Well Water Nerd

Well water in Upper Pittsgrove township, New Jersey

In Upper Pittsgrove township, 19% of 521 private wells tested between 2002 and 2024 had nitrate above the New Jersey limit (10 mg/L), according to NJDEP.

521 private wells tested 2002 to 2024 in state summaries; 43 individual samples from 22 wells, 1985 to 2023. Data refreshed September 9, 2026.

What homeowner tests found

NJDEP Private Well Testing Act summaries: private wells tested and reported to the state, 2002 to 2024. Shares are against the level the state applies to each contaminant, named in the last column; several are stricter than EPA.

ContaminantWells testedAbove state levelMedian95th pctHighestState level
Iron52130%300 ug/L
Gross alpha50927%15 pCi/L
Manganese52124%50 ug/L
Nitrate52119%10 mg/L
Total coliform51712%
PFOA929%14 ng/L
PFOS923%13 ng/L
E. coli
Fecal coliform or
517<1%
Arsenic1890%5 ug/L
PFNA920%13 ng/L

What individual samples found

Each row summarizes every public sample for that contaminant inside Upper Pittsgrove township. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.

ContaminantSamplesDetectedAbove limitMedianHighestLimit
Arsenic
1985 to 2023
4347%0%0710 ug/L
EPA limit
Radium (226 + 228)
1988 to 1998
3768%0%0.454.85 pCi/L
EPA limit
Uranium
1988 to 2004
2162%0%0.020.3630 ug/L
EPA limit
Radon
1990 to 1998
23100%no limit3701,3002,000 pCi/L
health guideline

Sampled fewer than 10 times, too few to summarize: PFOA (6), Nitrate (2), PFOS (6), Lead (1), Copper (1), Fluoride (1), Iron (1).

Get the free Upper Pittsgrove township well report

One email with the numbers above, what they mean for a home in Upper Pittsgrove township, exactly which tests to order, and what treatment fits the local profile. No spam, unsubscribe in one click.

What this means

Among homeowners in Upper Pittsgrove township who sent a sample to the state lab, the health-based limits most often exceeded were nitrate (19% of 521 wells), total coliform (12% of 517 wells), and PFOA (9% of 92 wells). These are ordinary wells tested by their owners, so the shares are the best available picture of a typical well here, with one caveat: people test more often when they suspect a problem.

Iron and manganese exceed the state's advisory level in a sizable share of wells; these are mostly a taste, staining or diet issue rather than a toxicity one.

What to test for in Upper Pittsgrove township

  • Iron30% of 521 local wells tested were above the New Jersey nuisance level.
  • Gross alpha27% of 509 local wells tested were above the New Jersey limit.
  • Manganese24% of 521 local wells tested were above the New Jersey nuisance level.
  • Nitrate19% of 521 local wells tested were above the New Jersey limit.
  • Total coliform12% of 517 local wells tested were above the New Jersey limit (any detection).
  • PFOA9% of 92 local wells tested were above the New Jersey limit.
  • PFOS3% of 92 local wells tested were above the New Jersey limit.
  • E. coli<1% of 517 local wells tested were above the New Jersey limit (any detection).

Contamination sources on record in Upper Pittsgrove township

NJDEP records 27 regulated sites in Upper Pittsgrove township, among 27 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.

23
registered underground storage tank sitesRegistered tanks are regulated and inspected; they matter most when they are old or near a shallow well.
1
lined landfill or transfer facility
3
other remediation projects

Treatment that fits the local profile

Nitrate
Point-of-use reverse osmosis; Anion exchange; Distillation
Total coliform
Inspect and repair the well cap and casing, then shock chlorinate and retest; UV disinfection whole-house; Chlorination system
PFOA
Granular activated carbon whole-house; Point-of-use reverse osmosis; Anion exchange
Gross alpha
Point-of-use reverse osmosis; Water softener (cation exchange) for radium; Anion exchange for uranium
Iron
Oxidizing filter whole-house; Water softener (low levels); Aeration plus filtration
Fluoride
Point-of-use reverse osmosis; Activated alumina; Distillation

Get your Upper Pittsgrove township water tested at home

A licensed local water treatment company tests your tap water in your home, walks you through the numbers, and quotes treatment only if something needs fixing. Free, about 30 minutes, no obligation. Tell us what you need and we match you with a company that serves Upper Pittsgrove township.

What are you worried about?

The test is free and there is no obligation. Your details go only to the company named above, and we log the time and address of this request.

Common questions

Is there arsenic in well water in Upper Pittsgrove township?

Arsenic was detected in 47% of 43 public well samples in Upper Pittsgrove township, and 0% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.

How high is radon in well water in Upper Pittsgrove township?

The median radon level across 23 public samples in Upper Pittsgrove township was 370 pCi/L, with a high of 1,300 pCi/L. New Hampshire recommends treatment above 2,000 pCi/L.

How often should I test a private well in Upper Pittsgrove township?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Sources

  • USGS Water Quality Portal: 142 samples in Upper Pittsgrove township. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
  • NJDEP Private Well Testing Act summaries: summaries for 10 contaminants in Upper Pittsgrove township, up to 521 wells each. Share of private wells exceeding each standard in tests required at sale or lease under the New Jersey Private Well Testing Act, September 2002 to December 2024, published by NJDEP. Tests are untreated water at the time of sale or lease, so every well is counted once per transaction. Municipalities with fewer than ten wells are suppressed. Standards are New Jersey's: arsenic 5 ug/L, PFOA 14 ng/L, PFOS 13 ng/L, PFNA 13 ng/L, manganese and iron secondary standards. Uranium and PFAS were added to the required panel in 2021 and 2020, so their well counts are smaller. Retrieved September 9, 2026.
  • NJDEP regulated sites: 27 regulated sites located in Upper Pittsgrove township. Known Contaminated Sites, regulated underground storage tank facilities and solid waste landfills from the New Jersey Department of Environmental Protection (NJ-GeoWeb). Retrieved September 9, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.