Well Water Nerd

Well water in Clearfield County, Pennsylvania

In Clearfield County, 3% of 478 tested well samples exceeded the EPA limit for lead (15 ug/L), based on public data from USGS Water Quality Portal.

The strongest signal is total coliform: 71% of 142 local wells tested were above the EPA limit, too few samples to carry the headline but first on the test list below.

142 private wells tested 2008 to 2025 in state summaries; 4,459 test results across 15 contaminants from at least 56 wells, 1901 to 2026; iron has the most at 504. Data refreshed September 16, 2026.

Compiled by Nick at Well Water Nerd from public records. How these pages are built

These are samples homeowners paid to send to the Penn State lab, often because of a suspected problem, so shares above the limit run higher than a random survey would find.

An estimated 22,480 people in Clearfield County get their drinking water from a private well, per USGS 2015 county water use. That is about 28% of residents.

Separately, the USGS national arsenic model estimates that <1% of the 22,480 people on private wells in Clearfield County draw water above 10 ug/L, from geology and well depth rather than local tests.

What homeowner tests found

Penn State Agricultural Analytical Services Lab drinking water summaries: private wells tested and reported to the state, 2008 to 2025. Shares are against the level the state applies to each contaminant, named in the last column; several are stricter than EPA.

ContaminantAbove state levelWells testedMedian95th pctHighestState level
Total coliform14228.85170 MPN/100mL
Manganese772019,88050 ug/L
Iron5610093,800300 ug/L
E. coli1422010 MPN/100mL
Lead
(first draw)
554115 ug/L
Nitrate
+ nitrite as N
640.313.410 mg/L
Copper540.011.271.3 mg/L
Arsenic49510 ug/L
Chloride312117250 mg/L
Sodium171.0127.7

What individual samples found

Each row summarizes every public sample for that contaminant inside Clearfield County. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.

ContaminantAbove limitSamplesDetectedMedianHighestLimit
Lead
1901 to 2026
47847%02,00015 ug/L
EPA limit
Nitrate
1901 to 2026
49235%06610 mg/L
EPA limit
Copper
1901 to 2026
48778%0.030.661.3 mg/L
EPA limit
Arsenic
1901 to 2026
4836%0710 ug/L
EPA limit
Fluoride
1901 to 2026
48058%0.22.24 mg/L
EPA limit
Uranium
1996 to 2025
1217%00.06330 ug/L
EPA limit
Iron
1901 to 2026
no limit50499%56,500500,000300 ug/L
nuisance level
Manganese
1901 to 2026
no limit502100%38,000400,000300 ug/L
health guideline
Chloride
1901 to 2026
no limit49794%3920250 mg/L
nuisance level
Sodium
1901 to 2026
no limit494100%6.754020 mg/L
health guideline
Radon
1995 to 2025
no limit1593%1408202,000 pCi/L
health guideline

Sampled fewer than 10 times, too few to summarize: E. coli (5), PFOS (4), PFOA (4), Radium (226 + 228) (2).

Over time

Share of samples above the limit by period. A cell needs ten samples to show; a comparison needs twenty in each period. Later periods sample fewer wells, and often the ones already known to have a problem.

Contaminantbefore 20002000s2010s2020s
Nitrate<1%472 samplesn/an/a0%17 samples
Copper0%467 samplesn/an/a0%17 samples
Arsenic0%463 samplesn/an/a0%17 samples
Fluoride0%460 samplesn/an/a0%17 samples
Lead3%458 samplesn/an/a0%17 samples

Closer than the county

See the sampled wells near your address

The same records, drawn around one point: which wells within a few miles were sampled and what they found, how deep the wells next to you were drilled, and any leaking tank or cleanup site within a mile.

Check my address

What this means

Among homeowners in Clearfield County who sent a sample to the state lab, the health-based limits most often exceeded were total coliform (71% of 142 wells), E. coli (27% of 142 wells), and lead (5% of 55 wells). These are ordinary wells tested by their owners, so the shares are the best available picture of a typical well here, with one caveat: people test more often when they suspect a problem.

Manganese and iron exceed the state's advisory level in a sizable share of wells; these are mostly a taste, staining or diet issue rather than a toxicity one.

