Well Water Nerd

Well water in Waltham, Vermont

In Waltham, 3% of 30 private wells tested had uranium above the Vermont limit (20 ug/L), according to the Vermont Department of Health.

35 private wells tested in state summaries. Data refreshed .

What homeowner tests found

Vermont Tracking private well summaries: private wells tested and reported to the state. Shares are against the level the state applies to each contaminant, named in the last column; several are stricter than EPA.

ContaminantWells testedAbove state levelMedian95th pctHighestState level
Gross alpha
Gross Alpha
225%1.98.924.115 pCi/L
Fluoride284%0.120.4966.64 mg/L
Uranium303%163720 ug/L
Nitrate350%0.251.867.910 mg/L
Arsenic310%*5910 ug/L

* suppressed by the publisher because too few wells were tested.

Get the free Waltham well report

One email with the numbers above, what they mean for a home in Waltham, exactly which tests to order, and what treatment fits the local profile. No spam, unsubscribe in one click.

What this means

Among homeowners in Waltham who sent a sample to the state lab, the health-based limits most often exceeded were fluoride (4% of 28 wells) and uranium (3% of 30 wells). These are ordinary wells tested by their owners, so the shares are the best available picture of a typical well here, with one caveat: people test more often when they suspect a problem.

What to test for in Waltham

  • Volatile organic compounds (VOCs)1 leaking underground storage tank site on record locally.
  • Gross alpha5% of 22 local wells tested were above the Vermont limit.
  • Fluoride4% of 28 local wells tested were above the Vermont limit.
  • Uranium3% of 30 local wells tested were above the Vermont limit.
  • Coliform bacteriaRecommended for every private well, every year.
  • NitrateRecommended for every private well, especially near farms or septic systems.

Wells in Waltham

38 domestic wells in Waltham are on record with the state since 1996. 97% are drilled into bedrock, and the typical well is 280 feet deep (one in ten goes past 633 feet).

In a typical Waltham well, bedrock starts about 26 feet down, the median yield is 10 gallons per minute, 18% of wells yield under 3 gallons per minute and usually need a storage tank.

Bedrock wells are where arsenic, uranium and radon come from: the water sits in fractures in granite and metamorphic rock and picks up whatever the rock carries. That is why testing for those three matters more here than in a dug or gravel well.

12
1990s
9
2000s
9
2010s
8
2020s

Contamination sources on record in Waltham

Vermont ANR records 1 leaking underground storage tank site in Waltham, among 1 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.

1
leaking underground storage tank siteGasoline and heating oil that leaked from tanks move through groundwater as benzene, MTBE and other volatile organic compounds.

Book a free water test in Waltham

A licensed local water treatment company tests your tap water in your home, walks you through the numbers, and quotes treatment only if something needs fixing. Free, about 30 minutes, no obligation.

What are you worried about?

The test is free and there is no obligation. Your details go only to the company named above, and we log the time and address of this request.

Common questions

How deep are wells in Waltham?

The typical domestic well in Waltham is 280 feet deep, based on 38 wells reported to the state since 1996. One in ten is deeper than 633 feet. 97% are drilled into bedrock.

How often should I test a private well in Waltham?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Sources

  • Vermont Tracking private well summaries: summaries for 5 contaminants in Waltham, up to 35 wells each. Town summaries of private well tests reported to the Vermont Department of Health, published through Vermont Environmental Public Health Tracking. Shares are against the limit Vermont applies to each analyte: arsenic 10 ug/L, uranium 20 ug/L (stricter than EPA), fluoride 4 mg/L, nitrate 10 mg/L, gross alpha 15 pCi/L, radon 4,000 pCi/L advisory. Only towns with 20 or more results are published; statistics below the reporting limit show as *. Retrieved September 3, 2026.
  • Vermont ANR well completion reports: 40 well records in Waltham, 38 domestic. Well completion reports filed with the Vermont Agency of Natural Resources since 1966. Only aggregates are shown; owner names and addresses are never stored. Retrieved September 3, 2026.
  • Vermont ANR regulated sites: 1 regulated sites located in Waltham. Hazardous waste sites, landfills and underground storage tanks from the Vermont Agency of Natural Resources. Retrieved September 3, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.