Well Water Nerd

Well water in Millard County, Utah

1in3

Testing strongly recommended

tested well samples in Millard County exceeded the EPA limit for arsenic (10 ug/L), based on public data from USGS Water Quality Portal.

6,716 test results across 13 contaminants from at least 341 wells, 1923 to 2021; chloride has the most at 1,257. Data refreshed September 15, 2026.

Compiled by Nick at Well Water Nerd from public records. How these pages are built

An estimated 3,562 people in Millard County get their drinking water from a private well, per USGS 2015 county water use. That is about 28% of residents.

Separately, the USGS national arsenic model estimates that 8% of the 3,562 people on private wells in Millard County draw water above 10 ug/L (the model's range is 6% to 10%), from geology and well depth rather than local tests.

What individual samples found

Each row summarizes every public sample for that contaminant inside Millard County. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.

ContaminantAbove limitSamplesDetectedMedianHighestLimit
Arsenic
1968 to 2021
52592%590410 ug/L
EPA limit
Lead
1968 to 2021
22128%071115 ug/L
EPA limit
Nitrate
1923 to 2021
95196%1.36610 mg/L
EPA limit
Copper
1968 to 2019
19723%01661.3 mg/L
EPA limit
Fluoride
1941 to 2021
79097%0.335.64 mg/L
EPA limit
Uranium
2005 to 2021
192100%2.4218.530 ug/L
EPA limit
Radium (226 + 228)
1995 to 2013
2425%01.175 pCi/L
EPA limit
Chloride
1941 to 2021
no limit1,257100%16065,000250 mg/L
nuisance level
Sodium
1942 to 2021
no limit997100%110418,00020 mg/L
health guideline
Iron
1941 to 2021
no limit79859%5252,000300 ug/L
nuisance level
Manganese
1952 to 2021
no limit76252%098,900300 ug/L
health guideline

Sampled fewer than 10 times, too few to summarize: E. coli (1), Radon (1).

Over time

Share of samples above the limit by period. A cell needs ten samples to show; a comparison needs twenty in each period. Later periods sample fewer wells, and often the ones already known to have a problem.

Contaminantbefore 20002000s2010s2020s
Nitrate7%745 samples9%64 samples7%126 samples6%16 samples
Fluoride<1%578 samples0%69 samples0%127 samples0%16 samples
Arsenic35%179 samples44%144 samples28%186 samples6%16 samples
Lead26%61 samples1%95 samples2%55 samples0%10 samples
Copper7%45 samples0%95 samples0%57 samplesn/a
Uraniumn/a0%49 samples0%127 samples0%16 samples

Arsenic above the limit in Millard County fell from 44% of 144 samples in the 2000s to 28% of 186 in the 2010s.

Nitrate, fluoride, lead, copper, uranium have held within a few points between the two most recent periods with enough samples.

Closer than the county

See the sampled wells near your address

The same records, drawn around one point: which wells within a few miles were sampled and what they found, how deep the wells next to you were drilled, and any leaking tank or cleanup site within a mile.

Check my address

What this means

The contaminants most often above their limit here are arsenic (34% of 525 samples), lead (8% of 221 samples), and nitrate (7% of 951 samples). A well next door can differ sharply from yours because bedrock fractures, well depth and plumbing all matter, so these rates describe the area, not your tap.

Chloride, Iron, and Manganese are widespread in local groundwater. They are mainly a staining and taste problem, but high manganese also carries a health advisory for infants.

What to test for in Millard County

  1. 1
    Arsenic
    34% of 525 local samples were above the limit.
  2. 2
    Lead
    8% of 221 local samples were above the limit.
  3. 3
    Nitrate
    7% of 951 local samples were above the limit.
  4. 4
    Copper
    2% of 197 local samples were above the limit.
  5. 5
    Fluoride
    <1% of 790 local samples were above the limit.
  6. 6
    Coliform bacteria
    Recommended for every private well, every year.
  7. 7
    Radon
    Median local reading is 300 pCi/L.
  8. 8
    Volatile organic compounds (VOCs)
    59 leaking underground storage tank sites on record locally.
  9. 9
    Metals panel
    2 hazardous waste sites on record locally.

Test your Millard County well for arsenic, lead and nitrate

Certified lab analysis of your own tap water, bottles and prepaid return shipping included. The Essential well panel covers arsenic, uranium, nitrate, lead, copper, manganese, iron, sodium and bacteria; radon and PFAS are add-ons.

Order the Tap Score well water test kit, from $209Already tested? Upload the report

Just want bacteria checked first? Tap Score coliform and E. coli test, $99. Coliform and E. coli are the tests every well needs every year.

Want a quick look before paying for a lab? Home well water test strips on Amazon check hardness, iron, pH and nitrate in minutes. They are a screen, not a result: arsenic, bacteria, uranium and PFAS need a certified lab.