What to test for in Clearfield County

  1. 1
    Total coliform
    71% of 142 local wells tested were above the EPA limit.
  2. 2
    E. coli
    27% of 142 local wells tested were above the EPA limit.
  3. 3
    Lead
    5% of 55 local wells tested were above the EPA limit.
  4. 4
    Nitrate
    3% of 64 local wells tested were above the EPA limit.
  5. 5
    Radon
    Median local reading is 140 pCi/L.
  6. 6
    Manganese
    39% of 77 local wells tested were above the EPA secondary standard.
  7. 7
    Iron
    32% of 56 local wells tested were above the EPA secondary standard.
  8. 8
    Chloride
    Detected in 94% of local samples.

Test your Clearfield County well for total coliform, E. coli and lead

Certified lab analysis of your own tap water, bottles and prepaid return shipping included. The Essential well panel covers arsenic, uranium, nitrate, lead, copper, manganese, iron, sodium and bacteria; radon and PFAS are add-ons.

Order the Tap Score well water test kit, from $209Already tested? Upload the report

Just want bacteria checked first? Tap Score coliform and E. coli test, $99. Coliform and E. coli are the tests every well needs every year.

Want a quick look before paying for a lab? Home well water test strips on Amazon check hardness, iron, pH and nitrate in minutes. They are a screen, not a result: arsenic, bacteria, uranium and PFAS need a certified lab.

Affiliate links: the merchant pays us a commission and the price is the same for you. It does not change what the data above says. As an Amazon Associate we earn from qualifying purchases.

Where to get a well tested in Pennsylvania: certified labs, state programs and prices.

Already have results back? Get your lab report read against the Clearfield County numbers, $29. Every line explained, ranked by what matters, with the fix for each.

Wells in Clearfield County

1,111 domestic wells in Clearfield County are on record with the state. 100% are drilled into bedrock, and the typical well is 170 feet deep (one in ten goes past 320 feet).

In a typical Clearfield County well, bedrock starts about 27 feet down, the median yield is 10 gallons per minute, 11% of wells yield under 3 gallons per minute and usually need a storage tank.

Bedrock wells are where arsenic, uranium and radon come from: the water sits in fractures in granite and metamorphic rock and picks up whatever the rock carries. That is why testing for those three matters more here than in a dug or gravel well.

Find your own well's report

The state keeps the driller's report for most wells drilled since 1984. It tells you how deep your well is, where bedrock starts, and how much water it makes, which decides what treatment can work.

  1. Open PaGWIS (Pennsylvania Geological Survey) and choose Water Well.
  2. The record lists depth, depth to bedrock, yield and use; drillers have reported new wells to the state since 1966.

Pennsylvania has no private well construction standard and does not require testing, so many older wells have no record at all.

The rock under Clearfield County

Pennsylvanian aquifers

Sandstone. Sandstone wells draw from pore space in the rock and tend to be dependable. Iron, manganese and hardness are common, and some sandstones carry arsenic or radium, so a first test should include both.

Classification from the USGS Principal Aquifers of the United States (national map, 2003 edition, GIS release 2015), read at the county centroid. A single well can sit in a different unit, especially near a boundary.

Official help in Pennsylvania

Two places to start that are not selling anything: the state program that answers private well questions, and its list of labs certified to run drinking water tests. A certified lab is the difference between a result you can act on and a number.

Treatment that fits the local profile

Total coliform

Inspect and repair the well cap and casing, then shock chlorinate and retest; UV disinfection whole-house; Chlorination system

E. coli

Shock chlorination and fix the well cap or casing; UV disinfection whole-house; Chlorination system

Lead

Point-of-use reverse osmosis; Certified lead-removal carbon filter; Neutralizing filter to raise pH and stop leaching

Manganese

Oxidizing filter (greensand, birm) whole-house; Water softener (low levels); Point-of-use reverse osmosis

Iron

Oxidizing filter whole-house; Water softener (low levels); Aeration plus filtration

Nitrate

Point-of-use reverse osmosis; Anion exchange; Distillation

Systems we would look at first

Some links below are affiliate links. If you buy through one, the merchant pays us a commission at no extra cost to you. It does not change which products we list or what the data says.

For total coliform

Aquasana Rhino Well Water with UV

whole-house, at the point of entry, about $2,871

Whole-house system built for wells: sediment pre-filter, KDF and carbon, and a UV lamp rated to kill 99.99% of bacteria and viruses. It does not remove arsenic, nitrate, uranium or radon.

For E. coli

UV disinfection system

whole-house, at the point of entry, about $900

Fix the well cap and casing first; UV keeps bacteria from returning.

