Well Water Nerd

Well water in Kingwood township, New Jersey

1in2

Testing strongly recommended

private wells tested between 2002 and 2024 in Kingwood township had arsenic above the New Jersey limit (5 ug/L), according to NJDEP.

688 private wells tested 2002 to 2024 in state summaries; 178 test results across 11 contaminants from at least 12 wells, 1968 to 2025; iron has the most at 28. Data refreshed September 9, 2026.

Compiled by Nick at Well Water Nerd from public records. How these pages are built

What homeowner tests found

NJDEP Private Well Testing Act summaries: private wells tested and reported to the state, 2002 to 2024. Shares are against the level the state applies to each contaminant, named in the last column; several are stricter than EPA.

ContaminantAbove state levelWells testedMedian95th pctHighestState level
Arsenic6885 ug/L
Manganese68850 ug/L
Iron687300 ug/L
Total coliform687
Gross alpha61715 pCi/L
E. coli
Fecal coliform or
685
Uranium18030 ug/L
Nitrate68810 mg/L
PFNA9613 ng/L
PFOS9613 ng/L
PFOA9614 ng/L

What individual samples found

Each row summarizes every public sample for that contaminant inside Kingwood township. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.

ContaminantAbove limitSamplesDetectedMedianHighestLimit
Arsenic
1988 to 2025
2190%7.225.310 ug/L
EPA limit
Lead
1985 to 2025
2361%0.0611015 ug/L
EPA limit
Nitrate
1988 to 2025
2195%29.510 mg/L
EPA limit
Uranium
1985 to 2012
17100%2.21630 ug/L
EPA limit
Iron
1968 to 2025
no limit2871%6.453,500300 ug/L
nuisance level
Sodium
1968 to 2025
no limit27100%29.824020 mg/L
health guideline
Manganese
1968 to 2025
no limit2774%1.86820300 ug/L
health guideline

Sampled fewer than 10 times, too few to summarize: Radium (226 + 228) (7), PFOA (2), PFOS (2), Radon (3).

Closer than the town

See the sampled wells near your address

The same records, drawn around one point: which wells within a few miles were sampled and what they found, how deep the wells next to you were drilled, and any leaking tank or cleanup site within a mile.

Check my address

What this means

Among homeowners in Kingwood township who sent a sample to the state lab, the health-based limits most often exceeded were arsenic (43% of 688 wells), total coliform (21% of 687 wells), and E. coli (3% of 685 wells). These are ordinary wells tested by their owners, so the shares are the best available picture of a typical well here, with one caveat: people test more often when they suspect a problem.

Manganese and iron exceed the state's advisory level in a sizable share of wells; these are mostly a taste, staining or diet issue rather than a toxicity one.

What to test for in Kingwood township

  1. 1
    Arsenic
    43% of 688 local wells tested were above the New Jersey limit.
  2. 2
    Total coliform
    21% of 687 local wells tested were above the New Jersey limit (any detection).
  3. 3
    E. coli
    3% of 685 local wells tested were above the New Jersey limit (any detection).
  4. 4
    Uranium
    <1% of 180 local wells tested were above the New Jersey limit.
  5. 5
    Nitrate
    <1% of 688 local wells tested were above the New Jersey limit.
  6. 6
    Gross alpha
    13% of 617 local wells tested were above the New Jersey limit.
  7. 7
    Radon
    Median local reading is 2,340 pCi/L.
  8. 8
    Manganese
    27% of 688 local wells tested were above the New Jersey nuisance level.
  9. 9
    Volatile organic compounds (VOCs)
    1 hazardous waste site on record locally.
  10. 10
    Metals panel
    1 hazardous waste site on record locally.

Test your Kingwood township well for arsenic, total coliform and E. coli

Certified lab analysis of your own tap water, bottles and prepaid return shipping included. The Essential well panel covers arsenic, uranium, nitrate, lead, copper, manganese, iron, sodium and bacteria; radon and PFAS are add-ons.

Order the Tap Score well water test kit, from $209Already tested? Upload the report

Just want bacteria checked first? Tap Score coliform and E. coli test, $99. Coliform and E. coli are the tests every well needs every year.

Want a quick look before paying for a lab? Home well water test strips on Amazon check hardness, iron, pH and nitrate in minutes. They are a screen, not a result: arsenic, bacteria, uranium and PFAS need a certified lab.

Affiliate links: the merchant pays us a commission and the price is the same for you. It does not change what the data above says. As an Amazon Associate we earn from qualifying purchases.

Where to get a well tested in New Jersey: certified labs, state programs and prices.

Already have results back? Get your lab report read against the Kingwood township numbers, $29. Every line explained, ranked by what matters, with the fix for each.

