Well Water Nerd

Well water in Pocahontas County, West Virginia

In Pocahontas County, 3% of 76 tested well samples exceeded the EPA limit for nitrate (10 mg/L), based on public data from USGS Water Quality Portal.

The strongest signal is lead: 7% of 27 local samples were above the limit, too few samples to carry the headline but first on the test list below.

452 test results across 14 contaminants from at least 45 wells, 1971 to 2020; nitrate has the most at 76. Data refreshed September 15, 2026.

Compiled by Nick at Well Water Nerd from public records. How these pages are built

An estimated 4,837 people in Pocahontas County get their drinking water from a private well, per USGS 2015 county water use. That is about 56% of residents.

Separately, the USGS national arsenic model estimates that 6% of the 4,837 people on private wells in Pocahontas County draw water above 10 ug/L (the model's range is 3% to 13%), from geology and well depth rather than local tests.

What individual samples found

Each row summarizes every public sample for that contaminant inside Pocahontas County. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.

ContaminantAbove limitSamplesDetectedMedianHighestLimit
Lead
1980 to 2020
2730%03015 ug/L
EPA limit
Nitrate
1971 to 2020
7668%0.1118.110 mg/L
EPA limit
Fluoride
1971 to 2020
5670%0.10.74 mg/L
EPA limit
Copper
1980 to 2020
1947%00.041.3 mg/L
EPA limit
Arsenic
1983 to 2020
1724%0110 ug/L
EPA limit
E. coli
1997 to 2008
120%000 MPN/100mL
EPA limit
Manganese
1971 to 2020
no limit5786%1061,800300 ug/L
health guideline
Chloride
1971 to 2020
no limit56100%1.951250 mg/L
nuisance level
Sodium
1971 to 2020
no limit56100%5.059220 mg/L
health guideline
Iron
1971 to 2020
no limit5587%2205,400300 ug/L
nuisance level
Radon
1997 to 2008
no limit13100%2001,1002,000 pCi/L
health guideline

Sampled fewer than 10 times, too few to summarize: Uranium (4), PFOA (2), PFOS (2).

Over time

Share of samples above the limit by period. A cell needs ten samples to show; a comparison needs twenty in each period. Later periods sample fewer wells, and often the ones already known to have a problem.

Contaminantbefore 20002000s2010s2020s
Nitrate4%50 samples0%22 samplesn/an/a
Fluoride0%43 samples0%11 samplesn/an/a
Lead14%14 samples0%11 samplesn/an/a

Nitrate has held within a few points between the two most recent periods with enough samples.

Closer than the county

See the sampled wells near your address

The same records, drawn around one point: which wells within a few miles were sampled and what they found, how deep the wells next to you were drilled, and any leaking tank or cleanup site within a mile.

Check my address

What this means

The contaminants most often above their limit here are lead (7% of 27 samples) and nitrate (3% of 76 samples). A well next door can differ sharply from yours because bedrock fractures, well depth and plumbing all matter, so these rates describe the area, not your tap.

Manganese, Chloride, and Iron are widespread in local groundwater. They are mainly a staining and taste problem, but high manganese also carries a health advisory for infants.

What to test for in Pocahontas County

  1. 1
    Lead
    7% of 27 local samples were above the limit.
  2. 2
    Nitrate
    3% of 76 local samples were above the limit.
  3. 3
    Coliform bacteria
    Recommended for every private well, every year.
  4. 4
    Radon
    Median local reading is 200 pCi/L.
  5. 5
    Chloride
    Detected in 100% of local samples.
  6. 6
    Iron
    Detected in 87% of local samples.
  7. 7
    Manganese
    Detected in 86% of local samples.

Test your Pocahontas County well for lead, nitrate and coliform bacteria

Certified lab analysis of your own tap water, bottles and prepaid return shipping included. The Essential well panel covers arsenic, uranium, nitrate, lead, copper, manganese, iron, sodium and bacteria; radon and PFAS are add-ons.

Order the Tap Score well water test kit, from $209Already tested? Upload the report

Just want bacteria checked first? Tap Score coliform and E. coli test, $99. Coliform and E. coli are the tests every well needs every year.

