In Shiloh borough, 29% of 103 private wells tested between 2002 and 2024 had nitrate above the New Jersey limit (10 mg/L), according to NJDEP.

103 private wells tested 2002 to 2024 in state summaries; 3 individual samples from 1 wells, 1999 to 2009. Data refreshed September 9, 2026.

What homeowner tests found

NJDEP Private Well Testing Act summaries: private wells tested and reported to the state, 2002 to 2024. Shares are against the level the state applies to each contaminant, named in the last column; several are stricter than EPA.

ContaminantWells testedAbove state levelMedian95th pctHighestState level
Gross alpha9967%15 pCi/L
Nitrate10329%10 mg/L
Iron10317%300 ug/L
Total coliform1038%
Manganese1035%50 ug/L
E. coli
Fecal coliform or
1030%
Arsenic360%5 ug/L
PFNA140%13 ng/L
PFOS140%13 ng/L
PFOA140%14 ng/L

Get the free Shiloh borough well report

One email with the numbers above, what they mean for a home in Shiloh borough, exactly which tests to order, and what treatment fits the local profile. No spam, unsubscribe in one click.

What this means

Among homeowners in Shiloh borough who sent a sample to the state lab, the health-based limits most often exceeded were nitrate (29% of 103 wells) and total coliform (8% of 103 wells). These are ordinary wells tested by their owners, so the shares are the best available picture of a typical well here, with one caveat: people test more often when they suspect a problem.

Iron exceeds the state's advisory level in a sizable share of wells; this is mostly a taste, staining or diet issue rather than a toxicity one.

What to test for in Shiloh borough

  • Gross alpha67% of 99 local wells tested were above the New Jersey limit.
  • Nitrate29% of 103 local wells tested were above the New Jersey limit.
  • Iron17% of 103 local wells tested were above the New Jersey nuisance level.
  • Total coliform8% of 103 local wells tested were above the New Jersey limit (any detection).
  • Manganese5% of 103 local wells tested were above the New Jersey nuisance level.
  • Coliform bacteriaRecommended for every private well, every year.

Contamination sources on record in Shiloh borough

NJDEP records 5 regulated sites in Shiloh borough, among 5 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.

5
registered underground storage tank sitesRegistered tanks are regulated and inspected; they matter most when they are old or near a shallow well.

Treatment that fits the local profile

Nitrate
Point-of-use reverse osmosis; Anion exchange; Distillation
Total coliform
Inspect and repair the well cap and casing, then shock chlorinate and retest; UV disinfection whole-house; Chlorination system
Gross alpha
Point-of-use reverse osmosis; Water softener (cation exchange) for radium; Anion exchange for uranium
Iron
Oxidizing filter whole-house; Water softener (low levels); Aeration plus filtration

Get your Shiloh borough water tested at home

A licensed local water treatment company tests your tap water in your home, walks you through the numbers, and quotes treatment only if something needs fixing. Free, about 30 minutes, no obligation. Tell us what you need and we match you with a company that serves Shiloh borough.

What are you worried about?

The test is free and there is no obligation. Your details go only to the company named above, and we log the time and address of this request.

Common questions

Is there arsenic in well water in Shiloh borough?

Arsenic was detected in 33% of 3 public well samples in Shiloh borough, and 0% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.

How often should I test a private well in Shiloh borough?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Sources

  • USGS Water Quality Portal: 3 samples in Shiloh borough. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
  • NJDEP Private Well Testing Act summaries: summaries for 10 contaminants in Shiloh borough, up to 103 wells each. Share of private wells exceeding each standard in tests required at sale or lease under the New Jersey Private Well Testing Act, September 2002 to December 2024, published by NJDEP. Tests are untreated water at the time of sale or lease, so every well is counted once per transaction. Municipalities with fewer than ten wells are suppressed. Standards are New Jersey's: arsenic 5 ug/L, PFOA 14 ng/L, PFOS 13 ng/L, PFNA 13 ng/L, manganese and iron secondary standards. Uranium and PFAS were added to the required panel in 2021 and 2020, so their well counts are smaller. Retrieved September 9, 2026.
  • NJDEP regulated sites: 5 regulated sites located in Shiloh borough. Known Contaminated Sites, regulated underground storage tank facilities and solid waste landfills from the New Jersey Department of Environmental Protection (NJ-GeoWeb). Retrieved September 9, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.