Affiliate links: the merchant pays us a commission and the price is the same for you. It does not change what the data above says. As an Amazon Associate we earn from qualifying purchases.

Where to get a well tested in Utah: certified labs, state programs and prices.

Already have results back? Get your lab report read against the Millard County numbers, $29. Every line explained, ranked by what matters, with the fix for each.

The rock under Millard County

Not a principal aquifer

The USGS map places this area outside any principal aquifer, which usually means wells here draw from fractured bedrock or thin local deposits rather than a large regional aquifer. Bedrock wells of that kind are where arsenic, radon and uranium turn up, and yields vary from well to well.

Classification from the USGS Principal Aquifers of the United States (national map, 2003 edition, GIS release 2015), read at the county centroid. A single well can sit in a different unit, especially near a boundary.

Official help in Utah

Two places to start that are not selling anything: the state program that answers private well questions, and its list of labs certified to run drinking water tests. A certified lab is the difference between a result you can act on and a number.

Contamination sources on record in Millard County

Utah DEQ records 59 leaking underground storage tank sites and 2 hazardous waste sites in Millard County, among 126 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.

59
leaking underground storage tank sitesGasoline and heating oil that leaked from tanks move through groundwater as benzene, MTBE and other volatile organic compounds.
2
hazardous waste sitesSolvents, degreasers and metals from industrial sites can travel far in fractured bedrock.
65
registered underground storage tank sitesRegistered tanks are regulated and inspected; they matter most when they are old or near a shallow well.

Treatment that fits the local profile

Arsenic

Point-of-use reverse osmosis; Adsorptive media (iron-based) whole-house; Anion exchange

Lead

Point-of-use reverse osmosis; Certified lead-removal carbon filter; Neutralizing filter to raise pH and stop leaching

Nitrate

Point-of-use reverse osmosis; Anion exchange; Distillation

Copper

Neutralizing filter to raise pH; Point-of-use reverse osmosis

Fluoride

Point-of-use reverse osmosis; Activated alumina; Distillation

Systems we would look at first

Some links below are affiliate links. If you buy through one, the merchant pays us a commission at no extra cost to you. It does not change which products we list or what the data says.

For arsenic

Under-sink reverse osmosis system

under-sink or countertop, about $300

Look for NSF/ANSI 58 certification listing the contaminant you need removed.

For arsenic

Whole-house arsenic and uranium filter

whole-house, at the point of entry, about $2,500

Adsorptive iron-based media; sized to your well yield.

For arsenic

Aquasana SmartFlow reverse osmosis

under-sink or countertop, about $225

Certified to NSF/ANSI 58 and 53 to reduce arsenic (96%, pentavalent), fluoride (90%), lead (99%), nitrate, nitrite and PFOA/PFOS at the kitchen tap, with a remineralizer.

For lead

Aquasana Claryum 3-Stage under-sink filter

under-sink or countertop, about $175

Certified to NSF/ANSI 53 to reduce 99% of lead and 99.7% of PFOA and PFOS at the tap. Not a fix for arsenic, nitrate or bacteria.

For lead

Acid neutralizing filter

whole-house, at the point of entry, about $1,200

Raises pH so plumbing stops leaching lead and copper.

Free, no obligation

Get on the list for a free in-home water test in Millard County

No water treatment company serves Millard County through Well Water Nerd yet. We are signing licensed companies on county by county: they test at your tap for free, walk you through the numbers, and quote treatment only if something needs fixing. Leave your details and you are first in line. Nothing is shared until a company joins for Millard County, and you get an email naming it first.

What are you worried about?

The test is free and there is no obligation. No company is named yet; your details stay with us until one joins for your area, and we log the time and address of this request.

Common questions

Is there arsenic in well water in Millard County?

Arsenic was detected in 92% of 525 public well samples in Millard County, and 34% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.

How often should I test a private well in Millard County?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Counties near Millard County

Closest first. Groundwater does not stop at a line on a map, so the next county over is a fair second opinion.

Want the numbers themselves? Download the Utah dataset as CSV, every county and town, with the sources named.

Sources

  • USGS Water Quality Portal: 6,716 samples in Millard County. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
  • USGS national arsenic model (Ayotte 2017): estimated share of 3,562 people on private wells in Millard County above 10 ug/L of arsenic, from geology, well depth and land use. County estimates of domestic well users with arsenic above 10 ug/L from the USGS national logistic regression model (Ayotte, Medalie and Qi, 2017), with private well population from the USGS 2015 county water-use compilation (Dieter and others, 2018). Retrieved September 15, 2026.
  • Utah DEQ regulated sites: 126 regulated sites located in Millard County. Underground storage tank facilities, CERCLA site assessments and National Priorities List sites from the Utah Department of Environmental Quality. Retrieved September 18, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.