Want a quick look before paying for a lab? Home well water test strips on Amazon check hardness, iron, pH and nitrate in minutes. They are a screen, not a result: arsenic, bacteria, uranium and PFAS need a certified lab.

Affiliate links: the merchant pays us a commission and the price is the same for you. It does not change what the data above says. As an Amazon Associate we earn from qualifying purchases.

Where to get a well tested in West Virginia: certified labs, state programs and prices.

Already have results back? Get your lab report read against the Pocahontas County numbers, $29. Every line explained, ranked by what matters, with the fix for each.

The rock under Pocahontas County

Not a principal aquifer

The USGS map places this area outside any principal aquifer, which usually means wells here draw from fractured bedrock or thin local deposits rather than a large regional aquifer. Bedrock wells of that kind are where arsenic, radon and uranium turn up, and yields vary from well to well.

Classification from the USGS Principal Aquifers of the United States (national map, 2003 edition, GIS release 2015), read at the county centroid. A single well can sit in a different unit, especially near a boundary.

Official help in West Virginia

Two places to start that are not selling anything: the state program that answers private well questions, and its list of labs certified to run drinking water tests. A certified lab is the difference between a result you can act on and a number.

Treatment that fits the local profile

Lead

Point-of-use reverse osmosis; Certified lead-removal carbon filter; Neutralizing filter to raise pH and stop leaching

Nitrate

Point-of-use reverse osmosis; Anion exchange; Distillation

Iron

Oxidizing filter whole-house; Water softener (low levels); Aeration plus filtration

Manganese

Oxidizing filter (greensand, birm) whole-house; Water softener (low levels); Point-of-use reverse osmosis

Systems we would look at first

Some links below are affiliate links. If you buy through one, the merchant pays us a commission at no extra cost to you. It does not change which products we list or what the data says.

For lead

Under-sink reverse osmosis system

under-sink or countertop, about $300

Look for NSF/ANSI 58 certification listing the contaminant you need removed.

For lead

Acid neutralizing filter

whole-house, at the point of entry, about $1,200

Raises pH so plumbing stops leaching lead and copper.

For lead

Aquasana SmartFlow reverse osmosis

under-sink or countertop, about $225

Certified to NSF/ANSI 58 and 53 to reduce arsenic (96%, pentavalent), fluoride (90%), lead (99%), nitrate, nitrite and PFOA/PFOS at the kitchen tap, with a remineralizer.

For manganese

Iron and manganese oxidizing filter

whole-house, at the point of entry, about $1,800

Air-injection or greensand media; fixes staining at the source.

Free, no obligation

Get on the list for a free in-home water test in Pocahontas County

No water treatment company serves Pocahontas County through Well Water Nerd yet. We are signing licensed companies on county by county: they test at your tap for free, walk you through the numbers, and quote treatment only if something needs fixing. Leave your details and you are first in line. Nothing is shared until a company joins for Pocahontas County, and you get an email naming it first.

What are you worried about?

The test is free and there is no obligation. No company is named yet; your details stay with us until one joins for your area, and we log the time and address of this request.

Common questions

Is there arsenic in well water in Pocahontas County?

Arsenic was detected in 24% of 17 public well samples in Pocahontas County, and 0% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.

How high is radon in well water in Pocahontas County?

The median radon level across 13 public samples in Pocahontas County was 200 pCi/L, with a high of 1,100 pCi/L. New Hampshire recommends treatment above 2,000 pCi/L.

How often should I test a private well in Pocahontas County?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Counties near Pocahontas County

Closest first. Groundwater does not stop at a line on a map, so the next county over is a fair second opinion.

Want the numbers themselves? Download the West Virginia dataset as CSV, every county and town, with the sources named.

Sources

  • USGS Water Quality Portal: 452 samples in Pocahontas County. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
  • USGS national arsenic model (Ayotte 2017): estimated share of 4,837 people on private wells in Pocahontas County above 10 ug/L of arsenic, from geology, well depth and land use. County estimates of domestic well users with arsenic above 10 ug/L from the USGS national logistic regression model (Ayotte, Medalie and Qi, 2017), with private well population from the USGS 2015 county water-use compilation (Dieter and others, 2018). Retrieved September 15, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.