Well water in New Gloucester, Maine
In New Gloucester, 34% of 179 private wells tested had uranium above the Maine guideline (30 ug/L), according to Maine CDC.
233 private wells tested in state summaries; 25 individual samples from 25 wells, 1982 to 2025. Data refreshed September 3, 2026.
Maine DEP samples private wells near fields where sludge or septage was spread and near other known PFAS sources, and resamples detections. PFAS shares describe wells that were tested for a reason, not every well in the area. In that targeted sampling, 4% of 25 PFOA results in New Gloucester were above the EPA limit of 4 ng/L. In that targeted sampling, 4% of 25 PFOS results in New Gloucester were above the EPA limit of 4 ng/L.
What homeowner tests found
Maine Tracking Network private well summaries: private wells tested and reported to the state. Shares are against the level the state applies to each contaminant, named in the last column; several are stricter than EPA.
What individual samples found
Each row summarizes every public sample for that contaminant inside New Gloucester. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.
| Contaminant | Samples | Detected | Above limit | Median | Highest | Limit | |
|---|---|---|---|---|---|---|---|
| PFOA 2022 to 2025 | 25 | 52% | 4% | 0.238 | 6.76 | 4 ng/L EPA limit | |
| PFOS 2022 to 2025 | 25 | 36% | 4% | 0 | 4.11 | 4 ng/L EPA limit | |
| PFHxS 2022 to 2025 | 25 | 28% | 0% | 0 | 3.03 | 10 ng/L EPA limit | |
| PFNA 2022 to 2025 | 25 | 4% | 0% | 0 | 0.508 | 10 ng/L EPA limit |
Sampled fewer than 10 times, too few to summarize: Uranium (1), Nitrate (2), Radium (226 + 228) (2), Copper (1), Arsenic (1), Chloride (2).
Get the free New Gloucester well report
One email with the numbers above, what they mean for a home in New Gloucester, exactly which tests to order, and what treatment fits the local profile. No spam, unsubscribe in one click.
What this means
Among homeowners in New Gloucester who sent a sample to the state lab, the health-based limits most often exceeded were uranium (34% of 179 wells), arsenic (11% of 197 wells), and nitrate (<1% of 197 wells). These are ordinary wells tested by their owners, so the shares are the best available picture of a typical well here, with one caveat: people test more often when they suspect a problem.
What to test for in New Gloucester
- Volatile organic compounds (VOCs)1 leaking underground storage tank site on record locally.
- PFAS2 unlined landfills on record locally.
- Uranium34% of 179 local wells tested were above the Maine guideline.
- Arsenic11% of 197 local wells tested were above the Maine guideline.
- PFOA4% of 25 local samples were above the limit.
- PFOS4% of 25 local samples were above the limit.
- Manganese<1% of 152 local wells tested were above the Maine guideline.
- Nitrate<1% of 197 local wells tested were above the Maine guideline.
- Coliform bacteriaRecommended for every private well, every year.
- CopperDetected in 100% of local samples.
Wells in New Gloucester
632 domestic wells in New Gloucester are on record with the state since 1970. 97% are drilled into bedrock, and the typical well is 300 feet deep (one in ten goes past 520 feet).
In a typical New Gloucester well, bedrock starts about 20 feet down, the median yield is 5 gallons per minute, 27% of wells yield under 3 gallons per minute and usually need a storage tank.
Bedrock wells are where arsenic, uranium and radon come from: the water sits in fractures in granite and metamorphic rock and picks up whatever the rock carries. That is why testing for those three matters more here than in a dug or gravel well.
Contamination sources on record in New Gloucester
Maine DEP records 1 leaking underground storage tank site and 2 unlined landfills in New Gloucester, among 9 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.
- 1
- leaking underground storage tank siteGasoline and heating oil that leaked from tanks move through groundwater as benzene, MTBE and other volatile organic compounds.
- 2
- unlined landfillsOlder unlined landfills are a leading source of PFAS, VOCs and metals in nearby wells.
- 6
- other remediation projects
Treatment that fits the local profile
- Uranium
- Point-of-use reverse osmosis; Anion exchange; Whole-house anion exchange
- Arsenic
- Point-of-use reverse osmosis; Adsorptive media (iron-based) whole-house; Anion exchange
- PFOA
- Granular activated carbon whole-house; Point-of-use reverse osmosis; Anion exchange
- PFOS
- Granular activated carbon whole-house; Point-of-use reverse osmosis; Anion exchange
- Copper
- Neutralizing filter to raise pH; Point-of-use reverse osmosis
- Chloride
- Point-of-use reverse osmosis; Distillation
Book a free water test in New Gloucester
A licensed local water treatment company tests your tap water in your home, walks you through the numbers, and quotes treatment only if something needs fixing. Free, about 30 minutes, no obligation.
Common questions
How deep are wells in New Gloucester?
The typical domestic well in New Gloucester is 300 feet deep, based on 632 wells reported to the state since 1970. One in ten is deeper than 520 feet. 97% are drilled into bedrock.
Is there arsenic in well water in New Gloucester?
Arsenic was detected in 100% of 1 public well samples in New Gloucester, and 0% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.
How often should I test a private well in New Gloucester?
Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.
Sources
- Maine DEP PFAS investigation: 100 samples in New Gloucester. PFAS results for private wells sampled by the Maine Department of Environmental Protection. Retrieved September 3, 2026.
- USGS Water Quality Portal: 9 samples in New Gloucester. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
- Maine Tracking Network private well summaries: summaries for 6 contaminants in New Gloucester, up to 233 wells each. Town summaries of private well tests run by the Maine Health and Environmental Testing Laboratory, published by Maine CDC through the Maine Tracking Network. Shares are against Maine's guideline for each analyte (arsenic 10 ug/L, uranium 30 ug/L, fluoride 2 mg/L, manganese 0.3 mg/L, nitrate 10 mg/L, nitrite 1 mg/L). Towns with too few tests are suppressed (NR). Only the share above the guideline and wells tested are published; no medians. Retrieved September 3, 2026.
- Maine Geological Survey well database: 651 well records in New Gloucester, 632 domestic. Well construction records reported to the Maine Geological Survey by licensed well drillers. Only aggregates are shown; owner names and addresses are never stored. Retrieved September 3, 2026.
- Maine DEP regulated sites: 9 regulated sites located in New Gloucester. Remediation sites, leaking underground storage tanks and closed municipal landfills from the Maine Department of Environmental Protection. Retrieved September 3, 2026.
Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.