The rock under Kingwood township

Early Mesozoic basin aquifers

Sandstone. Sandstone wells draw from pore space in the rock and tend to be dependable. Iron, manganese and hardness are common, and some sandstones carry arsenic or radium, so a first test should include both.

Classification from the USGS Principal Aquifers of the United States (national map, 2003 edition, GIS release 2015), read at the town centroid. A single well can sit in a different unit, especially near a boundary.

Official help in New Jersey

Two places to start that are not selling anything: the state program that answers private well questions, and its list of labs certified to run drinking water tests. A certified lab is the difference between a result you can act on and a number.

Contamination sources on record in Kingwood township

NJDEP records 1 hazardous waste site in Kingwood township, among 24 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.

1
hazardous waste siteSolvents, degreasers and metals from industrial sites can travel far in fractured bedrock.
20
registered underground storage tank sitesRegistered tanks are regulated and inspected; they matter most when they are old or near a shallow well.
3
other remediation projects

Treatment that fits the local profile

Arsenic

Point-of-use reverse osmosis; Adsorptive media (iron-based) whole-house; Anion exchange

Total coliform

Inspect and repair the well cap and casing, then shock chlorinate and retest; UV disinfection whole-house; Chlorination system

Gross alpha

Point-of-use reverse osmosis; Water softener (cation exchange) for radium; Anion exchange for uranium

Manganese

Oxidizing filter (greensand, birm) whole-house; Water softener (low levels); Point-of-use reverse osmosis

Iron

Oxidizing filter whole-house; Water softener (low levels); Aeration plus filtration

Radon

Aeration (bubble-up or diffused) whole-house; Granular activated carbon whole-house (lower levels only)

Systems we would look at first

Some links below are affiliate links. If you buy through one, the merchant pays us a commission at no extra cost to you. It does not change which products we list or what the data says.

For arsenic

Under-sink reverse osmosis system

under-sink or countertop, about $300

Look for NSF/ANSI 58 certification listing the contaminant you need removed.

For arsenic

Whole-house arsenic and uranium filter

whole-house, at the point of entry, about $2,500

Adsorptive iron-based media; sized to your well yield.

For arsenic

Aquasana SmartFlow reverse osmosis

under-sink or countertop, about $225

Certified to NSF/ANSI 58 and 53 to reduce arsenic (96%, pentavalent), fluoride (90%), lead (99%), nitrate, nitrite and PFOA/PFOS at the kitchen tap, with a remineralizer.

For total coliform

Aquasana Rhino Well Water with UV

whole-house, at the point of entry, about $2,871

Whole-house system built for wells: sediment pre-filter, KDF and carbon, and a UV lamp rated to kill 99.99% of bacteria and viruses. It does not remove arsenic, nitrate, uranium or radon.

For manganese

Iron and manganese oxidizing filter

whole-house, at the point of entry, about $1,800

Air-injection or greensand media; fixes staining at the source.

Free, no obligation

Get on the list for a free in-home water test in Kingwood township

No water treatment company serves Kingwood township through Well Water Nerd yet. We are signing licensed companies on county by county: they test at your tap for free, walk you through the numbers, and quote treatment only if something needs fixing. Leave your details and you are first in line. Nothing is shared until a company joins for Kingwood township, and you get an email naming it first.

What are you worried about?

The test is free and there is no obligation. No company is named yet; your details stay with us until one joins for your area, and we log the time and address of this request.

Common questions

Is there arsenic in well water in Kingwood township?

Arsenic was detected in 90% of 21 public well samples in Kingwood township, and 14% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.

How often should I test a private well in Kingwood township?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Towns near Kingwood township

Closest first. Groundwater does not stop at a line on a map, so the next town over is a fair second opinion.

Want the numbers themselves? Download the New Jersey dataset as CSV, every county and town, with the sources named.

Sources

  • USGS Water Quality Portal: 178 samples in Kingwood township. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
  • NJDEP Private Well Testing Act summaries: summaries for 11 contaminants in Kingwood township, up to 688 wells each. Share of private wells exceeding each standard in tests required at sale or lease under the New Jersey Private Well Testing Act, September 2002 to December 2024, published by NJDEP. Tests are untreated water at the time of sale or lease, so every well is counted once per transaction. Municipalities with fewer than ten wells are suppressed. Standards are New Jersey's: arsenic 5 ug/L, PFOA 14 ng/L, PFOS 13 ng/L, PFNA 13 ng/L, manganese and iron secondary standards. Uranium and PFAS were added to the required panel in 2021 and 2020, so their well counts are smaller. Retrieved September 9, 2026.
  • NJDEP regulated sites: 24 regulated sites located in Kingwood township. Known Contaminated Sites, regulated underground storage tank facilities and solid waste landfills from the New Jersey Department of Environmental Protection (NJ-GeoWeb). Retrieved September 9, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.