Well Water Nerd

Well water in Illinois

1in6

Testing recommended

tested well samples in Illinois exceeded the EPA limit for PFOA (4 ng/L), based on public data from USGS Water Quality Portal.

60,373 test results across 15 contaminants from at least 6,644 wells, 1901 to 2026; nitrate has the most at 10,010. Data refreshed September 15, 2026.

Compiled by Nick at Well Water Nerd from public records. How these pages are built

An estimated 1,151,113 people in Illinois get their drinking water from a private well, per USGS 2015 county water use.

Separately, the USGS national arsenic model estimates that 6% of the 1,151,113 people on private wells in Illinois draw water above 10 ug/L (the model's range is 5% to 7%), from geology and well depth rather than local tests.

What individual samples found

Each row summarizes every public sample for that contaminant inside Illinois. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.

ContaminantAbove limitSamplesDetectedMedianHighestLimit
PFOA
2019 to 2021
3037%0174 ng/L
EPA limit
Radium (226 + 228)
1999 to 2019
35086%0.72225 pCi/L
EPA limit
Arsenic
1973 to 2023
5,09845%012810 ug/L
EPA limit
Nitrate
1901 to 2026
10,01063%0.11,17010 mg/L
EPA limit
E. coli
2007 to 2019
754%070 MPN/100mL
EPA limit
PFOS
2019 to 2021
3013%0164 ng/L
EPA limit
Lead
1971 to 2023
5,51721%02,00015 ug/L
EPA limit
Fluoride
1931 to 2025
6,15197%0.415.54 mg/L
EPA limit
Copper
1971 to 2023
5,52334%0131.3 mg/L
EPA limit
Uranium
1979 to 2023
61260%0.0511730 ug/L
EPA limit
Iron
1901 to 2025
no limit6,92589%260587,000300 ug/L
nuisance level
Chloride
1901 to 2025
no limit6,73797%1637,000250 mg/L
nuisance level
Manganese
1914 to 2025
no limit6,62486%2036,000300 ug/L
health guideline
Sodium
1901 to 2025
no limit6,462100%32.715,00020 mg/L
health guideline
Radon
1996 to 2019
no limit22997%21015,4002,000 pCi/L
health guideline

Over time

Share of samples above the limit by period. A cell needs ten samples to show; a comparison needs twenty in each period. Later periods sample fewer wells, and often the ones already known to have a problem.

Contaminantbefore 20002000s2010s2020s
Nitrate8%8,254 samples11%1,085 samples12%553 samples12%118 samples
Fluoride<1%5,622 samples0%160 samples<1%269 samples0%100 samples
Copper<1%5,091 samples0%179 samples0%184 samples0%69 samples
Lead2%5,084 samples0%180 samples<1%184 samples0%69 samples
Arsenic9%4,665 samples18%180 samples16%184 samples17%69 samples
Uranium0%183 samples0%176 samples0%184 samples0%69 samples

Nitrate, fluoride, copper, lead, arsenic, uranium have held within a few points between the two most recent periods with enough samples.

What this means

The contaminants most often above their limit here are pfoa (17% of 30 samples), radium (226 + 228) (12% of 350 samples), and arsenic (10% of 5,098 samples). A well next door can differ sharply from yours because bedrock fractures, well depth and plumbing all matter, so these rates describe the area, not your tap.

Iron, Chloride, and Manganese are widespread in local groundwater. They are mainly a staining and taste problem, but high manganese also carries a health advisory for infants.

What to test for in Illinois

  1. 1
    PFOA
    17% of 30 local samples were above the limit.
  2. 2
    Radium (226 + 228)
    12% of 350 local samples were above the limit.
  3. 3
    Arsenic
    10% of 5,098 local samples were above the limit.
  4. 4
    Nitrate
    9% of 10,010 local samples were above the limit.
  5. 5
    E. coli
    4% of 75 local samples were above the limit.
  6. 6
    PFOS
    3% of 30 local samples were above the limit.
  7. 7
    Lead
    2% of 5,517 local samples were above the limit.

Test your Illinois well for PFOA, radium (226 + 228) and arsenic

Certified lab analysis of your own tap water, bottles and prepaid return shipping included. The Essential well panel covers arsenic, uranium, nitrate, lead, copper, manganese, iron, sodium and bacteria; radon and PFAS are add-ons.

