Well Water Nerd

Well water in Prince William County, Virginia

In Prince William County, <1% of 133 tested well samples exceeded the EPA limit for nitrate (10 mg/L), based on public data from USGS Water Quality Portal.

1,224 test results across 13 contaminants from at least 113 wells, 1968 to 2025; fluoride has the most at 141. Data refreshed September 15, 2026.

Compiled by Nick at Well Water Nerd from public records. How these pages are built

An estimated 99,082 people in Prince William County get their drinking water from a private well, per USGS 2015 county water use. That is about 22% of residents.

Separately, the USGS national arsenic model estimates that <1% of the 99,082 people on private wells in Prince William County draw water above 10 ug/L, from geology and well depth rather than local tests.

What individual samples found

Each row summarizes every public sample for that contaminant inside Prince William County. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.

ContaminantAbove limitSamplesDetectedMedianHighestLimit
Nitrate
1975 to 2025
13373%0.321910 mg/L
EPA limit
Fluoride
1968 to 2025
14162%0.080.94 mg/L
EPA limit
Lead
1990 to 2025
10910%01015 ug/L
EPA limit
Copper
1990 to 2025
10919%00.251.3 mg/L
EPA limit
Arsenic
1975 to 2025
6338%0510 ug/L
EPA limit
Uranium
1994 to 2025
3370%0.042930 ug/L
EPA limit
Chloride
1968 to 2025
no limit141100%6.32370250 mg/L
nuisance level
Sodium
1968 to 2025
no limit141100%9.98620 mg/L
health guideline
Iron
1968 to 2025
no limit14191%1032,800300 ug/L
nuisance level
Manganese
1990 to 2025
no limit11877%6.432,010300 ug/L
health guideline
Radon
1990 to 2014
no limit8998%1,4006,2002,000 pCi/L
health guideline

Sampled fewer than 10 times, too few to summarize: Radium (226 + 228) (4), E. coli (2).

Over time

Share of samples above the limit by period. A cell needs ten samples to show; a comparison needs twenty in each period. Later periods sample fewer wells, and often the ones already known to have a problem.

Contaminantbefore 20002000s2010s2020s
Fluoride0%110 samples0%17 samplesn/an/a
Nitrate<1%102 samples0%17 samplesn/an/a
Lead0%82 samples0%13 samplesn/an/a
Copper0%82 samples0%13 samplesn/an/a
Arsenic0%36 samples0%13 samplesn/an/a

Closer than the county

See the sampled wells near your address

The same records, drawn around one point: which wells within a few miles were sampled and what they found, how deep the wells next to you were drilled, and any leaking tank or cleanup site within a mile.

Check my address

What this means

The contaminants most often above their limit here are nitrate (<1% of 133 samples). A well next door can differ sharply from yours because bedrock fractures, well depth and plumbing all matter, so these rates describe the area, not your tap.

Chloride, Iron, and Manganese are widespread in local groundwater. They are mainly a staining and taste problem, but high manganese also carries a health advisory for infants.

What to test for in Prince William County

  1. 1
    Nitrate
    <1% of 133 local samples were above the limit.
  2. 2
    Coliform bacteria
    Recommended for every private well, every year.
  3. 3
    Radon
    Median local reading is 1,400 pCi/L.
  4. 4
    Chloride
    Detected in 100% of local samples.
  5. 5
    Iron
    Detected in 91% of local samples.
  6. 6
    Manganese
    Detected in 77% of local samples.
  7. 7
    Fluoride
    Detected in 62% of local samples.
  8. 8
    Volatile organic compounds (VOCs)
    1,241 leaking underground storage tank sites on record locally.

Test your Prince William County well for nitrate, coliform bacteria and radon

Certified lab analysis of your own tap water, bottles and prepaid return shipping included. The Essential well panel covers arsenic, uranium, nitrate, lead, copper, manganese, iron, sodium and bacteria; radon and PFAS are add-ons.

Order the Tap Score well water test kit, from $209Already tested? Upload the report

Just want bacteria checked first? Tap Score coliform and E. coli test, $99. Coliform and E. coli are the tests every well needs every year.

Want a quick look before paying for a lab? Home well water test strips on Amazon check hardness, iron, pH and nitrate in minutes. They are a screen, not a result: arsenic, bacteria, uranium and PFAS need a certified lab.

