Well Water Nerd

Well water in Comanche County, Texas

In Comanche County, 15% of 85 tested well samples exceeded the EPA limit for nitrate (10 mg/L), based on public data from Texas Water Development Board Groundwater Database.

158 individual samples from 82 wells, 1937 to 2023. Data refreshed September 9, 2026.

TWDB samples an ambient monitoring network of wells on a rotation, so these describe aquifers, not a survey of homeowners' tests.

What individual samples found

Each row summarizes every public sample for that contaminant inside Comanche County. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.

ContaminantSamplesDetectedAbove limitMedianHighestLimit
Nitrate
1990 to 2023
8586%15%1.866110 mg/L
EPA limit
Fluoride
1959 to 2023
15499%0%0.422.14 mg/L
EPA limit
Arsenic
1990 to 2023
851%0%01.810 ug/L
EPA limit
Lead
1990 to 2023
859%0%0615 ug/L
EPA limit
Copper
1990 to 2023
8562%0%0.0020.0381.3 mg/L
EPA limit
Radium (226 + 228)
1990 to 2011
3284%0%1.13.25 pCi/L
EPA limit
Gross alpha
1990 to 2011
2952%0%3.212.115 pCi/L
EPA limit
Uranium
2011 to 2023
2875%0%2.855.530 ug/L
EPA limit
Chloride
1937 to 2023
158100%no limit57.91,201250 mg/L
nuisance level
Sodium
1959 to 2023
156100%no limit52.848420 mg/L
health guideline
Iron
1960 to 2023
9540%no limit04,900300 ug/L
nuisance level
Manganese
1961 to 2023
8658%no limit3.0377.5300 ug/L
health guideline

Get the free Comanche County well report

One email with the numbers above, what they mean for a home in Comanche County, exactly which tests to order, and what treatment fits the local profile. No spam, unsubscribe in one click.

What this means

The contaminants most often above their limit here are nitrate (15% of 85 samples). A well next door can differ sharply from yours because bedrock fractures, well depth and plumbing all matter, so these rates describe the area, not your tap.

Chloride and Manganese are widespread in local groundwater. They are mainly a staining and taste problem, but high manganese also carries a health advisory for infants.

What to test for in Comanche County

  • Volatile organic compounds (VOCs)25 leaking underground storage tank sites on record locally.
  • Nitrate15% of 85 local samples were above the limit.
  • Coliform bacteriaRecommended for every private well, every year.
  • ChlorideDetected in 100% of local samples.
  • FluorideDetected in 99% of local samples.
  • CopperDetected in 62% of local samples.
  • ManganeseDetected in 58% of local samples.

Contamination sources on record in Comanche County

TCEQ records 25 leaking underground storage tank sites in Comanche County, among 33 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.

25
leaking underground storage tank sitesGasoline and heating oil that leaked from tanks move through groundwater as benzene, MTBE and other volatile organic compounds.
8
lined landfills and transfer facilities

Treatment that fits the local profile

Nitrate
Point-of-use reverse osmosis; Anion exchange; Distillation
Fluoride
Point-of-use reverse osmosis; Activated alumina; Distillation
Copper
Neutralizing filter to raise pH; Point-of-use reverse osmosis
Chloride
Point-of-use reverse osmosis; Distillation
Manganese
Oxidizing filter (greensand, birm) whole-house; Water softener (low levels); Point-of-use reverse osmosis

Get your Comanche County water tested at home

A licensed local water treatment company tests your tap water in your home, walks you through the numbers, and quotes treatment only if something needs fixing. Free, about 30 minutes, no obligation. Tell us what you need and we match you with a company that serves Comanche County.

What are you worried about?

The test is free and there is no obligation. Your details go only to the company named above, and we log the time and address of this request.

Common questions

Is there arsenic in well water in Comanche County?

Arsenic was detected in 1% of 85 public well samples in Comanche County, and 0% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.

How often should I test a private well in Comanche County?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Sources

  • Texas Water Development Board Groundwater Database: 1,078 samples in Comanche County. Water quality samples from the Texas Water Development Board Groundwater Database, collected by TWDB, groundwater conservation districts and cooperators. Retrieved September 9, 2026.
  • TCEQ regulated sites: 33 regulated sites located in Comanche County. Leaking petroleum storage tank sites, state Superfund sites and municipal solid waste landfills from the Texas Commission on Environmental Quality. Retrieved September 9, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.