Well Water Nerd

Well water in Monclova township, Ohio

In Monclova township, none of 48 tested well samples exceeded the EPA limit for nitrate, based on public data from USGS Water Quality Portal.

The strongest signal is lead: 12% of 25 local samples were above the limit, too few samples to carry the headline but first on the test list below.

4,605 test results across 10 contaminants from at least 46 wells, 1987 to 1999; chloride has the most at 2,250. Data refreshed September 3, 2026.

Compiled by Nick at Well Water Nerd from public records. How these pages are built

What individual samples found

Each row summarizes every public sample for that contaminant inside Monclova township. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.

ContaminantAbove limitSamplesDetectedMedianHighestLimit
Lead
1987 to 1999
2520%02015 ug/L
EPA limit
Nitrate
1987 to 1999
4888%0.7659.510 mg/L
EPA limit
Fluoride
1987 to 1999
4370%0.10.84 mg/L
EPA limit
Copper
1987 to 1999
254%00.0071.3 mg/L
EPA limit
Arsenic
1987 to 1996
1580%1210 ug/L
EPA limit
Chloride
1987 to 1999
no limit2,250100%72.91,020250 mg/L
nuisance level
Sodium
1987 to 1999
no limit2,146100%21.349020 mg/L
health guideline
Iron
1987 to 1999
no limit26100%3435,500300 ug/L
nuisance level
Manganese
1987 to 1999
no limit26100%691,800300 ug/L
health guideline

Sampled fewer than 10 times, too few to summarize: Uranium (1).

Closer than the town

See the sampled wells near your address

The same records, drawn around one point: which wells within a few miles were sampled and what they found, how deep the wells next to you were drilled, and any leaking tank or cleanup site within a mile.

Check my address

What this means

The contaminants most often above their limit here are lead (12% of 25 samples). A well next door can differ sharply from yours because bedrock fractures, well depth and plumbing all matter, so these rates describe the area, not your tap.

Chloride, Iron, and Manganese are widespread in local groundwater. They are mainly a staining and taste problem, but high manganese also carries a health advisory for infants.

What to test for in Monclova township

  1. 1
    Lead
    12% of 25 local samples were above the limit.
  2. 2
    Coliform bacteria
    Recommended for every private well, every year.
  3. 3
    Nitrate
    Recommended for every private well, especially near farms or septic systems.
  4. 4
    Iron
    Detected in 100% of local samples.
  5. 5
    Manganese
    Detected in 100% of local samples.
  6. 6
    Chloride
    Detected in 100% of local samples.
  7. 7
    Fluoride
    Detected in 70% of local samples.
  8. 8
    Volatile organic compounds (VOCs)
    25 leaking underground storage tank sites on record locally.

Test your Monclova township well for lead, coliform bacteria and nitrate

Certified lab analysis of your own tap water, bottles and prepaid return shipping included. The Essential well panel covers arsenic, uranium, nitrate, lead, copper, manganese, iron, sodium and bacteria; radon and PFAS are add-ons.

Order the Tap Score well water test kit, from $209Already tested? Upload the report

Just want bacteria checked first? Tap Score coliform and E. coli test, $99. Coliform and E. coli are the tests every well needs every year.

Want a quick look before paying for a lab? Home well water test strips on Amazon check hardness, iron, pH and nitrate in minutes. They are a screen, not a result: arsenic, bacteria, uranium and PFAS need a certified lab.

Affiliate links: the merchant pays us a commission and the price is the same for you. It does not change what the data above says. As an Amazon Associate we earn from qualifying purchases.

Where to get a well tested in Ohio: certified labs, state programs and prices.

Already have results back? Get your lab report read against the Monclova township numbers, $29. Every line explained, ranked by what matters, with the fix for each.

Wells in Monclova township

641 domestic wells in Monclova township are on record with the state since 1970. 91% are drilled into bedrock, and the typical well is 75 feet deep (one in ten goes past 116 feet).

In a typical Monclova township well, bedrock starts about 50 feet down, the median yield is 10 gallons per minute, 1% of wells yield under 3 gallons per minute and usually need a storage tank.

Bedrock wells are where arsenic, uranium and radon come from: the water sits in fractures in granite and metamorphic rock and picks up whatever the rock carries. That is why testing for those three matters more here than in a dug or gravel well.

