Well Water Nerd

Well water in South Windsor, Connecticut

1in4

Testing strongly recommended

tested well samples in South Windsor exceeded the EPA limit for nitrate (10 mg/L), based on public data from USGS Water Quality Portal and Connecticut DPH and USGS arsenic and uranium survey.

250 test results across 11 contaminants from at least 24 wells, 1953 to 2017; nitrate has the most at 38. Data refreshed September 3, 2026.

Compiled by Nick at Well Water Nerd from public records. How these pages are built

What individual samples found

Each row summarizes every public sample for that contaminant inside South Windsor. Above limit means above the EPA maximum contaminant level; where EPA has no enforceable limit, the row shows a health guideline or nuisance level instead.

ContaminantAbove limitSamplesDetectedMedianHighestLimit
Nitrate
1953 to 2017
3895%3.926210 mg/L
EPA limit
Arsenic
1988 to 2017
3113%01.810 ug/L
EPA limit
Uranium
2003 to 2017
2938%07.730 ug/L
EPA limit
Fluoride
1953 to 2017
1844%00.34 mg/L
EPA limit
Copper
1953 to 2017
1486%0.0020.0131.3 mg/L
EPA limit
Lead
1988 to 2017
1258%0.0381.1315 ug/L
EPA limit
Iron
1953 to 2017
no limit26100%12.8904300 ug/L
nuisance level
Manganese
1953 to 2017
no limit26100%9.88649300 ug/L
health guideline
Chloride
1953 to 2017
no limit26100%36.8875250 mg/L
nuisance level
Sodium
1954 to 2017
no limit24100%28.848020 mg/L
health guideline

Sampled fewer than 10 times, too few to summarize: Radium (226 + 228) (6).

Over time

Share of samples above the limit by period. A cell needs ten samples to show; a comparison needs twenty in each period. Later periods sample fewer wells, and often the ones already known to have a problem.

Contaminantbefore 20002000s2010s2020s
Nitrate36%14 samples19%16 samplesn/an/a

Closer than the town

See the sampled wells near your address

The same records, drawn around one point: which wells within a few miles were sampled and what they found, how deep the wells next to you were drilled, and any leaking tank or cleanup site within a mile.

Check my address

What this means

The contaminants most often above their limit here are nitrate (24% of 38 samples). A well next door can differ sharply from yours because bedrock fractures, well depth and plumbing all matter, so these rates describe the area, not your tap.

Iron, Manganese, and Chloride are widespread in local groundwater. They are mainly a staining and taste problem, but high manganese also carries a health advisory for infants.

What to test for in South Windsor

  1. 1
    Nitrate
    24% of 38 local samples were above the limit.
  2. 2
    Coliform bacteria
    Recommended for every private well, every year.
  3. 3
    Iron
    Detected in 100% of local samples.
  4. 4
    Manganese
    Detected in 100% of local samples.
  5. 5
    Chloride
    Detected in 100% of local samples.
  6. 6
    Copper
    Detected in 86% of local samples.
  7. 7
    Volatile organic compounds (VOCs)
    47 leaking underground storage tank sites on record locally.

Test your South Windsor well for nitrate, coliform bacteria and iron

Certified lab analysis of your own tap water, bottles and prepaid return shipping included. The Essential well panel covers arsenic, uranium, nitrate, lead, copper, manganese, iron, sodium and bacteria; radon and PFAS are add-ons.

Order the Tap Score well water test kit, from $209Already tested? Upload the report

Just want bacteria checked first? Tap Score coliform and E. coli test, $99. Coliform and E. coli are the tests every well needs every year.

Want a quick look before paying for a lab? Home well water test strips on Amazon check hardness, iron, pH and nitrate in minutes. They are a screen, not a result: arsenic, bacteria, uranium and PFAS need a certified lab.

Affiliate links: the merchant pays us a commission and the price is the same for you. It does not change what the data above says. As an Amazon Associate we earn from qualifying purchases.

Where to get a well tested in Connecticut: certified labs, state programs and prices.

