Well Water Nerd

Well water in Wyandotte County, Kansas

1in13

Testing recommended

tested well samples in Wyandotte County exceeded the EPA limit for nitrate (10 mg/L), based on public data from USGS Water Quality Portal.

The strongest signal is arsenic: 20% of 15 local samples were above the limit, too few samples to carry the headline but first on the test list below.

883 test results across 13 contaminants from at least 122 wells, 1943 to 2018; fluoride has the most at 164. Data refreshed September 3, 2026.

Compiled by Nick at Well Water Nerd from public records. How these pages are built

What individual samples found

Each row summarizes every public sample for that contaminant inside Wyandotte County. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.

ContaminantAbove limitSamplesDetectedMedianHighestLimit
Arsenic
1980 to 2018
1580%34610 ug/L
EPA limit
Nitrate
1943 to 2018
16394%0.823010 mg/L
EPA limit
Fluoride
1943 to 2018
16499%0.22.54 mg/L
EPA limit
Lead
1980 to 2018
1553%00.32915 ug/L
EPA limit
Copper
1976 to 2018
1164%0.0050.021.3 mg/L
EPA limit
Chloride
1943 to 2018
no limit150100%514,000250 mg/L
nuisance level
Iron
1943 to 2018
no limit14899%5,46038,000300 ug/L
nuisance level
Sodium
1943 to 2018
no limit139100%37.32,50020 mg/L
health guideline
Manganese
1957 to 2018
no limit7297%4553,000300 ug/L
health guideline

Sampled fewer than 10 times, too few to summarize: Radium (226 + 228) (3), E. coli (1), Uranium (1), Radon (1).

Closer than the county

See the sampled wells near your address

The same records, drawn around one point: which wells within a few miles were sampled and what they found, how deep the wells next to you were drilled, and any leaking tank or cleanup site within a mile.

Check my address

What this means

The contaminants most often above their limit here are arsenic (20% of 15 samples) and nitrate (8% of 163 samples). A well next door can differ sharply from yours because bedrock fractures, well depth and plumbing all matter, so these rates describe the area, not your tap.

Chloride, Iron, and Manganese are widespread in local groundwater. They are mainly a staining and taste problem, but high manganese also carries a health advisory for infants.

What to test for in Wyandotte County

  1. 1
    Arsenic
    20% of 15 local samples were above the limit.
  2. 2
    Nitrate
    8% of 163 local samples were above the limit.
  3. 3
    Coliform bacteria
    Recommended for every private well, every year.
  4. 4
    Radon
    Median local reading is 290 pCi/L.
  5. 5
    Chloride
    Detected in 100% of local samples.
  6. 6
    Fluoride
    Detected in 99% of local samples.
  7. 7
    Iron
    Detected in 99% of local samples.
  8. 8
    Volatile organic compounds (VOCs)
    723 leaking underground storage tank sites on record locally.
  9. 9
    Metals panel
    18 hazardous waste sites on record locally.

Test your Wyandotte County well for arsenic, nitrate and coliform bacteria

Certified lab analysis of your own tap water, bottles and prepaid return shipping included. The Essential well panel covers arsenic, uranium, nitrate, lead, copper, manganese, iron, sodium and bacteria; radon and PFAS are add-ons.

Order the Tap Score well water test kit, from $209Already tested? Upload the report

Just want bacteria checked first? Tap Score coliform and E. coli test, $99. Coliform and E. coli are the tests every well needs every year.

Want a quick look before paying for a lab? Home well water test strips on Amazon check hardness, iron, pH and nitrate in minutes. They are a screen, not a result: arsenic, bacteria, uranium and PFAS need a certified lab.

Affiliate links: the merchant pays us a commission and the price is the same for you. It does not change what the data above says. As an Amazon Associate we earn from qualifying purchases.

Where to get a well tested in Kansas: certified labs, state programs and prices.

Already have results back? Get your lab report read against the Wyandotte County numbers, $29. Every line explained, ranked by what matters, with the fix for each.

The rock under Wyandotte County

Not a principal aquifer

The USGS map places this area outside any principal aquifer, which usually means wells here draw from fractured bedrock or thin local deposits rather than a large regional aquifer. Bedrock wells of that kind are where arsenic, radon and uranium turn up, and yields vary from well to well.

Classification from the USGS Principal Aquifers of the United States (national map, 2003 edition, GIS release 2015), read at the county centroid. A single well can sit in a different unit, especially near a boundary.

Contamination sources on record in Wyandotte County

KDHE records 723 leaking underground storage tank sites and 18 hazardous waste sites in Wyandotte County, among 1,003 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.

723
leaking underground storage tank sitesGasoline and heating oil that leaked from tanks move through groundwater as benzene, MTBE and other volatile organic compounds.
18
hazardous waste sitesSolvents, degreasers and metals from industrial sites can travel far in fractured bedrock.
220
other remediation projects
42
other solid waste facilities

Treatment that fits the local profile

Arsenic

Point-of-use reverse osmosis; Adsorptive media (iron-based) whole-house; Anion exchange

Nitrate

Point-of-use reverse osmosis; Anion exchange; Distillation

Chloride

Point-of-use reverse osmosis; Distillation

Iron

Oxidizing filter whole-house; Water softener (low levels); Aeration plus filtration

Manganese

Oxidizing filter (greensand, birm) whole-house; Water softener (low levels); Point-of-use reverse osmosis

Systems we would look at first

Some links below are affiliate links. If you buy through one, the merchant pays us a commission at no extra cost to you. It does not change which products we list or what the data says.

For arsenic

Under-sink reverse osmosis system

under-sink or countertop, about $300

Look for NSF/ANSI 58 certification listing the contaminant you need removed.

For arsenic

Whole-house arsenic and uranium filter

whole-house, at the point of entry, about $2,500

Adsorptive iron-based media; sized to your well yield.

For arsenic

Aquasana SmartFlow reverse osmosis

under-sink or countertop, about $225

Certified to NSF/ANSI 58 and 53 to reduce arsenic (96%, pentavalent), fluoride (90%), lead (99%), nitrate, nitrite and PFOA/PFOS at the kitchen tap, with a remineralizer.

For iron

Iron and manganese oxidizing filter

whole-house, at the point of entry, about $1,800

Air-injection or greensand media; fixes staining at the source.

Free, no obligation

Get on the list for a free in-home water test in Wyandotte County

No water treatment company serves Wyandotte County through Well Water Nerd yet. We are signing licensed companies on county by county: they test at your tap for free, walk you through the numbers, and quote treatment only if something needs fixing. Leave your details and you are first in line. Nothing is shared until a company joins for Wyandotte County, and you get an email naming it first.

What are you worried about?

The test is free and there is no obligation. No company is named yet; your details stay with us until one joins for your area, and we log the time and address of this request.

Common questions

Is there arsenic in well water in Wyandotte County?

Arsenic was detected in 80% of 15 public well samples in Wyandotte County, and 20% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.

How often should I test a private well in Wyandotte County?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Counties near Wyandotte County

Closest first. Groundwater does not stop at a line on a map, so the next county over is a fair second opinion.

Want the numbers themselves? Download the Kansas dataset as CSV, every county and town, with the sources named.

Sources

  • USGS Water Quality Portal: 883 samples in Wyandotte County. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
  • KDHE regulated sites: 1,003 regulated sites located in Wyandotte County. Identified contaminated sites, leaking underground storage tank facilities and solid waste facilities from the Kansas Department of Health and Environment. Retrieved September 9, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.