Affiliate links: the merchant pays us a commission and the price is the same for you. It does not change what the data above says. As an Amazon Associate we earn from qualifying purchases.

Where to get a well tested in Virginia: certified labs, state programs and prices.

Already have results back? Get your lab report read against the Prince William County numbers, $29. Every line explained, ranked by what matters, with the fix for each.

The rock under Prince William County

Piedmont and Blue Ridge crystalline-rock aquifers

Igneous and metamorphic-rock. Granite and similar crystalline rock hold water only in fractures. Wells are deep and yields modest, and the rock itself is the source of arsenic, radon and uranium, which is why those three head the test list in bedrock country.

Classification from the USGS Principal Aquifers of the United States (national map, 2003 edition, GIS release 2015), read at the county centroid. A single well can sit in a different unit, especially near a boundary.

Official help in Virginia

Two places to start that are not selling anything: the state program that answers private well questions, and its list of labs certified to run drinking water tests. A certified lab is the difference between a result you can act on and a number.

Contamination sources on record in Prince William County

Virginia DEQ records 1,241 leaking underground storage tank sites and 25 reported spills and releases in Prince William County, among 1,301 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.

1,241
leaking underground storage tank sitesGasoline and heating oil that leaked from tanks move through groundwater as benzene, MTBE and other volatile organic compounds.
25
reported spills and releasesMost spills are fuel; a few are solvents or chemicals that reach the water table.
14
lined landfills and transfer facilities
21
other solid waste facilities

Treatment that fits the local profile

Nitrate

Point-of-use reverse osmosis; Anion exchange; Distillation

Iron

Oxidizing filter whole-house; Water softener (low levels); Aeration plus filtration

Manganese

Oxidizing filter (greensand, birm) whole-house; Water softener (low levels); Point-of-use reverse osmosis

Systems we would look at first

Some links below are affiliate links. If you buy through one, the merchant pays us a commission at no extra cost to you. It does not change which products we list or what the data says.

For nitrate

Under-sink reverse osmosis system

under-sink or countertop, about $300

Look for NSF/ANSI 58 certification listing the contaminant you need removed.

For nitrate

Aquasana SmartFlow reverse osmosis

under-sink or countertop, about $225

Certified to NSF/ANSI 58 and 53 to reduce arsenic (96%, pentavalent), fluoride (90%), lead (99%), nitrate, nitrite and PFOA/PFOS at the kitchen tap, with a remineralizer.

For iron

Iron and manganese oxidizing filter

whole-house, at the point of entry, about $1,800

Air-injection or greensand media; fixes staining at the source.

Free, no obligation

Get on the list for a free in-home water test in Prince William County

No water treatment company serves Prince William County through Well Water Nerd yet. We are signing licensed companies on county by county: they test at your tap for free, walk you through the numbers, and quote treatment only if something needs fixing. Leave your details and you are first in line. Nothing is shared until a company joins for Prince William County, and you get an email naming it first.

What are you worried about?

The test is free and there is no obligation. No company is named yet; your details stay with us until one joins for your area, and we log the time and address of this request.

Common questions

Is there arsenic in well water in Prince William County?

Arsenic was detected in 38% of 63 public well samples in Prince William County, and 0% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.

How high is radon in well water in Prince William County?

The median radon level across 89 public samples in Prince William County was 1,400 pCi/L, with a high of 6,200 pCi/L. New Hampshire recommends treatment above 2,000 pCi/L.

How often should I test a private well in Prince William County?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Counties near Prince William County

Closest first. Groundwater does not stop at a line on a map, so the next county over is a fair second opinion.

Want the numbers themselves? Download the Virginia dataset as CSV, every county and town, with the sources named.

Sources

  • USGS Water Quality Portal: 1,224 samples in Prince William County. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
  • USGS national arsenic model (Ayotte 2017): estimated share of 99,082 people on private wells in Prince William County above 10 ug/L of arsenic, from geology, well depth and land use. County estimates of domestic well users with arsenic above 10 ug/L from the USGS national logistic regression model (Ayotte, Medalie and Qi, 2017), with private well population from the USGS 2015 county water-use compilation (Dieter and others, 2018). Retrieved September 15, 2026.
  • Virginia DEQ regulated sites: 1,301 regulated sites located in Prince William County. Petroleum releases and solid waste permits from the Virginia Department of Environmental Quality Environmental Data Mapper. Retrieved September 17, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.