Well water in Lancaster County, Nebraska
In Lancaster County, 8% of 4,465 tested well samples exceeded the EPA limit for nitrate (10 mg/L), based on public data from Nebraska Groundwater Quality Clearinghouse and USGS Water Quality Portal.
4,465 individual samples from 2,128 wells, 1949 to 2024. Data refreshed September 9, 2026.
What individual samples found
Each row summarizes every public sample for that contaminant inside Lancaster County. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.
| Contaminant | Samples | Detected | Above limit | Median | Highest | Limit | |
|---|---|---|---|---|---|---|---|
| Nitrate 1949 to 2024 | 4,465 | 96% | 8% | 0.5 | 118 | 10 mg/L EPA limit | |
| Radon 1994 to 1995 | 30 | 100% | no limit | 445 | 1,200 | 2,000 pCi/L health guideline |
Sampled fewer than 10 times, too few to summarize: Uranium (2), Radium (226 + 228) (1), Fluoride (1), Manganese (6), Iron (6), Chloride (6), Sodium (4).
Get the free Lancaster County well report
One email with the numbers above, what they mean for a home in Lancaster County, exactly which tests to order, and what treatment fits the local profile. No spam, unsubscribe in one click.
What this means
The contaminants most often above their limit here are nitrate (8% of 4,465 samples). A well next door can differ sharply from yours because bedrock fractures, well depth and plumbing all matter, so these rates describe the area, not your tap.
Manganese, Iron, and Chloride are widespread in local groundwater. They are mainly a staining and taste problem, but high manganese also carries a health advisory for infants.
What to test for in Lancaster County
- Nitrate8% of 4,465 local samples were above the limit.
- Coliform bacteriaRecommended for every private well, every year.
- RadonMedian local reading is 445 pCi/L.
- FluorideDetected in 100% of local samples.
- ChlorideDetected in 100% of local samples.
- ManganeseDetected in 83% of local samples.
- IronDetected in 83% of local samples.
Treatment that fits the local profile
- Nitrate
- Point-of-use reverse osmosis; Anion exchange; Distillation
- Fluoride
- Point-of-use reverse osmosis; Activated alumina; Distillation
- Manganese
- Oxidizing filter (greensand, birm) whole-house; Water softener (low levels); Point-of-use reverse osmosis
- Iron
- Oxidizing filter whole-house; Water softener (low levels); Aeration plus filtration
- Chloride
- Point-of-use reverse osmosis; Distillation
Get your Lancaster County water tested at home
A licensed local water treatment company tests your tap water in your home, walks you through the numbers, and quotes treatment only if something needs fixing. Free, about 30 minutes, no obligation. Tell us what you need and we match you with a company that serves Lancaster County.
Common questions
How high is radon in well water in Lancaster County?
The median radon level across 30 public samples in Lancaster County was 445 pCi/L, with a high of 1,200 pCi/L. New Hampshire recommends treatment above 2,000 pCi/L.
How often should I test a private well in Lancaster County?
Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.
Sources
- Nebraska Groundwater Quality Clearinghouse: 4,462 samples in Lancaster County. Groundwater quality results compiled by the Nebraska Department of Environment and Energy, University of Nebraska and Nebraska Department of Agriculture in the Groundwater Quality Clearinghouse, contributed by Natural Resources Districts and state agencies. Retrieved September 9, 2026.
- USGS Water Quality Portal: 59 samples in Lancaster County. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.