Well water in Hardee County, Florida
In Hardee County, 4% of 45 tested well samples exceeded the EPA limit for lead (15 ug/L), based on public data from USGS Water Quality Portal.
2,755 test results across 9 contaminants from at least 108 wells, 1951 to 2025; fluoride has the most at 721. Data refreshed September 15, 2026.
Compiled by Nick at Well Water Nerd from public records. How these pages are built
An estimated 11,651 people in Hardee County get their drinking water from a private well, per USGS 2015 county water use. That is about 42% of residents.
Separately, the USGS national arsenic model estimates that 5% of the 11,651 people on private wells in Hardee County draw water above 10 ug/L (the model's range is 3% to 8%), from geology and well depth rather than local tests.
What individual samples found
Each row summarizes every public sample for that contaminant inside Hardee County. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.
| Contaminant | Above limit | Samples | Detected | Median | Highest | Limit |
|---|---|---|---|---|---|---|
| Lead 1983 to 2024 | 45 | 96% | 0.2 | 36.2 | 15 ug/L EPA limit | |
| Fluoride 1951 to 2025 | 721 | 99% | 0.69 | 2.8 | 4 mg/L EPA limit | |
| Nitrate 1962 to 1994 | 83 | 70% | 0 | 1.4 | 10 mg/L EPA limit | |
| Arsenic 1972 to 2024 | 46 | 98% | 0.29 | 3.75 | 10 ug/L EPA limit | |
| Copper 1983 to 2024 | 45 | 100% | 0 | 0.09 | 1.3 mg/L EPA limit | |
| Radium (226 + 228) 1974 to 1988 | 10 | 60% | 0.145 | 1.9 | 5 pCi/L EPA limit | |
| Sodium 1962 to 2025 | no limit | 692 | 100% | 11.7 | 67.7 | 20 mg/L health guideline |
| Iron 1962 to 2025 | no limit | 573 | 100% | 8.5 | 10,000 | 300 ug/L nuisance level |
| Manganese 1986 to 2025 | no limit | 540 | 99% | 0.46 | 120 | 300 ug/L health guideline |
Over time
Share of samples above the limit by period. A cell needs ten samples to show; a comparison needs twenty in each period. Later periods sample fewer wells, and often the ones already known to have a problem.
| Contaminant | before 2000 | 2000s | 2010s | 2020s |
|---|---|---|---|---|
| Fluoride | 0%118 samples | n/a | 0%309 samples | 0%294 samples |
| Lead | n/a | n/a | 0%18 samples | 8%24 samples |
| Arsenic | n/a | n/a | 0%18 samples | 0%24 samples |
| Copper | n/a | n/a | 0%18 samples | 0%24 samples |
Fluoride has held within a few points between the two most recent periods with enough samples.
Closer than the county
See the sampled wells near your address
The same records, drawn around one point: which wells within a few miles were sampled and what they found, how deep the wells next to you were drilled, and any leaking tank or cleanup site within a mile.
Check my addressWhat this means
The contaminants most often above their limit here are lead (4% of 45 samples). A well next door can differ sharply from yours because bedrock fractures, well depth and plumbing all matter, so these rates describe the area, not your tap.
Iron and Manganese are widespread in local groundwater. They are mainly a staining and taste problem, but high manganese also carries a health advisory for infants.
What to test for in Hardee County
- 1Lead4% of 45 local samples were above the limit.
- 2Coliform bacteriaRecommended for every private well, every year.
- 3NitrateRecommended for every private well, especially near farms or septic systems.
- 4CopperDetected in 100% of local samples.
- 5IronDetected in 100% of local samples.
- 6ManganeseDetected in 99% of local samples.
- 7FluorideDetected in 99% of local samples.
- 8Volatile organic compounds (VOCs)124 leaking underground storage tank sites on record locally.
Test your Hardee County well for lead, coliform bacteria and nitrate
Certified lab analysis of your own tap water, bottles and prepaid return shipping included. The Essential well panel covers arsenic, uranium, nitrate, lead, copper, manganese, iron, sodium and bacteria; radon and PFAS are add-ons.
Order the Tap Score well water test kit, from $209Already tested? Upload the report
Just want bacteria checked first? Tap Score coliform and E. coli test, $99. Coliform and E. coli are the tests every well needs every year.
