Well water in Woodbury, Connecticut
1in12
Testing recommended
tested well samples in Woodbury exceeded the EPA limit for nitrate (10 mg/L), based on public data from USGS Water Quality Portal and Connecticut DPH and USGS arsenic and uranium survey.
1,292 test results across 13 contaminants from at least 76 wells, 1962 to 2015; nitrate has the most at 245. Data refreshed September 3, 2026.
Compiled by Nick at Well Water Nerd from public records. How these pages are built
What individual samples found
Each row summarizes every public sample for that contaminant inside Woodbury. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.
| Contaminant | Above limit | Samples | Detected | Median | Highest | Limit |
|---|---|---|---|---|---|---|
| Nitrate 1966 to 2011 | 245 | 87% | 1.64 | 84.2 | 10 mg/L EPA limit | |
| Fluoride 1966 to 2011 | 112 | 34% | 0 | 0.35 | 4 mg/L EPA limit | |
| Arsenic 1979 to 2015 | 84 | 38% | 0 | 5.8 | 10 ug/L EPA limit | |
| Copper 1981 to 2011 | 73 | 68% | 0.001 | 0.03 | 1.3 mg/L EPA limit | |
| Lead 1981 to 2011 | 73 | 36% | 0 | 1.58 | 15 ug/L EPA limit | |
| Radium (226 + 228) 2003 to 2006 | 64 | 61% | 0.044 | 0.95 | 5 pCi/L EPA limit | |
| Uranium 2002 to 2015 | 52 | 88% | 0.092 | 27 | 30 ug/L EPA limit | |
| Chloride 1966 to 2011 | no limit | 151 | 100% | 23 | 400 | 250 mg/L nuisance level |
| Sodium 1966 to 2011 | no limit | 137 | 100% | 14 | 93.9 | 20 mg/L health guideline |
| Manganese 1962 to 2011 | no limit | 129 | 96% | 6.61 | 15,800 | 300 ug/L health guideline |
| Iron 1962 to 2011 | no limit | 129 | 76% | 7.2 | 26,500 | 300 ug/L nuisance level |
| Radon 2002 to 2005 | no limit | 37 | 100% | 1,140 | 13,200 | 2,000 pCi/L health guideline |
Sampled fewer than 10 times, too few to summarize: E. coli (6).
Over time
Share of samples above the limit by period. A cell needs ten samples to show; a comparison needs twenty in each period. Later periods sample fewer wells, and often the ones already known to have a problem.
| Contaminant | before 2000 | 2000s | 2010s | 2020s |
|---|---|---|---|---|
| Nitrate | 4%57 samples | 10%186 samples | n/a | n/a |
| Fluoride | 0%17 samples | 0%94 samples | n/a | n/a |
| Arsenic | 0%32 samples | 0%46 samples | n/a | n/a |
| Copper | 0%26 samples | 0%46 samples | n/a | n/a |
| Lead | 0%26 samples | 0%46 samples | n/a | n/a |
Nitrate above the limit in Woodbury rose from 4% of 57 samples before 2000 to 10% of 186 in the 2000s.
Arsenic, copper, lead have held within a few points between the two most recent periods with enough samples.
Closer than the town
See the sampled wells near your address
The same records, drawn around one point: which wells within a few miles were sampled and what they found, how deep the wells next to you were drilled, and any leaking tank or cleanup site within a mile.
Check my addressWhat this means
The contaminants most often above their limit here are nitrate (8% of 245 samples). A well next door can differ sharply from yours because bedrock fractures, well depth and plumbing all matter, so these rates describe the area, not your tap.
Chloride, Manganese, and Iron are widespread in local groundwater. They are mainly a staining and taste problem, but high manganese also carries a health advisory for infants.
What to test for in Woodbury
- 1Nitrate8% of 245 local samples were above the limit.
- 2Coliform bacteriaRecommended for every private well, every year.
- 3RadonMedian local reading is 1,140 pCi/L.
- 4ChlorideDetected in 100% of local samples.
- 5ManganeseDetected in 96% of local samples.
- 6IronDetected in 76% of local samples.
- 7CopperDetected in 68% of local samples.
- 8Volatile organic compounds (VOCs)22 leaking underground storage tank sites on record locally.
Test your Woodbury well for nitrate, coliform bacteria and radon
Certified lab analysis of your own tap water, bottles and prepaid return shipping included. The Essential well panel covers arsenic, uranium, nitrate, lead, copper, manganese, iron, sodium and bacteria; radon and PFAS are add-ons.
Order the Tap Score well water test kit, from $209Already tested? Upload the report
Just want bacteria checked first? Tap Score coliform and E. coli test, $99. Coliform and E. coli are the tests every well needs every year.
Want a quick look before paying for a lab? Home well water test strips on Amazon check hardness, iron, pH and nitrate in minutes. They are a screen, not a result: arsenic, bacteria, uranium and PFAS need a certified lab.
Affiliate links: the merchant pays us a commission and the price is the same for you. It does not change what the data above says. As an Amazon Associate we earn from qualifying purchases.
