In Arundel, 29% of 63 private wells tested had arsenic above the Maine guideline (10 ug/L), according to Maine CDC.
89 private wells tested in state summaries; 36 individual samples from 36 wells, 1961 to 2026. Data refreshed September 3, 2026.
Maine DEP samples private wells near fields where sludge or septage was spread and near other known PFAS sources, and resamples detections. PFAS shares describe wells that were tested for a reason, not every well in the area. In that targeted sampling, 8% of 36 PFOS results in Arundel were above the EPA limit of 4 ng/L. In that targeted sampling, 6% of 36 PFOA results in Arundel were above the EPA limit of 4 ng/L.
What homeowner tests found
Maine Tracking Network private well summaries: private wells tested and reported to the state. Shares are against the level the state applies to each contaminant, named in the last column; several are stricter than EPA.
What individual samples found
Each row summarizes every public sample for that contaminant inside Arundel. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.
| Contaminant | Samples | Detected | Above limit | Median | Highest | Limit | |
|---|---|---|---|---|---|---|---|
| PFOS 2017 to 2026 | 36 | 39% | 8% | 0 | 30.6 | 4 ng/L EPA limit | |
| PFOA 2017 to 2026 | 36 | 42% | 6% | 0 | 17.9 | 4 ng/L EPA limit | |
| PFHxS 2017 to 2026 | 36 | 25% | 0% | 0 | 3.07 | 10 ng/L EPA limit | |
| PFNA 2017 to 2026 | 36 | 6% | 0% | 0 | 0.42 | 10 ng/L EPA limit |
Sampled fewer than 10 times, too few to summarize: Arsenic (4), Nitrate (6), Copper (4), Uranium (4), Radium (226 + 228) (3), E. coli (2), Lead (1), Chloride (7), Iron (2), Manganese (1), Radon (1).
Get the free Arundel well report
One email with the numbers above, what they mean for a home in Arundel, exactly which tests to order, and what treatment fits the local profile. No spam, unsubscribe in one click.
What this means
Among homeowners in Arundel who sent a sample to the state lab, the health-based limits most often exceeded were arsenic (29% of 63 wells), fluoride (6% of 89 wells), and uranium (2% of 52 wells). These are ordinary wells tested by their owners, so the shares are the best available picture of a typical well here, with one caveat: people test more often when they suspect a problem.
What to test for in Arundel
- Volatile organic compounds (VOCs)3 leaking underground storage tank sites on record locally.
- PFAS1 unlined landfill on record locally.
- Metals panel3 hazardous waste sites on record locally.
- Arsenic29% of 63 local wells tested were above the Maine guideline.
- PFOS8% of 36 local samples were above the limit.
- Fluoride6% of 89 local wells tested were above the Maine guideline.
- PFOA6% of 36 local samples were above the limit.
- Manganese4% of 51 local wells tested were above the Maine guideline.
- Uranium2% of 52 local wells tested were above the Maine guideline.
- Coliform bacteriaRecommended for every private well, every year.
- RadonMedian local reading is 1,300 pCi/L.
Wells in Arundel
520 domestic wells in Arundel are on record with the state since 1970. 98% are drilled into bedrock, and the typical well is 310 feet deep (one in ten goes past 505 feet).
In a typical Arundel well, bedrock starts about 25 feet down, the median yield is 6 gallons per minute, 21% of wells yield under 3 gallons per minute and usually need a storage tank.
Bedrock wells are where arsenic, uranium and radon come from: the water sits in fractures in granite and metamorphic rock and picks up whatever the rock carries. That is why testing for those three matters more here than in a dug or gravel well.
Contamination sources on record in Arundel
Maine DEP records 3 leaking underground storage tank sites, 1 unlined landfill, and 3 hazardous waste sites in Arundel, among 9 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.
- 3
- leaking underground storage tank sitesGasoline and heating oil that leaked from tanks move through groundwater as benzene, MTBE and other volatile organic compounds.
- 1
- unlined landfillOlder unlined landfills are a leading source of PFAS, VOCs and metals in nearby wells.
- 3
- hazardous waste sitesSolvents, degreasers and metals from industrial sites can travel far in fractured bedrock.
- 2
- other remediation projects
Treatment that fits the local profile
- Arsenic
- Point-of-use reverse osmosis; Adsorptive media (iron-based) whole-house; Anion exchange
- Fluoride
- Point-of-use reverse osmosis; Activated alumina; Distillation
- PFOS
- Granular activated carbon whole-house; Point-of-use reverse osmosis; Anion exchange
- PFOA
- Granular activated carbon whole-house; Point-of-use reverse osmosis; Anion exchange
- Chloride
- Point-of-use reverse osmosis; Distillation
- Iron
- Oxidizing filter whole-house; Water softener (low levels); Aeration plus filtration
Book a free water test in Arundel
A licensed local water treatment company tests your tap water in your home, walks you through the numbers, and quotes treatment only if something needs fixing. Free, about 30 minutes, no obligation.
Common questions
How deep are wells in Arundel?
The typical domestic well in Arundel is 310 feet deep, based on 520 wells reported to the state since 1970. One in ten is deeper than 505 feet. 98% are drilled into bedrock.
Is there arsenic in well water in Arundel?
Arsenic was detected in 100% of 4 public well samples in Arundel, and 100% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.
How high is radon in well water in Arundel?
The median radon level across 1 public samples in Arundel was 1,300 pCi/L, with a high of 1,300 pCi/L. New Hampshire recommends treatment above 2,000 pCi/L.
How often should I test a private well in Arundel?
Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.
Sources
- Maine DEP PFAS investigation: 144 samples in Arundel. PFAS results for private wells sampled by the Maine Department of Environmental Protection. Retrieved September 3, 2026.
- USGS Water Quality Portal: 35 samples in Arundel. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
- Maine Tracking Network private well summaries: summaries for 6 contaminants in Arundel, up to 89 wells each. Town summaries of private well tests run by the Maine Health and Environmental Testing Laboratory, published by Maine CDC through the Maine Tracking Network. Shares are against Maine's guideline for each analyte (arsenic 10 ug/L, uranium 30 ug/L, fluoride 2 mg/L, manganese 0.3 mg/L, nitrate 10 mg/L, nitrite 1 mg/L). Towns with too few tests are suppressed (NR). Only the share above the guideline and wells tested are published; no medians. Retrieved September 3, 2026.
- Maine Geological Survey well database: 547 well records in Arundel, 520 domestic. Well construction records reported to the Maine Geological Survey by licensed well drillers. Only aggregates are shown; owner names and addresses are never stored. Retrieved September 3, 2026.