Well water in Colerain township, Ohio
In Colerain township, 4% of 54 tested well samples exceeded the EPA limit for lead (15 ug/L), based on public data from USGS Water Quality Portal.
767 test results across 10 contaminants from at least 3 wells, 1972 to 2013; nitrate has the most at 183. Data refreshed September 3, 2026.
Compiled by Nick at Well Water Nerd from public records. How these pages are built
What individual samples found
Each row summarizes every public sample for that contaminant inside Colerain township. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.
| Contaminant | Above limit | Samples | Detected | Median | Highest | Limit |
|---|---|---|---|---|---|---|
| Lead 1973 to 2013 | 54 | 50% | 0 | 48 | 15 ug/L EPA limit | |
| Arsenic 1972 to 2013 | 50 | 22% | 0 | 12 | 10 ug/L EPA limit | |
| Nitrate 1972 to 2000 | 183 | 98% | 2 | 15.4 | 10 mg/L EPA limit | |
| Fluoride 1972 to 2013 | 92 | 100% | 0.3 | 1.1 | 4 mg/L EPA limit | |
| Copper 1972 to 2013 | 54 | 91% | 0.002 | 0.03 | 1.3 mg/L EPA limit | |
| Manganese 1972 to 2013 | no limit | 95 | 100% | 260 | 463 | 300 ug/L health guideline |
| Iron 1972 to 2013 | no limit | 95 | 96% | 48 | 1,040 | 300 ug/L nuisance level |
| Chloride 1972 to 2013 | no limit | 94 | 100% | 49 | 83 | 250 mg/L nuisance level |
| Sodium 1984 to 2013 | no limit | 49 | 100% | 33 | 50 | 20 mg/L health guideline |
Sampled fewer than 10 times, too few to summarize: Uranium (1).
Closer than the town
See the sampled wells near your address
The same records, drawn around one point: which wells within a few miles were sampled and what they found, how deep the wells next to you were drilled, and any leaking tank or cleanup site within a mile.
Check my addressWhat this means
The contaminants most often above their limit here are lead (4% of 54 samples), arsenic (2% of 50 samples), and nitrate (2% of 183 samples). A well next door can differ sharply from yours because bedrock fractures, well depth and plumbing all matter, so these rates describe the area, not your tap.
Manganese, Iron, and Chloride are widespread in local groundwater. They are mainly a staining and taste problem, but high manganese also carries a health advisory for infants.
What to test for in Colerain township
- 1Lead4% of 54 local samples were above the limit.
- 2Arsenic2% of 50 local samples were above the limit.
- 3Nitrate2% of 183 local samples were above the limit.
- 4Coliform bacteriaRecommended for every private well, every year.
- 5FluorideDetected in 100% of local samples.
- 6ManganeseDetected in 100% of local samples.
- 7ChlorideDetected in 100% of local samples.
- 8Volatile organic compounds (VOCs)150 leaking underground storage tank sites on record locally.
- 9Metals panel4 hazardous waste sites on record locally.
Test your Colerain township well for lead, arsenic and nitrate
Certified lab analysis of your own tap water, bottles and prepaid return shipping included. The Essential well panel covers arsenic, uranium, nitrate, lead, copper, manganese, iron, sodium and bacteria; radon and PFAS are add-ons.
Order the Tap Score well water test kit, from $209Already tested? Upload the report
Just want bacteria checked first? Tap Score coliform and E. coli test, $99. Coliform and E. coli are the tests every well needs every year.
Want a quick look before paying for a lab? Home well water test strips on Amazon check hardness, iron, pH and nitrate in minutes. They are a screen, not a result: arsenic, bacteria, uranium and PFAS need a certified lab.
Affiliate links: the merchant pays us a commission and the price is the same for you. It does not change what the data above says. As an Amazon Associate we earn from qualifying purchases.
Where to get a well tested in Ohio: certified labs, state programs and prices.
Already have results back? Get your lab report read against the Colerain township numbers, $29. Every line explained, ranked by what matters, with the fix for each.
Wells in Colerain township
69 domestic wells in Colerain township are on record with the state since 1971. 84% are drilled into bedrock, and the typical well is 75 feet deep (one in ten goes past 101 feet).
In a typical Colerain township well, bedrock starts about 30 feet down, the median yield is 3 gallons per minute, 47% of wells yield under 3 gallons per minute and usually need a storage tank.
Bedrock wells are where arsenic, uranium and radon come from: the water sits in fractures in granite and metamorphic rock and picks up whatever the rock carries. That is why testing for those three matters more here than in a dug or gravel well.