Want a quick look before paying for a lab? Home well water test strips on Amazon check hardness, iron, pH and nitrate in minutes. They are a screen, not a result: arsenic, bacteria, uranium and PFAS need a certified lab.
Affiliate links: the merchant pays us a commission and the price is the same for you. It does not change what the data above says. As an Amazon Associate we earn from qualifying purchases.
Where to get a well tested in Florida: certified labs, state programs and prices.
Already have results back? Get your lab report read against the Hardee County numbers, $29. Every line explained, ranked by what matters, with the fix for each.
The rock under Hardee County
Surficial aquifer system
Unconsolidated sand and gravel. Wells in sand and gravel are usually shallow and productive, and they recharge quickly from the surface. That makes them the most exposed to nitrate, bacteria and anything spilled nearby, and the least likely to carry arsenic or radon from the rock.
Classification from the USGS Principal Aquifers of the United States (national map, 2003 edition, GIS release 2015), read at the county centroid. A single well can sit in a different unit, especially near a boundary.
Official help in Florida
Two places to start that are not selling anything: the state program that answers private well questions, and its list of labs certified to run drinking water tests. A certified lab is the difference between a result you can act on and a number.
- Private Well Water Testing, Florida Department of Health
- NELAP Certified Laboratory Search, Florida DEP
Contamination sources on record in Hardee County
FDEP records 124 leaking underground storage tank sites in Hardee County, among 150 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.
- 124
- leaking underground storage tank sitesGasoline and heating oil that leaked from tanks move through groundwater as benzene, MTBE and other volatile organic compounds.
- 26
- other remediation projects
Treatment that fits the local profile
Lead
Point-of-use reverse osmosis; Certified lead-removal carbon filter; Neutralizing filter to raise pH and stop leaching
Iron
Oxidizing filter whole-house; Water softener (low levels); Aeration plus filtration
Systems we would look at first
Some links below are affiliate links. If you buy through one, the merchant pays us a commission at no extra cost to you. It does not change which products we list or what the data says.
For lead
Under-sink reverse osmosis system
under-sink or countertop, about $300
Look for NSF/ANSI 58 certification listing the contaminant you need removed.
For lead
Acid neutralizing filter
whole-house, at the point of entry, about $1,200
Raises pH so plumbing stops leaching lead and copper.
For lead
Aquasana SmartFlow reverse osmosis
under-sink or countertop, about $225
Certified to NSF/ANSI 58 and 53 to reduce arsenic (96%, pentavalent), fluoride (90%), lead (99%), nitrate, nitrite and PFOA/PFOS at the kitchen tap, with a remineralizer.
For iron
Iron and manganese oxidizing filter
whole-house, at the point of entry, about $1,800
Air-injection or greensand media; fixes staining at the source.
Free, no obligation
Get on the list for a free in-home water test in Hardee County
No water treatment company serves Hardee County through Well Water Nerd yet. We are signing licensed companies on county by county: they test at your tap for free, walk you through the numbers, and quote treatment only if something needs fixing. Leave your details and you are first in line. Nothing is shared until a company joins for Hardee County, and you get an email naming it first.
Common questions
Is there arsenic in well water in Hardee County?
Arsenic was detected in 98% of 46 public well samples in Hardee County, and 0% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.
How often should I test a private well in Hardee County?
Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.
Counties near Hardee County
Closest first. Groundwater does not stop at a line on a map, so the next county over is a fair second opinion.
Want the numbers themselves? Download the Florida dataset as CSV, every county and town, with the sources named.
Sources
- USGS Water Quality Portal: 2,755 samples in Hardee County. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
- USGS national arsenic model (Ayotte 2017): estimated share of 11,651 people on private wells in Hardee County above 10 ug/L of arsenic, from geology, well depth and land use. County estimates of domestic well users with arsenic above 10 ug/L from the USGS national logistic regression model (Ayotte, Medalie and Qi, 2017), with private well population from the USGS 2015 county water-use compilation (Dieter and others, 2018). Retrieved September 15, 2026.
- FDEP regulated sites: 150 regulated sites located in Hardee County. Petroleum contamination discharges and cleanup sites from the Florida Department of Environmental Protection. Retrieved September 17, 2026.
Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.