Already have results back? Get your lab report read against the South Windsor numbers, $29. Every line explained, ranked by what matters, with the fix for each.

The rock under South Windsor

Early Mesozoic basin aquifers

Sandstone. Sandstone wells draw from pore space in the rock and tend to be dependable. Iron, manganese and hardness are common, and some sandstones carry arsenic or radium, so a first test should include both.

Classification from the USGS Principal Aquifers of the United States (national map, 2003 edition, GIS release 2015), read at the town centroid. A single well can sit in a different unit, especially near a boundary.

Official help in Connecticut

Two places to start that are not selling anything: the state program that answers private well questions, and its list of labs certified to run drinking water tests. A certified lab is the difference between a result you can act on and a number.

Contamination sources on record in South Windsor

CT DEEP contaminated sites and landfills records 47 leaking underground storage tank sites and 1 reported spill or release in South Windsor, among 141 regulated sites in total. Groundwater does not follow property lines, so a well within a few hundred feet of one of these is worth testing for what that site could release.

47
leaking underground storage tank sitesGasoline and heating oil that leaked from tanks move through groundwater as benzene, MTBE and other volatile organic compounds.
1
reported spill or releaseMost spills are fuel; a few are solvents or chemicals that reach the water table.
2
lined landfills and transfer facilities
91
other remediation projects

Treatment that fits the local profile

Nitrate

Point-of-use reverse osmosis; Anion exchange; Distillation

Systems we would look at first

Some links below are affiliate links. If you buy through one, the merchant pays us a commission at no extra cost to you. It does not change which products we list or what the data says.

For nitrate

Under-sink reverse osmosis system

under-sink or countertop, about $300

Look for NSF/ANSI 58 certification listing the contaminant you need removed.

For nitrate

Aquasana SmartFlow reverse osmosis

under-sink or countertop, about $225

Certified to NSF/ANSI 58 and 53 to reduce arsenic (96%, pentavalent), fluoride (90%), lead (99%), nitrate, nitrite and PFOA/PFOS at the kitchen tap, with a remineralizer.

Free, no obligation

Get on the list for a free in-home water test in South Windsor

No water treatment company serves South Windsor through Well Water Nerd yet. We are signing licensed companies on county by county: they test at your tap for free, walk you through the numbers, and quote treatment only if something needs fixing. Leave your details and you are first in line. Nothing is shared until a company joins for South Windsor, and you get an email naming it first.

What are you worried about?

The test is free and there is no obligation. No company is named yet; your details stay with us until one joins for your area, and we log the time and address of this request.

Common questions

Is there arsenic in well water in South Windsor?

Arsenic was detected in 13% of 31 public well samples in South Windsor, and 0% were above the EPA limit of 10 ug/L. Arsenic has no taste or smell; a lab test is the only way to know your level.

How often should I test a private well in South Windsor?

Test for bacteria and nitrate every year. Test once for arsenic, uranium, radon, fluoride, manganese and PFAS, then again every three to five years or after any change in taste, color, or plumbing.

Towns near South Windsor

Closest first. Groundwater does not stop at a line on a map, so the next town over is a fair second opinion.

Want the numbers themselves? Download the Connecticut dataset as CSV, every county and town, with the sources named.

Sources

  • USGS Water Quality Portal: 212 samples in South Windsor. Data from the Water Quality Portal, a service of USGS, EPA and USDA; groundwater samples collected by USGS and cooperators. Retrieved September 3, 2026.
  • Connecticut DPH and USGS arsenic and uranium survey: 38 samples in South Windsor. Arsenic and uranium in 674 private bedrock wells sampled by the Connecticut Department of Public Health with the U.S. Geological Survey, 2013 to 2015. Retrieved .
  • CT DEEP contaminated sites and landfills: 141 regulated sites located in South Windsor. Contaminated or potentially contaminated sites and solid waste landfills from the Connecticut Department of Energy and Environmental Protection. Retrieved September 16, 2026.

Non-detects count as samples and are treated as zero when computing medians. Exactly at the limit counts as not above it. A sample belongs to the town containing the well's reported coordinates.