Well Water Nerd

Well water in Tremont, Maine

1in17

Testing recommended

private wells tested in Tremont had arsenic above the Maine guideline (10 ug/L), according to Maine CDC.

56 private wells tested in state summaries. Data refreshed September 3, 2026.

Compiled by Nick at Well Water Nerd from public records. How these pages are built

What homeowner tests found

Maine Tracking Network private well summaries: private wells tested and reported to the state. Shares are against the level the state applies to each contaminant, named in the last column; several are stricter than EPA.

ContaminantAbove state levelWells testedMedian95th pctHighestState level
Manganese49300 ug/L
Arsenic5010 ug/L
Fluoride522 mg/L
Uranium4530 ug/L
Nitrate5610 mg/L
Nitrite561 mg/L

Closer than the town

See the sampled wells near your address

The same records, drawn around one point: which wells within a few miles were sampled and what they found, how deep the wells next to you were drilled, and any leaking tank or cleanup site within a mile.

Check my address

What this means

Among homeowners in Tremont who sent a sample to the state lab, the health-based limits most often exceeded were arsenic (6% of 50 wells), fluoride (6% of 52 wells), and uranium (2% of 45 wells). These are ordinary wells tested by their owners, so the shares are the best available picture of a typical well here, with one caveat: people test more often when they suspect a problem.

Manganese exceeds the state's advisory level in a sizable share of wells; this is mostly a taste, staining or diet issue rather than a toxicity one.

What to test for in Tremont

  1. 1
    Arsenic
    6% of 50 local wells tested were above the Maine guideline.
  2. 2
    Fluoride
    6% of 52 local wells tested were above the Maine guideline.
  3. 3
    Uranium
    2% of 45 local wells tested were above the Maine guideline.
  4. 4
    Coliform bacteria
    Recommended for every private well, every year.
  5. 5
    Nitrate
    Recommended for every private well, especially near farms or septic systems.
  6. 6
    Manganese
    14% of 49 local wells tested were above the Maine guideline.
  7. 7
    Volatile organic compounds (VOCs)
    2 leaking underground storage tank sites on record locally.
  8. 8
    PFAS
    1 unlined landfill on record locally.

Test your Tremont well for arsenic, fluoride and uranium

Certified lab analysis of your own tap water, bottles and prepaid return shipping included. The Essential well panel covers arsenic, uranium, nitrate, lead, copper, manganese, iron, sodium and bacteria; radon and PFAS are add-ons.

Order the Tap Score well water test kit, from $209Already tested? Upload the report

Just want bacteria checked first? Tap Score coliform and E. coli test, $99. Coliform and E. coli are the tests every well needs every year.

Want a quick look before paying for a lab? Home well water test strips on Amazon check hardness, iron, pH and nitrate in minutes. They are a screen, not a result: arsenic, bacteria, uranium and PFAS need a certified lab.

Affiliate links: the merchant pays us a commission and the price is the same for you. It does not change what the data above says. As an Amazon Associate we earn from qualifying purchases.

Where to get a well tested in Maine: certified labs, state programs and prices.

Already have results back? Get your lab report read against the Tremont numbers, $29. Every line explained, ranked by what matters, with the fix for each.

Wells in Tremont

331 domestic wells in Tremont are on record with the state since 1970. 100% are drilled into bedrock, and the typical well is 160 feet deep (one in ten goes past 325 feet).

In a typical Tremont well, bedrock starts about 5 feet down, the median yield is 6 gallons per minute, 14% of wells yield under 3 gallons per minute and usually need a storage tank.

Bedrock wells are where arsenic, uranium and radon come from: the water sits in fractures in granite and metamorphic rock and picks up whatever the rock carries. That is why testing for those three matters more here than in a dug or gravel well.

60
1970s
30
1980s
50
1990s
61
2000s
31
2010s
45
2020s

Official help in Maine

Two places to start that are not selling anything: the state program that answers private well questions, and its list of labs certified to run drinking water tests. A certified lab is the difference between a result you can act on and a number.

Contamination sources on record in Tremont

Maine DEP records 2 leaking underground storage tank sites and 1 unlined landfill in Tremont, among 7 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.

2
leaking underground storage tank sitesGasoline and heating oil that leaked from tanks move through groundwater as benzene, MTBE and other volatile organic compounds.
1
unlined landfillOlder unlined landfills are a leading source of PFAS, VOCs and metals in nearby wells.
4
other remediation projects

Treatment that fits the local profile

Arsenic

Point-of-use reverse osmosis; Adsorptive media (iron-based) whole-house; Anion exchange

Fluoride

Point-of-use reverse osmosis; Activated alumina; Distillation

Manganese

Oxidizing filter (greensand, birm) whole-house; Water softener (low levels); Point-of-use reverse osmosis

Systems we would look at first

Some links below are affiliate links. If you buy through one, the merchant pays us a commission at no extra cost to you. It does not change which products we list or what the data says.

For arsenic

Under-sink reverse osmosis system

under-sink or countertop, about $300

Look for NSF/ANSI 58 certification listing the contaminant you need removed.

For arsenic

Whole-house arsenic and uranium filter

whole-house, at the point of entry, about $2,500

Adsorptive iron-based media; sized to your well yield.

For arsenic

Aquasana SmartFlow reverse osmosis

under-sink or countertop, about $225

Certified to NSF/ANSI 58 and 53 to reduce arsenic (96%, pentavalent), fluoride (90%), lead (99%), nitrate, nitrite and PFOA/PFOS at the kitchen tap, with a remineralizer.

For manganese

Iron and manganese oxidizing filter

whole-house, at the point of entry, about $1,800

Air-injection or greensand media; fixes staining at the source.

Free, no obligation

Get on the list for a free in-home water test in Tremont

No water treatment company serves Tremont through Well Water Nerd yet. We are signing licensed companies on county by county: they test at your tap for free, walk you through the numbers, and quote treatment only if something needs fixing. Leave your details and you are first in line. Nothing is shared until a company joins for Tremont, and you get an email naming it first.

What are you worried about?

The test is free and there is no obligation. No company is named yet; your details stay with us until one joins for your area, and we log the time and address of this request.

Common questions

How deep are wells in Tremont?

The typical domestic well in Tremont is 160 feet deep, based on 331 wells reported to the state since 1970. One in ten is deeper than 325 feet. 100% are drilled into bedrock.

How often should I test a private well in Tremont?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Towns near Tremont

Closest first. Groundwater does not stop at a line on a map, so the next town over is a fair second opinion.

Want the numbers themselves? Download the Maine dataset as CSV, every county and town, with the sources named.

Sources

  • Maine Tracking Network private well summaries: summaries for 6 contaminants in Tremont, up to 56 wells each. Town summaries of private well tests run by the Maine Health and Environmental Testing Laboratory, published by Maine CDC through the Maine Tracking Network. Shares are against Maine's guideline for each analyte (arsenic 10 ug/L, uranium 30 ug/L, fluoride 2 mg/L, manganese 0.3 mg/L, nitrate 10 mg/L, nitrite 1 mg/L). Towns with too few tests are suppressed (NR). Only the share above the guideline and wells tested are published; no medians. Retrieved September 3, 2026.
  • Maine Geological Survey well database: 353 well records in Tremont, 331 domestic. Well construction records reported to the Maine Geological Survey by licensed well drillers. Only aggregates are shown; owner names and addresses are never stored. Retrieved September 3, 2026.
  • Maine DEP regulated sites: 7 regulated sites located in Tremont. Remediation sites, leaking underground storage tanks and closed municipal landfills from the Maine Department of Environmental Protection. Retrieved September 3, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.