62
1970s
89
1980s
262
1990s
97
2000s

Find your own well's report

The state keeps the driller's report for most wells drilled since 1984. It tells you how deep your well is, where bedrock starts, and how much water it makes, which decides what treatment can work.

  1. Open ODNR water well log search and choose Water Well.
  2. The log lists depth, depth to bedrock, casing, static water level, the pump test and the driller.

Ohio has required well logs since 1948, so most drilled wells have one.

The rock under Monclova township

Silurian-Devonian aquifers

Carbonate-rock. Limestone and dolomite move water through cracks and solution channels, sometimes very fast. Bacteria and nitrate can travel from the surface to a well in days, so annual bacteria testing matters more here than most places; hardness is a given.

Classification from the USGS Principal Aquifers of the United States (national map, 2003 edition, GIS release 2015), read at the town centroid. A single well can sit in a different unit, especially near a boundary.

Official help in Ohio

Two places to start that are not selling anything: the state program that answers private well questions, and its list of labs certified to run drinking water tests. A certified lab is the difference between a result you can act on and a number.

Contamination sources on record in Monclova township

Ohio EPA records 25 leaking underground storage tank sites in Monclova township, among 26 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.

25
leaking underground storage tank sitesGasoline and heating oil that leaked from tanks move through groundwater as benzene, MTBE and other volatile organic compounds.
1
other remediation project

Treatment that fits the local profile

Lead

Point-of-use reverse osmosis; Certified lead-removal carbon filter; Neutralizing filter to raise pH and stop leaching

Iron

Oxidizing filter whole-house; Water softener (low levels); Aeration plus filtration

Manganese

Oxidizing filter (greensand, birm) whole-house; Water softener (low levels); Point-of-use reverse osmosis

Chloride

Point-of-use reverse osmosis; Distillation

Systems we would look at first

Some links below are affiliate links. If you buy through one, the merchant pays us a commission at no extra cost to you. It does not change which products we list or what the data says.

For lead

Under-sink reverse osmosis system

under-sink or countertop, about $300

Look for NSF/ANSI 58 certification listing the contaminant you need removed.

For lead

Acid neutralizing filter

whole-house, at the point of entry, about $1,200

Raises pH so plumbing stops leaching lead and copper.

For lead

Aquasana SmartFlow reverse osmosis

under-sink or countertop, about $225

Certified to NSF/ANSI 58 and 53 to reduce arsenic (96%, pentavalent), fluoride (90%), lead (99%), nitrate, nitrite and PFOA/PFOS at the kitchen tap, with a remineralizer.

For iron

Iron and manganese oxidizing filter

whole-house, at the point of entry, about $1,800

Air-injection or greensand media; fixes staining at the source.

Free, no obligation

Get on the list for a free in-home water test in Monclova township

No water treatment company serves Monclova township through Well Water Nerd yet. We are signing licensed companies on county by county: they test at your tap for free, walk you through the numbers, and quote treatment only if something needs fixing. Leave your details and you are first in line. Nothing is shared until a company joins for Monclova township, and you get an email naming it first.

What are you worried about?

The test is free and there is no obligation. No company is named yet; your details stay with us until one joins for your area, and we log the time and address of this request.

Common questions

How deep are wells in Monclova township?

The typical domestic well in Monclova township is 75 feet deep, based on 641 wells reported to the state since 1970. One in ten is deeper than 116 feet. 91% are drilled into bedrock.

Is there arsenic in well water in Monclova township?

Arsenic was detected in 80% of 15 public well samples in Monclova township, and 0% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.

How often should I test a private well in Monclova township?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Towns near Monclova township

Closest first. Groundwater does not stop at a line on a map, so the next town over is a fair second opinion.

Want the numbers themselves? Download the Ohio dataset as CSV, every county and town, with the sources named.

Sources

  • USGS Water Quality Portal: 4,605 samples in Monclova township. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
  • Ohio DNR water well logs: 677 well records in Monclova township, 641 domestic. Water well logs filed with the Ohio Department of Natural Resources Division of Water Resources since 1948. Only aggregates are shown; owner names and addresses are never stored. Retrieved September 17, 2026.
  • Ohio EPA regulated sites: 26 regulated sites located in Monclova township. Remediation sites, leaking underground storage tank releases (BUSTR) and landfills from the Ohio Environmental Protection Agency and the Division of State Fire Marshal. Retrieved September 17, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.