Well Water Nerd

Well water in Dayton, Ohio

In Dayton, 1% of 67 tested well samples exceeded the EPA limit for nitrate (10 mg/L), based on public data from USGS Water Quality Portal.

The strongest signal is arsenic: 15% of 13 local samples were above the limit, too few samples to carry the headline but first on the test list below.

357 test results across 11 contaminants from at least 45 wells, 1976 to 2014; nitrate has the most at 67. Data refreshed September 3, 2026.

Compiled by Nick at Well Water Nerd from public records. How these pages are built

What individual samples found

Each row summarizes every public sample for that contaminant inside Dayton. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.

ContaminantAbove limitSamplesDetectedMedianHighestLimit
Arsenic
2002 to 2014
1392%7.916.210 ug/L
EPA limit
Nitrate
1976 to 2003
6770%0.1810.610 mg/L
EPA limit
Fluoride
1980 to 2014
35100%0.30.414 mg/L
EPA limit
Lead
1997 to 2014
1443%01115 ug/L
EPA limit
Copper
1997 to 2014
1471%0.0010.0141.3 mg/L
EPA limit
Sodium
1976 to 2014
no limit51100%3016020 mg/L
health guideline
Manganese
1976 to 2014
no limit5194%110590300 ug/L
health guideline
Iron
1976 to 2014
no limit51100%93010,000300 ug/L
nuisance level
Chloride
1976 to 2014
no limit51100%59300250 mg/L
nuisance level

Sampled fewer than 10 times, too few to summarize: Uranium (5), E. coli (5).

Over time

Share of samples above the limit by period. A cell needs ten samples to show; a comparison needs twenty in each period. Later periods sample fewer wells, and often the ones already known to have a problem.

Contaminantbefore 20002000s2010s2020s
Nitrate2%57 samples0%10 samplesn/an/a

Closer than the town

See the sampled wells near your address

The same records, drawn around one point: which wells within a few miles were sampled and what they found, how deep the wells next to you were drilled, and any leaking tank or cleanup site within a mile.

Check my address

What this means

The contaminants most often above their limit here are arsenic (15% of 13 samples) and nitrate (1% of 67 samples). A well next door can differ sharply from yours because bedrock fractures, well depth and plumbing all matter, so these rates describe the area, not your tap.

Manganese, Iron, and Chloride are widespread in local groundwater. They are mainly a staining and taste problem, but high manganese also carries a health advisory for infants.

What to test for in Dayton

  1. 1
    Arsenic
    15% of 13 local samples were above the limit.
  2. 2
    Nitrate
    1% of 67 local samples were above the limit.
  3. 3
    Coliform bacteria
    Recommended for every private well, every year.
  4. 4
    Fluoride
    Detected in 100% of local samples.
  5. 5
    Iron
    Detected in 100% of local samples.
  6. 6
    Chloride
    Detected in 100% of local samples.
  7. 7
    Manganese
    Detected in 94% of local samples.
  8. 8
    Volatile organic compounds (VOCs)
    782 leaking underground storage tank sites on record locally.
  9. 9
    Metals panel
    47 hazardous waste sites on record locally.

Test your Dayton well for arsenic, nitrate and coliform bacteria

Certified lab analysis of your own tap water, bottles and prepaid return shipping included. The Essential well panel covers arsenic, uranium, nitrate, lead, copper, manganese, iron, sodium and bacteria; radon and PFAS are add-ons.

Order the Tap Score well water test kit, from $209Already tested? Upload the report

Just want bacteria checked first? Tap Score coliform and E. coli test, $99. Coliform and E. coli are the tests every well needs every year.

Want a quick look before paying for a lab? Home well water test strips on Amazon check hardness, iron, pH and nitrate in minutes. They are a screen, not a result: arsenic, bacteria, uranium and PFAS need a certified lab.

Affiliate links: the merchant pays us a commission and the price is the same for you. It does not change what the data above says. As an Amazon Associate we earn from qualifying purchases.

Where to get a well tested in Ohio: certified labs, state programs and prices.

Already have results back? Get your lab report read against the Dayton numbers, $29. Every line explained, ranked by what matters, with the fix for each.

Wells in Dayton

179 domestic wells in Dayton are on record with the state since 1971. 26% are drilled into bedrock, and the typical well is 72 feet deep (one in ten goes past 118 feet).

In a typical Dayton well, bedrock starts about 24 feet down, the median yield is 13.5 gallons per minute, 4% of wells yield under 3 gallons per minute and usually need a storage tank.

