Well water in Gaines County, Texas
In Gaines County, 71% of 38 tested well samples exceeded the EPA limit for arsenic (10 ug/L), based on public data from Texas Water Development Board Groundwater Database and USGS Water Quality Portal.
80 individual samples from 36 wells, 1938 to 2016. Data refreshed September 9, 2026.
TWDB samples an ambient monitoring network of wells on a rotation, so these describe aquifers, not a survey of homeowners' tests.
What individual samples found
Each row summarizes every public sample for that contaminant inside Gaines County. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.
| Contaminant | Samples | Detected | Above limit | Median | Highest | Limit | |
|---|---|---|---|---|---|---|---|
| Arsenic 1990 to 2012 | 38 | 97% | 71% | 14 | 34.7 | 10 ug/L EPA limit | |
| Fluoride 1938 to 2012 | 78 | 100% | 53% | 4.25 | 6.13 | 4 mg/L EPA limit | |
| Gross alpha 1990 to 2012 | 16 | 88% | 13% | 7.58 | 31 | 15 pCi/L EPA limit | |
| Uranium 2001 to 2016 | 28 | 100% | 4% | 5.46 | 31.5 | 30 ug/L EPA limit | |
| Copper 1990 to 2012 | 38 | 71% | 0% | 0.002 | 0.018 | 1.3 mg/L EPA limit | |
| Lead 1990 to 2012 | 38 | 11% | 0% | 0 | 5.02 | 15 ug/L EPA limit | |
| Nitrate 1990 to 2012 | 38 | 92% | 0% | 2.21 | 9.95 | 10 mg/L EPA limit | |
| Radium (226 + 228) 1990 to 2016 | 30 | 60% | 0% | 0.295 | 1.4 | 5 pCi/L EPA limit | |
| Chloride 1938 to 2012 | 80 | 100% | no limit | 138 | 698 | 250 mg/L nuisance level | |
| Sodium 1938 to 2012 | 79 | 100% | no limit | 132 | 820 | 20 mg/L health guideline | |
| Manganese 1990 to 2012 | 38 | 32% | no limit | 0 | 41.8 | 300 ug/L health guideline | |
| Iron 1990 to 2012 | 38 | 42% | no limit | 0 | 247 | 300 ug/L nuisance level |
Sampled fewer than 10 times, too few to summarize: E. coli (1), Radon (5).
Get the free Gaines County well report
One email with the numbers above, what they mean for a home in Gaines County, exactly which tests to order, and what treatment fits the local profile. No spam, unsubscribe in one click.
What this means
The contaminants most often above their limit here are arsenic (71% of 38 samples), fluoride (53% of 78 samples), and gross alpha (13% of 16 samples). A well next door can differ sharply from yours because bedrock fractures, well depth and plumbing all matter, so these rates describe the area, not your tap.
Chloride is widespread in local groundwater. It is mainly a staining and taste problem, but high manganese also carries a health advisory for infants.
What to test for in Gaines County
- Volatile organic compounds (VOCs)33 leaking underground storage tank sites on record locally.
- Arsenic71% of 38 local samples were above the limit.
- Fluoride53% of 78 local samples were above the limit.
- Gross alpha13% of 16 local samples were above the limit.
- Uranium4% of 28 local samples were above the limit.
- Coliform bacteriaRecommended for every private well, every year.
- RadonMedian local reading is 450 pCi/L.
- ChlorideDetected in 100% of local samples.
Contamination sources on record in Gaines County
TCEQ records 33 leaking underground storage tank sites in Gaines County, among 36 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.
- 33
- leaking underground storage tank sitesGasoline and heating oil that leaked from tanks move through groundwater as benzene, MTBE and other volatile organic compounds.
- 3
- lined landfills and transfer facilities
Treatment that fits the local profile
- Arsenic
- Point-of-use reverse osmosis; Adsorptive media (iron-based) whole-house; Anion exchange
- Fluoride
- Point-of-use reverse osmosis; Activated alumina; Distillation
- Gross alpha
- Point-of-use reverse osmosis; Water softener (cation exchange) for radium; Anion exchange for uranium
- Uranium
- Point-of-use reverse osmosis; Anion exchange; Whole-house anion exchange
- Copper
- Neutralizing filter to raise pH; Point-of-use reverse osmosis
Get your Gaines County water tested at home
A licensed local water treatment company tests your tap water in your home, walks you through the numbers, and quotes treatment only if something needs fixing. Free, about 30 minutes, no obligation. Tell us what you need and we match you with a company that serves Gaines County.
Common questions
Is there arsenic in well water in Gaines County?
Arsenic was detected in 97% of 38 public well samples in Gaines County, and 71% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.
How high is radon in well water in Gaines County?
The median radon level across 5 public samples in Gaines County was 450 pCi/L, with a high of 640 pCi/L. New Hampshire recommends treatment above 2,000 pCi/L.
How often should I test a private well in Gaines County?
Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.
Sources
- Texas Water Development Board Groundwater Database: 518 samples in Gaines County. Water quality samples from the Texas Water Development Board Groundwater Database, collected by TWDB, groundwater conservation districts and cooperators. Retrieved September 9, 2026.
- USGS Water Quality Portal: 27 samples in Gaines County. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
- TCEQ regulated sites: 36 regulated sites located in Gaines County. Leaking petroleum storage tank sites, state Superfund sites and municipal solid waste landfills from the Texas Commission on Environmental Quality. Retrieved September 9, 2026.
Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.