Well water in Starksboro, Vermont
In Starksboro, 3% of 141 private wells tested had arsenic above the Vermont limit (10 ug/L), according to the Vermont Department of Health.
164 private wells tested in state summaries. Data refreshed .
What homeowner tests found
Vermont Tracking private well summaries: private wells tested and reported to the state. Shares are against the level the state applies to each contaminant, named in the last column; several are stricter than EPA.
| Contaminant | Wells tested | Above state level | Median | 95th pct | Highest | State level | |
|---|---|---|---|---|---|---|---|
| Gross alpha Gross Alpha | 94 | 6% | 1.6 | 17.7 | 23.9 | 15 pCi/L | |
| Arsenic | 141 | 3% | * | 4 | 72 | 10 ug/L | |
| Nitrate | 164 | 0% | 0.25 | 1.87 | 9.4 | 10 mg/L | |
| Fluoride | 151 | 0% | 0.13 | 0.36 | 3.2 | 4 mg/L | |
| Uranium | 133 | 0% | * | 7 | 29 | 20 ug/L |
* suppressed by the publisher because too few wells were tested.
Get the free Starksboro well report
One email with the numbers above, what they mean for a home in Starksboro, exactly which tests to order, and what treatment fits the local profile. No spam, unsubscribe in one click.
What this means
Among homeowners in Starksboro who sent a sample to the state lab, the health-based limits most often exceeded were arsenic (3% of 141 wells). These are ordinary wells tested by their owners, so the shares are the best available picture of a typical well here, with one caveat: people test more often when they suspect a problem.
What to test for in Starksboro
- Volatile organic compounds (VOCs)7 leaking underground storage tank sites on record locally.
- PFAS1 unlined landfill on record locally.
- Gross alpha6% of 94 local wells tested were above the Vermont limit.
- Arsenic3% of 141 local wells tested were above the Vermont limit.
- Coliform bacteriaRecommended for every private well, every year.
- NitrateRecommended for every private well, especially near farms or septic systems.
Wells in Starksboro
228 domestic wells in Starksboro are on record with the state since 1996. 98% are drilled into bedrock, and the typical well is 350 feet deep (one in ten goes past 622 feet).
In a typical Starksboro well, bedrock starts about 26 feet down, the median yield is 10 gallons per minute, 23% of wells yield under 3 gallons per minute and usually need a storage tank.
Bedrock wells are where arsenic, uranium and radon come from: the water sits in fractures in granite and metamorphic rock and picks up whatever the rock carries. That is why testing for those three matters more here than in a dug or gravel well.
Contamination sources on record in Starksboro
Vermont ANR records 7 leaking underground storage tank sites and 1 unlined landfill in Starksboro, among 10 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.
- 7
- leaking underground storage tank sitesGasoline and heating oil that leaked from tanks move through groundwater as benzene, MTBE and other volatile organic compounds.
- 1
- unlined landfillOlder unlined landfills are a leading source of PFAS, VOCs and metals in nearby wells.
- 2
- registered underground storage tank sitesRegistered tanks are regulated and inspected; they matter most when they are old or near a shallow well.
Treatment that fits the local profile
- Gross alpha
- Point-of-use reverse osmosis; Water softener (cation exchange) for radium; Anion exchange for uranium
Book a free water test in Starksboro
A licensed local water treatment company tests your tap water in your home, walks you through the numbers, and quotes treatment only if something needs fixing. Free, about 30 minutes, no obligation.
Common questions
How deep are wells in Starksboro?
The typical domestic well in Starksboro is 350 feet deep, based on 228 wells reported to the state since 1996. One in ten is deeper than 622 feet. 98% are drilled into bedrock.
How often should I test a private well in Starksboro?
Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.
Sources
- Vermont Tracking private well summaries: summaries for 5 contaminants in Starksboro, up to 164 wells each. Town summaries of private well tests reported to the Vermont Department of Health, published through Vermont Environmental Public Health Tracking. Shares are against the limit Vermont applies to each analyte: arsenic 10 ug/L, uranium 20 ug/L (stricter than EPA), fluoride 4 mg/L, nitrate 10 mg/L, gross alpha 15 pCi/L, radon 4,000 pCi/L advisory. Only towns with 20 or more results are published; statistics below the reporting limit show as *. Retrieved September 3, 2026.
- Vermont ANR well completion reports: 236 well records in Starksboro, 228 domestic. Well completion reports filed with the Vermont Agency of Natural Resources since 1966. Only aggregates are shown; owner names and addresses are never stored. Retrieved September 3, 2026.
- Vermont ANR regulated sites: 10 regulated sites located in Starksboro. Hazardous waste sites, landfills and underground storage tanks from the Vermont Agency of Natural Resources. Retrieved September 3, 2026.
Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.