26
1970s
27
1980s
6
1990s
8
2000s

Find your own well's report

The state keeps the driller's report for most wells drilled since 1984. It tells you how deep your well is, where bedrock starts, and how much water it makes, which decides what treatment can work.

  1. Open ODNR water well log search and choose Water Well.
  2. The log lists depth, depth to bedrock, casing, static water level, the pump test and the driller.

Ohio has required well logs since 1948, so most drilled wells have one.

The rock under Dayton

Not a principal aquifer

The USGS map places this area outside any principal aquifer, which usually means wells here draw from fractured bedrock or thin local deposits rather than a large regional aquifer. Bedrock wells of that kind are where arsenic, radon and uranium turn up, and yields vary from well to well.

Classification from the USGS Principal Aquifers of the United States (national map, 2003 edition, GIS release 2015), read at the town centroid. A single well can sit in a different unit, especially near a boundary.

Official help in Ohio

Two places to start that are not selling anything: the state program that answers private well questions, and its list of labs certified to run drinking water tests. A certified lab is the difference between a result you can act on and a number.

Contamination sources on record in Dayton

Ohio EPA records 782 leaking underground storage tank sites and 47 hazardous waste sites in Dayton, among 857 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.

782
leaking underground storage tank sitesGasoline and heating oil that leaked from tanks move through groundwater as benzene, MTBE and other volatile organic compounds.
47
hazardous waste sitesSolvents, degreasers and metals from industrial sites can travel far in fractured bedrock.
8
lined landfills and transfer facilities
20
other remediation projects

Treatment that fits the local profile

Arsenic

Point-of-use reverse osmosis; Adsorptive media (iron-based) whole-house; Anion exchange

Nitrate

Point-of-use reverse osmosis; Anion exchange; Distillation

Iron

Oxidizing filter whole-house; Water softener (low levels); Aeration plus filtration

Manganese

Oxidizing filter (greensand, birm) whole-house; Water softener (low levels); Point-of-use reverse osmosis

Systems we would look at first

Some links below are affiliate links. If you buy through one, the merchant pays us a commission at no extra cost to you. It does not change which products we list or what the data says.

For arsenic

Under-sink reverse osmosis system

under-sink or countertop, about $300

Look for NSF/ANSI 58 certification listing the contaminant you need removed.

For arsenic

Whole-house arsenic and uranium filter

whole-house, at the point of entry, about $2,500

Adsorptive iron-based media; sized to your well yield.

For arsenic

Aquasana SmartFlow reverse osmosis

under-sink or countertop, about $225

Certified to NSF/ANSI 58 and 53 to reduce arsenic (96%, pentavalent), fluoride (90%), lead (99%), nitrate, nitrite and PFOA/PFOS at the kitchen tap, with a remineralizer.

For manganese

Iron and manganese oxidizing filter

whole-house, at the point of entry, about $1,800

Air-injection or greensand media; fixes staining at the source.

Free, no obligation

Get on the list for a free in-home water test in Dayton

No water treatment company serves Dayton through Well Water Nerd yet. We are signing licensed companies on county by county: they test at your tap for free, walk you through the numbers, and quote treatment only if something needs fixing. Leave your details and you are first in line. Nothing is shared until a company joins for Dayton, and you get an email naming it first.

What are you worried about?

The test is free and there is no obligation. No company is named yet; your details stay with us until one joins for your area, and we log the time and address of this request.

Common questions

How deep are wells in Dayton?

The typical domestic well in Dayton is 72 feet deep, based on 179 wells reported to the state since 1971. One in ten is deeper than 118 feet. 26% are drilled into bedrock.

Is there arsenic in well water in Dayton?

Arsenic was detected in 92% of 13 public well samples in Dayton, and 15% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.

How often should I test a private well in Dayton?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Towns near Dayton

Closest first. Groundwater does not stop at a line on a map, so the next town over is a fair second opinion.

Want the numbers themselves? Download the Ohio dataset as CSV, every county and town, with the sources named.

Sources

  • USGS Water Quality Portal: 357 samples in Dayton. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
  • Ohio DNR water well logs: 1,383 well records in Dayton, 179 domestic. Water well logs filed with the Ohio Department of Natural Resources Division of Water Resources since 1948. Only aggregates are shown; owner names and addresses are never stored. Retrieved September 17, 2026.
  • Ohio EPA regulated sites: 857 regulated sites located in Dayton. Remediation sites, leaking underground storage tank releases (BUSTR) and landfills from the Ohio Environmental Protection Agency and the Division of State Fire Marshal. Retrieved September 17, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.