Order the Tap Score well water test kit, from $209Already tested? Upload the report

Just want bacteria checked first? Tap Score coliform and E. coli test, $99. Coliform and E. coli are the tests every well needs every year.

Want a quick look before paying for a lab? Home well water test strips on Amazon check hardness, iron, pH and nitrate in minutes. They are a screen, not a result: arsenic, bacteria, uranium and PFAS need a certified lab.

Affiliate links: the merchant pays us a commission and the price is the same for you. It does not change what the data above says. As an Amazon Associate we earn from qualifying purchases.

Where to get a well tested in Illinois: certified labs, state programs and prices.

Already have results back? Get your lab report read against the Illinois numbers, $29. Every line explained, ranked by what matters, with the fix for each.

Free, one email

Send me the Illinois report

The numbers above, which tests to order and where, and the treatment that fits the local profile, in one email.

The rock under Illinois

Not a principal aquifer

The USGS map places this area outside any principal aquifer, which usually means wells here draw from fractured bedrock or thin local deposits rather than a large regional aquifer. Bedrock wells of that kind are where arsenic, radon and uranium turn up, and yields vary from well to well.

Classification from the USGS Principal Aquifers of the United States (national map, 2003 edition, GIS release 2015), read at the state centroid. A single well can sit in a different unit, especially near a boundary.

Official help in Illinois

Two places to start that are not selling anything: the state program that answers private well questions, and its list of labs certified to run drinking water tests. A certified lab is the difference between a result you can act on and a number.

Treatment that fits the local profile

PFOA

Granular activated carbon whole-house; Point-of-use reverse osmosis; Anion exchange

Radium (226 + 228)

Water softener (cation exchange); Point-of-use reverse osmosis

Arsenic

Point-of-use reverse osmosis; Adsorptive media (iron-based) whole-house; Anion exchange

Nitrate

Point-of-use reverse osmosis; Anion exchange; Distillation

E. coli

Shock chlorination and fix the well cap or casing; UV disinfection whole-house; Chlorination system

Systems we would look at first

Some links below are affiliate links. If you buy through one, the merchant pays us a commission at no extra cost to you. It does not change which products we list or what the data says.

For PFOA

Under-sink reverse osmosis system

under-sink or countertop, about $300

Look for NSF/ANSI 58 certification listing the contaminant you need removed.

For PFOA

Whole-house PFAS carbon system

whole-house, at the point of entry, about $3,000

Granular activated carbon certified to NSF/ANSI 53 for PFOA and PFOS; replace media on schedule.

For PFOA

Aquasana SmartFlow reverse osmosis

under-sink or countertop, about $225

Certified to NSF/ANSI 58 and 53 to reduce arsenic (96%, pentavalent), fluoride (90%), lead (99%), nitrate, nitrite and PFOA/PFOS at the kitchen tap, with a remineralizer.

For arsenic

Whole-house arsenic and uranium filter

whole-house, at the point of entry, about $2,500

Adsorptive iron-based media; sized to your well yield.

For E. coli

UV disinfection system

whole-house, at the point of entry, about $900

Fix the well cap and casing first; UV keeps bacteria from returning.

For E. coli

Aquasana Rhino Well Water with UV

whole-house, at the point of entry, about $2,871

Whole-house system built for wells: sediment pre-filter, KDF and carbon, and a UV lamp rated to kill 99.99% of bacteria and viruses. It does not remove arsenic, nitrate, uranium or radon.

Common questions

Is there arsenic in well water in Illinois?

Arsenic was detected in 45% of 5,098 public well samples in Illinois, and 10% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.

How high is radon in well water in Illinois?

The median radon level across 229 public samples in Illinois was 210 pCi/L, with a high of 15,400 pCi/L. New Hampshire recommends treatment above 2,000 pCi/L.

How often should I test a private well in Illinois?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Counties in Illinois

Want the numbers themselves? Download the Illinois dataset as CSV, every county and town, with the sources named.

Sources

  • USGS Water Quality Portal: 60,373 samples in Illinois. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
  • USGS national arsenic model (Ayotte 2017): estimated share of 1,151,113 people on private wells in Illinois above 10 ug/L of arsenic, from geology, well depth and land use. County estimates of domestic well users with arsenic above 10 ug/L from the USGS national logistic regression model (Ayotte, Medalie and Qi, 2017), with private well population from the USGS 2015 county water-use compilation (Dieter and others, 2018). Retrieved September 15, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.