Where to get a well tested in Connecticut: certified labs, state programs and prices.
Already have results back? Get your lab report read against the Woodbury numbers, $29. Every line explained, ranked by what matters, with the fix for each.
Wells in Woodbury
29 domestic wells in Woodbury are on record with the state since 1926. the typical well is 500 feet deep (one in ten goes past 701 feet).
In a typical Woodbury well, the median yield is 4 gallons per minute, 41% of wells yield under 3 gallons per minute and usually need a storage tank.
Find your own well's report
The state keeps the driller's report for most wells drilled since 1984. It tells you how deep your well is, where bedrock starts, and how much water it makes, which decides what treatment can work.
- Open Connecticut well completion reports and choose Water Well.
- The report lists depth, depth to rock, casing, static water level and yield.
Only reports filed online since January 2021 are here; older paper reports are held by the Department of Consumer Protection.
The rock under Woodbury
Not a principal aquifer
The USGS map places this area outside any principal aquifer, which usually means wells here draw from fractured bedrock or thin local deposits rather than a large regional aquifer. Bedrock wells of that kind are where arsenic, radon and uranium turn up, and yields vary from well to well.
Classification from the USGS Principal Aquifers of the United States (national map, 2003 edition, GIS release 2015), read at the town centroid. A single well can sit in a different unit, especially near a boundary.
Official help in Connecticut
Two places to start that are not selling anything: the state program that answers private well questions, and its list of labs certified to run drinking water tests. A certified lab is the difference between a result you can act on and a number.
- Private Wells, CT DPH
- Environmental Laboratory Certification, CT DPH
Contamination sources on record in Woodbury
CT DEEP contaminated sites and landfills records 22 leaking underground storage tank sites in Woodbury, among 41 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.
- 22
- leaking underground storage tank sitesGasoline and heating oil that leaked from tanks move through groundwater as benzene, MTBE and other volatile organic compounds.
- 1
- lined landfill or transfer facility
- 18
- other remediation projects
Treatment that fits the local profile
Nitrate
Point-of-use reverse osmosis; Anion exchange; Distillation
Manganese
Oxidizing filter (greensand, birm) whole-house; Water softener (low levels); Point-of-use reverse osmosis
Iron
Oxidizing filter whole-house; Water softener (low levels); Aeration plus filtration
Systems we would look at first
Some links below are affiliate links. If you buy through one, the merchant pays us a commission at no extra cost to you. It does not change which products we list or what the data says.
For nitrate
Under-sink reverse osmosis system
under-sink or countertop, about $300
Look for NSF/ANSI 58 certification listing the contaminant you need removed.
For nitrate
Aquasana SmartFlow reverse osmosis
under-sink or countertop, about $225
Certified to NSF/ANSI 58 and 53 to reduce arsenic (96%, pentavalent), fluoride (90%), lead (99%), nitrate, nitrite and PFOA/PFOS at the kitchen tap, with a remineralizer.
For manganese
Iron and manganese oxidizing filter
whole-house, at the point of entry, about $1,800
Air-injection or greensand media; fixes staining at the source.
Free, no obligation
Get on the list for a free in-home water test in Woodbury
No water treatment company serves Woodbury through Well Water Nerd yet. We are signing licensed companies on county by county: they test at your tap for free, walk you through the numbers, and quote treatment only if something needs fixing. Leave your details and you are first in line. Nothing is shared until a company joins for Woodbury, and you get an email naming it first.
Common questions
How deep are wells in Woodbury?
The typical domestic well in Woodbury is 500 feet deep, based on 29 wells reported to the state since 1926. One in ten is deeper than 701 feet.
Is there arsenic in well water in Woodbury?
Arsenic was detected in 38% of 84 public well samples in Woodbury, and 0% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.
How high is radon in well water in Woodbury?
The median radon level across 37 public samples in Woodbury was 1,140 pCi/L, with a high of 13,200 pCi/L. New Hampshire recommends treatment above 2,000 pCi/L.
How often should I test a private well in Woodbury?
Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.
Towns near Woodbury
Closest first. Groundwater does not stop at a line on a map, so the next town over is a fair second opinion.
Want the numbers themselves? Download the Connecticut dataset as CSV, every county and town, with the sources named.
Sources
- USGS Water Quality Portal: 1,282 samples in Woodbury. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
- Connecticut DPH and USGS arsenic and uranium survey: 10 samples in Woodbury. Arsenic and uranium in 674 private bedrock wells sampled by the Connecticut Department of Public Health with the U.S. Geological Survey, 2013 to 2015. Retrieved .
- Connecticut well completion reports: 51 well records in Woodbury, 29 domestic. Well completion reports filed online with the Connecticut Department of Consumer Protection since January 2021. Only aggregates are shown; owner names and addresses are never stored. Retrieved September 16, 2026.
- CT DEEP contaminated sites and landfills: 41 regulated sites located in Woodbury. Contaminated or potentially contaminated sites and solid waste landfills from the Connecticut Department of Energy and Environmental Protection. Retrieved September 16, 2026.
Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.