For lead

Under-sink reverse osmosis system

under-sink or countertop, about $300

Look for NSF/ANSI 58 certification listing the contaminant you need removed.

For lead

Acid neutralizing filter

whole-house, at the point of entry, about $1,200

Raises pH so plumbing stops leaching lead and copper.

For lead

Aquasana SmartFlow reverse osmosis

under-sink or countertop, about $225

Certified to NSF/ANSI 58 and 53 to reduce arsenic (96%, pentavalent), fluoride (90%), lead (99%), nitrate, nitrite and PFOA/PFOS at the kitchen tap, with a remineralizer.

For manganese

Iron and manganese oxidizing filter

whole-house, at the point of entry, about $1,800

Air-injection or greensand media; fixes staining at the source.

Free, no obligation

Get on the list for a free in-home water test in Clearfield County

No water treatment company serves Clearfield County through Well Water Nerd yet. We are signing licensed companies on county by county: they test at your tap for free, walk you through the numbers, and quote treatment only if something needs fixing. Leave your details and you are first in line. Nothing is shared until a company joins for Clearfield County, and you get an email naming it first.

What are you worried about?

The test is free and there is no obligation. No company is named yet; your details stay with us until one joins for your area, and we log the time and address of this request.

Common questions

How deep are wells in Clearfield County?

The typical domestic well in Clearfield County is 170 feet deep, based on 1,111 wells reported to the state. One in ten is deeper than 320 feet. 100% are drilled into bedrock.

Is there arsenic in well water in Clearfield County?

Arsenic was detected in 6% of 483 public well samples in Clearfield County, and 0% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.

How high is radon in well water in Clearfield County?

The median radon level across 15 public samples in Clearfield County was 140 pCi/L, with a high of 820 pCi/L. New Hampshire recommends treatment above 2,000 pCi/L.

How often should I test a private well in Clearfield County?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Towns in Clearfield County

49 towns have fewer than 30 public samples and are included in the Clearfield County totals above rather than shown separately: Beccaria township, Bell township, Bigler township, Bloom township, Bradford township, Brady township, Brisbin borough, Burnside borough, Burnside township, Chester Hill borough, Chest township, Clearfield borough, Coalport borough, Cooper township, Covington township, Curwensville borough, Decatur township, DuBois, Falls Creek borough, Ferguson township, Girard township, Glen Hope borough, Goshen township, Graham township, Grampian borough, Greenwood township, Gulich township, Houtzdale borough, Huston township, Irvona borough, Jordan township, Karthaus township, Knox township, Lawrence township, Mahaffey borough, Morris township, Newburg borough, New Washington borough, Osceola Mills borough, Penn township, Pike township, Pine township, Ramey borough, Sandy township, Troutville borough, Union township, Wallaceton borough, Westover borough, Woodward township.

Counties near Clearfield County

Closest first. Groundwater does not stop at a line on a map, so the next county over is a fair second opinion.

Want the numbers themselves? Download the Pennsylvania dataset as CSV, every county and town, with the sources named.

Sources

  • USGS Water Quality Portal: 4,459 samples in Clearfield County. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
  • Penn State Agricultural Analytical Services Lab drinking water summaries: summaries for 10 contaminants in Clearfield County, up to 142 wells each. County summaries of private water samples tested by the Penn State Agricultural Analytical Services Laboratory since 2007, published by the College of Agricultural Sciences. Counts are samples, not distinct wells. Shares are against the standard the lab prints: the EPA maximum contaminant level, or the secondary standard for iron, manganese and chloride. Lead is the first-draw result. Medians printed as 0.00 are stored as null because the lab rounds to two decimals. Retrieved September 16, 2026.
  • USGS national arsenic model (Ayotte 2017): estimated share of 22,480 people on private wells in Clearfield County above 10 ug/L of arsenic, from geology, well depth and land use. County estimates of domestic well users with arsenic above 10 ug/L from the USGS national logistic regression model (Ayotte, Medalie and Qi, 2017), with private well population from the USGS 2015 county water-use compilation (Dieter and others, 2018). Retrieved September 15, 2026.
  • Pennsylvania Groundwater Information System (PaGWIS) wells: 2,388 well records in Clearfield County, 1,111 domestic. Water well records from the Pennsylvania Groundwater Information System, Pennsylvania Geological Survey (DCNR). Only aggregates are shown; owner names and addresses are never stored. Retrieved September 16, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.