Well Water Nerd

Well water in Red River County, Texas

In Red River County, 2% of 50 tested well samples exceeded the EPA limit for fluoride (4 mg/L), based on public data from Texas Water Development Board Groundwater Database.

50 individual samples from 36 wells, 1971 to 2023. Data refreshed September 9, 2026.

TWDB samples an ambient monitoring network of wells on a rotation, so these describe aquifers, not a survey of homeowners' tests.

What individual samples found

Each row summarizes every public sample for that contaminant inside Red River County. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.

ContaminantSamplesDetectedAbove limitMedianHighestLimit
Nitrate
1997 to 2023
1443%7%011.310 mg/L
EPA limit
Fluoride
1971 to 2023
5076%2%0.34.34 mg/L
EPA limit
Copper
1997 to 2023
1457%0%0.0020.0211.3 mg/L
EPA limit
Arsenic
1997 to 2023
147%0%0710 ug/L
EPA limit
Lead
1997 to 2023
1414%0%0215 ug/L
EPA limit
Chloride
1971 to 2023
50100%no limit601,330250 mg/L
nuisance level
Sodium
1971 to 2023
49100%no limit1911,43420 mg/L
health guideline
Iron
1978 to 2023
1631%no limit0426300 ug/L
nuisance level
Manganese
1997 to 2023
1486%no limit4.8925300 ug/L
health guideline

Sampled fewer than 10 times, too few to summarize: Uranium (3).

Get the free Red River County well report

One email with the numbers above, what they mean for a home in Red River County, exactly which tests to order, and what treatment fits the local profile. No spam, unsubscribe in one click.

What this means

The contaminants most often above their limit here are nitrate (7% of 14 samples) and fluoride (2% of 50 samples). A well next door can differ sharply from yours because bedrock fractures, well depth and plumbing all matter, so these rates describe the area, not your tap.

Chloride and Manganese are widespread in local groundwater. They are mainly a staining and taste problem, but high manganese also carries a health advisory for infants.

What to test for in Red River County

  • Volatile organic compounds (VOCs)24 leaking underground storage tank sites on record locally.
  • Nitrate7% of 14 local samples were above the limit.
  • Fluoride2% of 50 local samples were above the limit.
  • Coliform bacteriaRecommended for every private well, every year.
  • ChlorideDetected in 100% of local samples.
  • ManganeseDetected in 86% of local samples.
  • CopperDetected in 57% of local samples.

Contamination sources on record in Red River County

TCEQ records 24 leaking underground storage tank sites in Red River County, among 29 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.

24
leaking underground storage tank sitesGasoline and heating oil that leaked from tanks move through groundwater as benzene, MTBE and other volatile organic compounds.
5
lined landfills and transfer facilities

Treatment that fits the local profile

Nitrate
Point-of-use reverse osmosis; Anion exchange; Distillation
Fluoride
Point-of-use reverse osmosis; Activated alumina; Distillation
Copper
Neutralizing filter to raise pH; Point-of-use reverse osmosis
Chloride
Point-of-use reverse osmosis; Distillation
Manganese
Oxidizing filter (greensand, birm) whole-house; Water softener (low levels); Point-of-use reverse osmosis

Get your Red River County water tested at home

A licensed local water treatment company tests your tap water in your home, walks you through the numbers, and quotes treatment only if something needs fixing. Free, about 30 minutes, no obligation. Tell us what you need and we match you with a company that serves Red River County.

What are you worried about?

The test is free and there is no obligation. Your details go only to the company named above, and we log the time and address of this request.

Common questions

Is there arsenic in well water in Red River County?

Arsenic was detected in 7% of 14 public well samples in Red River County, and 0% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.

How often should I test a private well in Red River County?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Sources

  • Texas Water Development Board Groundwater Database: 238 samples in Red River County. Water quality samples from the Texas Water Development Board Groundwater Database, collected by TWDB, groundwater conservation districts and cooperators. Retrieved September 9, 2026.
  • TCEQ regulated sites: 29 regulated sites located in Red River County. Leaking petroleum storage tank sites, state Superfund sites and municipal solid waste landfills from the Texas Commission on Environmental Quality. Retrieved September 9, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.