Well Water Nerd

Well water in Industry, Maine

In Industry, 3% of 36 private wells tested had fluoride above the Maine guideline (2 mg/L), according to Maine CDC.

The strongest signal is arsenic: 9% of 22 local wells tested were above the Maine guideline, too few samples to carry the headline but first on the test list below.

36 private wells tested in state summaries; 23 test results across 12 contaminants from at least 3 wells, 1979 to 2023; PFHxS has the most at 3. Data refreshed September 3, 2026.

Compiled by Nick at Well Water Nerd from public records. How these pages are built

Maine DEP samples private wells near fields where sludge or septage was spread and near other known PFAS sources, and resamples detections. PFAS shares describe wells that were tested for a reason, not every well in the area.

What homeowner tests found

Maine Tracking Network private well summaries: private wells tested and reported to the state. Shares are against the level the state applies to each contaminant, named in the last column; several are stricter than EPA.

ContaminantAbove state levelWells testedMedian95th pctHighestState level
Arsenic2210 ug/L
Uranium2030 ug/L
Manganese22300 ug/L
Fluoride362 mg/L
Nitrate2910 mg/L
Nitrite291 mg/L

Closer than the town

See the sampled wells near your address

The same records, drawn around one point: which wells within a few miles were sampled and what they found, how deep the wells next to you were drilled, and any leaking tank or cleanup site within a mile.

Check my address

What this means

Among homeowners in Industry who sent a sample to the state lab, the health-based limits most often exceeded were arsenic (9% of 22 wells), uranium (5% of 20 wells), and fluoride (3% of 36 wells). These are ordinary wells tested by their owners, so the shares are the best available picture of a typical well here, with one caveat: people test more often when they suspect a problem.

What to test for in Industry

  1. 1
    Arsenic
    9% of 22 local wells tested were above the Maine guideline.
  2. 2
    Uranium
    5% of 20 local wells tested were above the Maine guideline.
  3. 3
    Fluoride
    3% of 36 local wells tested were above the Maine guideline.
  4. 4
    Coliform bacteria
    Recommended for every private well, every year.
  5. 5
    Nitrate
    Recommended for every private well, especially near farms or septic systems.
  6. 6
    Manganese
    5% of 22 local wells tested were above the Maine guideline.
  7. 7
    Iron
    Detected in 100% of local samples.
  8. 8
    Chloride
    Detected in 100% of local samples.

Test your Industry well for arsenic, uranium and fluoride

Certified lab analysis of your own tap water, bottles and prepaid return shipping included. The Essential well panel covers arsenic, uranium, nitrate, lead, copper, manganese, iron, sodium and bacteria; radon and PFAS are add-ons.

Order the Tap Score well water test kit, from $209Already tested? Upload the report

Just want bacteria checked first? Tap Score coliform and E. coli test, $99. Coliform and E. coli are the tests every well needs every year.

Want a quick look before paying for a lab? Home well water test strips on Amazon check hardness, iron, pH and nitrate in minutes. They are a screen, not a result: arsenic, bacteria, uranium and PFAS need a certified lab.

Affiliate links: the merchant pays us a commission and the price is the same for you. It does not change what the data above says. As an Amazon Associate we earn from qualifying purchases.

Where to get a well tested in Maine: certified labs, state programs and prices.

Already have results back? Get your lab report read against the Industry numbers, $29. Every line explained, ranked by what matters, with the fix for each.

Wells in Industry

111 domestic wells in Industry are on record with the state since 1972. 99% are drilled into bedrock, and the typical well is 180 feet deep (one in ten goes past 326 feet).

In a typical Industry well, bedrock starts about 22 feet down, the median yield is 8 gallons per minute, 23% of wells yield under 3 gallons per minute and usually need a storage tank.

Bedrock wells are where arsenic, uranium and radon come from: the water sits in fractures in granite and metamorphic rock and picks up whatever the rock carries. That is why testing for those three matters more here than in a dug or gravel well.

