In Dover, 4% of 54 private wells tested had uranium above the Vermont limit (20 ug/L), according to the Vermont Department of Health.

72 private wells tested in state summaries. Data refreshed .

What homeowner tests found

Vermont Tracking private well summaries: private wells tested and reported to the state. Shares are against the level the state applies to each contaminant, named in the last column; several are stricter than EPA.

ContaminantWells testedAbove state levelMedian95th pctHighestState level
Gross alpha
Gross Alpha
388%1.63435.415 pCi/L
Uranium544%*106120 ug/L
Fluoride720%0.050.3051.34 mg/L
Arsenic570%**110 ug/L
Nitrate330%0.250.472.210 mg/L

* suppressed by the publisher because too few wells were tested.

Get the free Dover well report

One email with the numbers above, what they mean for a home in Dover, exactly which tests to order, and what treatment fits the local profile. No spam, unsubscribe in one click.

What this means

Among homeowners in Dover who sent a sample to the state lab, the health-based limits most often exceeded were uranium (4% of 54 wells). These are ordinary wells tested by their owners, so the shares are the best available picture of a typical well here, with one caveat: people test more often when they suspect a problem.

What to test for in Dover

  • Volatile organic compounds (VOCs)21 leaking underground storage tank sites on record locally.
  • PFAS1 unlined landfill on record locally.
  • Metals panel4 hazardous waste sites on record locally.
  • Gross alpha8% of 38 local wells tested were above the Vermont limit.
  • Uranium4% of 54 local wells tested were above the Vermont limit.
  • Coliform bacteriaRecommended for every private well, every year.
  • NitrateRecommended for every private well, especially near farms or septic systems.

Wells in Dover

697 domestic wells in Dover are on record with the state since 1988. 100% are drilled into bedrock, and the typical well is 380 feet deep (one in ten goes past 596 feet).

In a typical Dover well, bedrock starts about 13 feet down, the median yield is 5 gallons per minute, 36% of wells yield under 3 gallons per minute and usually need a storage tank.

Bedrock wells are where arsenic, uranium and radon come from: the water sits in fractures in granite and metamorphic rock and picks up whatever the rock carries. That is why testing for those three matters more here than in a dug or gravel well.

96
1980s
173
1990s
282
2000s
74
2010s
65
2020s

Contamination sources on record in Dover

Vermont ANR records 21 leaking underground storage tank sites, 1 unlined landfill, and 4 hazardous waste sites in Dover, among 36 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.

21
leaking underground storage tank sitesGasoline and heating oil that leaked from tanks move through groundwater as benzene, MTBE and other volatile organic compounds.
1
unlined landfillOlder unlined landfills are a leading source of PFAS, VOCs and metals in nearby wells.
4
hazardous waste sitesSolvents, degreasers and metals from industrial sites can travel far in fractured bedrock.
10
registered underground storage tank sitesRegistered tanks are regulated and inspected; they matter most when they are old or near a shallow well.

Treatment that fits the local profile

Gross alpha
Point-of-use reverse osmosis; Water softener (cation exchange) for radium; Anion exchange for uranium

Book a free water test in Dover

A licensed local water treatment company tests your tap water in your home, walks you through the numbers, and quotes treatment only if something needs fixing. Free, about 30 minutes, no obligation.

What are you worried about?

The test is free and there is no obligation. Your details go only to the company named above, and we log the time and address of this request.

Common questions

How deep are wells in Dover?

The typical domestic well in Dover is 380 feet deep, based on 697 wells reported to the state since 1988. One in ten is deeper than 596 feet. 100% are drilled into bedrock.

How often should I test a private well in Dover?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Sources

  • Vermont Tracking private well summaries: summaries for 5 contaminants in Dover, up to 72 wells each. Town summaries of private well tests reported to the Vermont Department of Health, published through Vermont Environmental Public Health Tracking. Shares are against the limit Vermont applies to each analyte: arsenic 10 ug/L, uranium 20 ug/L (stricter than EPA), fluoride 4 mg/L, nitrate 10 mg/L, gross alpha 15 pCi/L, radon 4,000 pCi/L advisory. Only towns with 20 or more results are published; statistics below the reporting limit show as *. Retrieved September 3, 2026.
  • Vermont ANR well completion reports: 747 well records in Dover, 697 domestic. Well completion reports filed with the Vermont Agency of Natural Resources since 1966. Only aggregates are shown; owner names and addresses are never stored. Retrieved September 3, 2026.
  • Vermont ANR regulated sites: 36 regulated sites located in Dover. Hazardous waste sites, landfills and underground storage tanks from the Vermont Agency of Natural Resources. Retrieved September 3, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.