Find your own well's report
The state keeps the driller's report for most wells drilled since 1984. It tells you how deep your well is, where bedrock starts, and how much water it makes, which decides what treatment can work.
- Open ODNR water well log search and choose Water Well.
- The log lists depth, depth to bedrock, casing, static water level, the pump test and the driller.
Ohio has required well logs since 1948, so most drilled wells have one.
The rock under Colerain township
Not a principal aquifer
The USGS map places this area outside any principal aquifer, which usually means wells here draw from fractured bedrock or thin local deposits rather than a large regional aquifer. Bedrock wells of that kind are where arsenic, radon and uranium turn up, and yields vary from well to well.
Classification from the USGS Principal Aquifers of the United States (national map, 2003 edition, GIS release 2015), read at the town centroid. A single well can sit in a different unit, especially near a boundary.
Official help in Ohio
Two places to start that are not selling anything: the state program that answers private well questions, and its list of labs certified to run drinking water tests. A certified lab is the difference between a result you can act on and a number.
- Private Water Systems Program, Ohio Department of Health
- Laboratory Certification, Ohio EPA
Contamination sources on record in Colerain township
Ohio EPA records 150 leaking underground storage tank sites and 4 hazardous waste sites in Colerain township, among 158 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.
- 150
- leaking underground storage tank sitesGasoline and heating oil that leaked from tanks move through groundwater as benzene, MTBE and other volatile organic compounds.
- 4
- hazardous waste sitesSolvents, degreasers and metals from industrial sites can travel far in fractured bedrock.
- 1
- lined landfill or transfer facility
- 3
- other remediation projects
Treatment that fits the local profile
Lead
Point-of-use reverse osmosis; Certified lead-removal carbon filter; Neutralizing filter to raise pH and stop leaching
Arsenic
Point-of-use reverse osmosis; Adsorptive media (iron-based) whole-house; Anion exchange
Nitrate
Point-of-use reverse osmosis; Anion exchange; Distillation
Manganese
Oxidizing filter (greensand, birm) whole-house; Water softener (low levels); Point-of-use reverse osmosis
Systems we would look at first
Some links below are affiliate links. If you buy through one, the merchant pays us a commission at no extra cost to you. It does not change which products we list or what the data says.
For lead
Under-sink reverse osmosis system
under-sink or countertop, about $300
Look for NSF/ANSI 58 certification listing the contaminant you need removed.
For lead
Acid neutralizing filter
whole-house, at the point of entry, about $1,200
Raises pH so plumbing stops leaching lead and copper.
For lead
Aquasana SmartFlow reverse osmosis
under-sink or countertop, about $225
Certified to NSF/ANSI 58 and 53 to reduce arsenic (96%, pentavalent), fluoride (90%), lead (99%), nitrate, nitrite and PFOA/PFOS at the kitchen tap, with a remineralizer.
For arsenic
Whole-house arsenic and uranium filter
whole-house, at the point of entry, about $2,500
Adsorptive iron-based media; sized to your well yield.
For manganese
Iron and manganese oxidizing filter
whole-house, at the point of entry, about $1,800
Air-injection or greensand media; fixes staining at the source.
Free, no obligation
Get on the list for a free in-home water test in Colerain township
No water treatment company serves Colerain township through Well Water Nerd yet. We are signing licensed companies on county by county: they test at your tap for free, walk you through the numbers, and quote treatment only if something needs fixing. Leave your details and you are first in line. Nothing is shared until a company joins for Colerain township, and you get an email naming it first.
Common questions
How deep are wells in Colerain township?
The typical domestic well in Colerain township is 75 feet deep, based on 69 wells reported to the state since 1971. One in ten is deeper than 101 feet. 84% are drilled into bedrock.
Is there arsenic in well water in Colerain township?
Arsenic was detected in 22% of 50 public well samples in Colerain township, and 2% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.
How often should I test a private well in Colerain township?
Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.
Towns near Colerain township
Closest first. Groundwater does not stop at a line on a map, so the next town over is a fair second opinion.
Want the numbers themselves? Download the Ohio dataset as CSV, every county and town, with the sources named.
Sources
- USGS Water Quality Portal: 767 samples in Colerain township. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
- Ohio DNR water well logs: 218 well records in Colerain township, 69 domestic. Water well logs filed with the Ohio Department of Natural Resources Division of Water Resources since 1948. Only aggregates are shown; owner names and addresses are never stored. Retrieved September 17, 2026.
- Ohio EPA regulated sites: 158 regulated sites located in Colerain township. Remediation sites, leaking underground storage tank releases (BUSTR) and landfills from the Ohio Environmental Protection Agency and the Division of State Fire Marshal. Retrieved September 17, 2026.
Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.