15
1970s
10
1980s
9
1990s
27
2000s
21
2010s
22
2020s

The rock under Industry

Not a principal aquifer

The USGS map places this area outside any principal aquifer, which usually means wells here draw from fractured bedrock or thin local deposits rather than a large regional aquifer. Bedrock wells of that kind are where arsenic, radon and uranium turn up, and yields vary from well to well.

Classification from the USGS Principal Aquifers of the United States (national map, 2003 edition, GIS release 2015), read at the town centroid. A single well can sit in a different unit, especially near a boundary.

Official help in Maine

Two places to start that are not selling anything: the state program that answers private well questions, and its list of labs certified to run drinking water tests. A certified lab is the difference between a result you can act on and a number.

Treatment that fits the local profile

Arsenic

Point-of-use reverse osmosis; Adsorptive media (iron-based) whole-house; Anion exchange

Uranium

Point-of-use reverse osmosis; Anion exchange; Whole-house anion exchange

Manganese

Oxidizing filter (greensand, birm) whole-house; Water softener (low levels); Point-of-use reverse osmosis

Iron

Oxidizing filter whole-house; Water softener (low levels); Aeration plus filtration

Systems we would look at first

Some links below are affiliate links. If you buy through one, the merchant pays us a commission at no extra cost to you. It does not change which products we list or what the data says.

For arsenic

Under-sink reverse osmosis system

under-sink or countertop, about $300

Look for NSF/ANSI 58 certification listing the contaminant you need removed.

For arsenic

Whole-house arsenic and uranium filter

whole-house, at the point of entry, about $2,500

Adsorptive iron-based media; sized to your well yield.

For arsenic

Aquasana SmartFlow reverse osmosis

under-sink or countertop, about $225

Certified to NSF/ANSI 58 and 53 to reduce arsenic (96%, pentavalent), fluoride (90%), lead (99%), nitrate, nitrite and PFOA/PFOS at the kitchen tap, with a remineralizer.

For manganese

Iron and manganese oxidizing filter

whole-house, at the point of entry, about $1,800

Air-injection or greensand media; fixes staining at the source.

Free, no obligation

Get on the list for a free in-home water test in Industry

No water treatment company serves Industry through Well Water Nerd yet. We are signing licensed companies on county by county: they test at your tap for free, walk you through the numbers, and quote treatment only if something needs fixing. Leave your details and you are first in line. Nothing is shared until a company joins for Industry, and you get an email naming it first.

What are you worried about?

The test is free and there is no obligation. No company is named yet; your details stay with us until one joins for your area, and we log the time and address of this request.

Common questions

How deep are wells in Industry?

The typical domestic well in Industry is 180 feet deep, based on 111 wells reported to the state since 1972. One in ten is deeper than 326 feet. 99% are drilled into bedrock.

How often should I test a private well in Industry?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Towns near Industry

Closest first. Groundwater does not stop at a line on a map, so the next town over is a fair second opinion.

Want the numbers themselves? Download the Maine dataset as CSV, every county and town, with the sources named.

Sources

  • Maine DEP PFAS investigation: 12 samples in Industry. PFAS results for private wells sampled by the Maine Department of Environmental Protection. Retrieved September 3, 2026.
  • USGS Water Quality Portal: 11 samples in Industry. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
  • Maine Tracking Network private well summaries: summaries for 6 contaminants in Industry, up to 36 wells each. Town summaries of private well tests run by the Maine Health and Environmental Testing Laboratory, published by Maine CDC through the Maine Tracking Network. Shares are against Maine's guideline for each analyte (arsenic 10 ug/L, uranium 30 ug/L, fluoride 2 mg/L, manganese 0.3 mg/L, nitrate 10 mg/L, nitrite 1 mg/L). Towns with too few tests are suppressed (NR). Only the share above the guideline and wells tested are published; no medians. Retrieved September 3, 2026.
  • Maine Geological Survey well database: 112 well records in Industry, 111 domestic. Well construction records reported to the Maine Geological Survey by licensed well drillers. Only aggregates are shown; owner names and addresses are never stored. Retrieved September 3, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.