells: 7,806 well records in Erie County, 6,212 domestic. Water well records from the Pennsylvania Groundwater Information System, Pennsylvania Geological Survey (DCNR). Only aggregates are shown; owner names and addresses are never stored. Retrieved September 16, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.