Well Water Nerd

Well water in Wiconisco township, Pennsylvania

In Wiconisco township, manganese was detected in 100% of 67 tested well samples from USGS Water Quality Portal.

The strongest signal is coliform bacteria: Recommended for every private well, every year, too few samples to carry the headline but first on the test list below.

220 test results across 4 contaminants from at least 1 wells, 1997 to 2002; manganese has the most at 67. Data refreshed September 3, 2026.

Compiled by Nick at Well Water Nerd from public records. How these pages are built

What individual samples found

Each row summarizes every public sample for that contaminant inside Wiconisco township. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.

ContaminantAbove limitSamplesDetectedMedianHighestLimit
Manganese
1997 to 2002
no limit67100%8881,220300 ug/L
health guideline
Iron
1997 to 2002
no limit66100%10,10016,300300 ug/L
nuisance level
Sodium
1997 to 2002
no limit6394%0.81.220 mg/L
health guideline
Chloride
1997 to 1999
no limit244%01250 mg/L
nuisance level

Closer than the town

See the sampled wells near your address

The same records, drawn around one point: which wells within a few miles were sampled and what they found, how deep the wells next to you were drilled, and any leaking tank or cleanup site within a mile.

Check my address

What this means

Among contaminants with a federal limit, no tested sample in Wiconisco township came back above it. That is reassuring, but sampling is uneven: wells that were never tested are not in this data.

Manganese and Iron are widespread in local groundwater. They are mainly a staining and taste problem, but high manganese also carries a health advisory for infants.

What to test for in Wiconisco township

  1. 1
    Coliform bacteria
    Recommended for every private well, every year.
  2. 2
    Nitrate
    Recommended for every private well, especially near farms or septic systems.
  3. 3
    Manganese
    Detected in 100% of local samples.
  4. 4
    Iron
    Detected in 100% of local samples.

Test your Wiconisco township well for coliform bacteria, nitrate and manganese

Certified lab analysis of your own tap water, bottles and prepaid return shipping included. The Essential well panel covers arsenic, uranium, nitrate, lead, copper, manganese, iron, sodium and bacteria; radon and PFAS are add-ons.

Order the Tap Score well water test kit, from $209Already tested? Upload the report

Just want bacteria checked first? Tap Score coliform and E. coli test, $99. Coliform and E. coli are the tests every well needs every year.

Want a quick look before paying for a lab? Home well water test strips on Amazon check hardness, iron, pH and nitrate in minutes. They are a screen, not a result: arsenic, bacteria, uranium and PFAS need a certified lab.

Affiliate links: the merchant pays us a commission and the price is the same for you. It does not change what the data above says. As an Amazon Associate we earn from qualifying purchases.

Where to get a well tested in Pennsylvania: certified labs, state programs and prices.

Already have results back? Get your lab report read against the Wiconisco township numbers, $29. Every line explained, ranked by what matters, with the fix for each.

Wells in Wiconisco township

36 domestic wells in Wiconisco township are on record with the state. 100% are drilled into bedrock, and the typical well is 160 feet deep (one in ten goes past 300 feet).

In a typical Wiconisco township well, bedrock starts about 18 feet down, the median yield is 15 gallons per minute, 4% of wells yield under 3 gallons per minute and usually need a storage tank.

Bedrock wells are where arsenic, uranium and radon come from: the water sits in fractures in granite and metamorphic rock and picks up whatever the rock carries. That is why testing for those three matters more here than in a dug or gravel well.

Find your own well's report

The state keeps the driller's report for most wells drilled since 1984. It tells you how deep your well is, where bedrock starts, and how much water it makes, which decides what treatment can work.

  1. Open PaGWIS (Pennsylvania Geological Survey) and choose Water Well.
  2. The record lists depth, depth to bedrock, yield and use; drillers have reported new wells to the state since 1966.

Pennsylvania has no private well construction standard and does not require testing, so many older wells have no record at all.

The rock under Wiconisco township

Valley and Ridge aquifers

Sandstone and carbonate-rock. Layered sandstone and limestone means a well may draw from either. Hardness and iron are routine, and the limestone layers can carry bacteria and nitrate from the surface quickly, so test for both yearly.

Classification from the USGS Principal Aquifers of the United States (national map, 2003 edition, GIS release 2015), read at the town centroid. A single well can sit in a different unit, especially near a boundary.

Official help in Pennsylvania

Two places to start that are not selling anything: the state program that answers private well questions, and its list of labs certified to run drinking water tests. A certified lab is the difference between a result you can act on and a number.

Treatment that fits the local profile

Manganese

Oxidizing filter (greensand, birm) whole-house; Water softener (low levels); Point-of-use reverse osmosis

Iron

Oxidizing filter whole-house; Water softener (low levels); Aeration plus filtration

Systems we would look at first

Some links below are affiliate links. If you buy through one, the merchant pays us a commission at no extra cost to you. It does not change which products we list or what the data says.

For manganese

Iron and manganese oxidizing filter

whole-house, at the point of entry, about $1,800

Air-injection or greensand media; fixes staining at the source.

Free, no obligation

Get on the list for a free in-home water test in Wiconisco township

No water treatment company serves Wiconisco township through Well Water Nerd yet. We are signing licensed companies on county by county: they test at your tap for free, walk you through the numbers, and quote treatment only if something needs fixing. Leave your details and you are first in line. Nothing is shared until a company joins for Wiconisco township, and you get an email naming it first.

What are you worried about?

The test is free and there is no obligation. No company is named yet; your details stay with us until one joins for your area, and we log the time and address of this request.

Common questions

How deep are wells in Wiconisco township?

The typical domestic well in Wiconisco township is 160 feet deep, based on 36 wells reported to the state. One in ten is deeper than 300 feet. 100% are drilled into bedrock.

How often should I test a private well in Wiconisco township?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Towns near Wiconisco township

Closest first. Groundwater does not stop at a line on a map, so the next town over is a fair second opinion.

Want the numbers themselves? Download the Pennsylvania dataset as CSV, every county and town, with the sources named.

Sources

  • USGS Water Quality Portal: 220 samples in Wiconisco township. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
  • Pennsylvania Groundwater Information System (PaGWIS) wells: 59 well records in Wiconisco township, 36 domestic. Water well records from the Pennsylvania Groundwater Information System, Pennsylvania Geological Survey (DCNR). Only aggregates are shown; owner names and addresses are never stored. Retrieved September 16, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.