Well water in Montague County, Texas
In Montague County, 3% of 285 tested well samples exceeded the EPA limit for fluoride (4 mg/L), based on public data from Texas Water Development Board Groundwater Database and USGS Water Quality Portal.
288 individual samples from 245 wells, 1944 to 2023. Data refreshed September 9, 2026.
TWDB samples an ambient monitoring network of wells on a rotation, so these describe aquifers, not a survey of homeowners' tests.
What individual samples found
Each row summarizes every public sample for that contaminant inside Montague County. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.
| Contaminant | Samples | Detected | Above limit | Median | Highest | Limit | |
|---|---|---|---|---|---|---|---|
| Fluoride 1961 to 2023 | 285 | 99% | 3% | 0.6 | 5.8 | 4 mg/L EPA limit | |
| Nitrate 1970 to 2023 | 43 | 65% | 2% | 0.355 | 74 | 10 mg/L EPA limit | |
| Arsenic 1989 to 2023 | 20 | 0% | 0% | 0 | 0 | 10 ug/L EPA limit | |
| Lead 1989 to 2023 | 19 | 5% | 0% | 0 | 1.19 | 15 ug/L EPA limit | |
| Copper 1989 to 2023 | 19 | 63% | 0% | 0.002 | 0.008 | 1.3 mg/L EPA limit | |
| Uranium 1994 to 2023 | 12 | 33% | 0% | 0 | 7 | 30 ug/L EPA limit | |
| Chloride 1944 to 2023 | 288 | 100% | no limit | 66 | 3,632 | 250 mg/L nuisance level | |
| Sodium 1955 to 2023 | 287 | 100% | no limit | 178 | 1,250 | 20 mg/L health guideline | |
| Iron 1957 to 2023 | 27 | 63% | no limit | 36 | 15,000 | 300 ug/L nuisance level | |
| Manganese 1983 to 2023 | 20 | 65% | no limit | 7.75 | 600 | 300 ug/L health guideline |
Sampled fewer than 10 times, too few to summarize: Gross alpha (7), Radium (226 + 228) (4).
Get the free Montague County well report
One email with the numbers above, what they mean for a home in Montague County, exactly which tests to order, and what treatment fits the local profile. No spam, unsubscribe in one click.
What this means
The contaminants most often above their limit here are fluoride (3% of 285 samples) and nitrate (2% of 43 samples). A well next door can differ sharply from yours because bedrock fractures, well depth and plumbing all matter, so these rates describe the area, not your tap.
Chloride, Iron, and Manganese are widespread in local groundwater. They are mainly a staining and taste problem, but high manganese also carries a health advisory for infants.
What to test for in Montague County
- Volatile organic compounds (VOCs)35 leaking underground storage tank sites on record locally.
- Fluoride3% of 285 local samples were above the limit.
- Nitrate2% of 43 local samples were above the limit.
- Coliform bacteriaRecommended for every private well, every year.
- Gross alphaAbove the limit in 1 of 7 local samples; too few to quote a rate.
- ChlorideDetected in 100% of local samples.
- ManganeseDetected in 65% of local samples.
- CopperDetected in 63% of local samples.
Contamination sources on record in Montague County
TCEQ records 35 leaking underground storage tank sites in Montague County, among 52 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.
- 35
- leaking underground storage tank sitesGasoline and heating oil that leaked from tanks move through groundwater as benzene, MTBE and other volatile organic compounds.
- 17
- lined landfills and transfer facilities
Treatment that fits the local profile
- Fluoride
- Point-of-use reverse osmosis; Activated alumina; Distillation
- Nitrate
- Point-of-use reverse osmosis; Anion exchange; Distillation
- Copper
- Neutralizing filter to raise pH; Point-of-use reverse osmosis
- Chloride
- Point-of-use reverse osmosis; Distillation
- Iron
- Oxidizing filter whole-house; Water softener (low levels); Aeration plus filtration
Get your Montague County water tested at home
A licensed local water treatment company tests your tap water in your home, walks you through the numbers, and quotes treatment only if something needs fixing. Free, about 30 minutes, no obligation. Tell us what you need and we match you with a company that serves Montague County.
Common questions
Is there arsenic in well water in Montague County?
Arsenic was detected in 0% of 20 public well samples in Montague County, and 0% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.
How often should I test a private well in Montague County?
Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.
Sources
- Texas Water Development Board Groundwater Database: 1,024 samples in Montague County. Water quality samples from the Texas Water Development Board Groundwater Database, collected by TWDB, groundwater conservation districts and cooperators. Retrieved September 9, 2026.
- USGS Water Quality Portal: 7 samples in Montague County. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
- TCEQ regulated sites: 52 regulated sites located in Montague County. Leaking petroleum storage tank sites, state Superfund sites and municipal solid waste landfills from the Texas Commission on Environmental Quality. Retrieved September 9, 2026.
Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.